A dosimetric comparison of volumetric modulated arc therapy (VMAT) and non-coplanar intensity modulated radiotherapy (IMRT) for nasal cavity and paranasal sinus cancer

被引:21
|
作者
Jeong, Yuri [1 ]
Lee, Sang-wook [1 ]
Kwak, Jungwon [1 ]
Cho, Ilsung [1 ]
Yoon, Sang Min [1 ]
Kim, Jong Hoon [1 ]
Park, Jin-hong [1 ]
Choi, Eun Kyung [1 ]
Song, Si Yeol [1 ]
Kim, Young Seok [1 ]
Kim, Su Ssan [1 ]
Joo, Ji Hyeon [1 ]
Ahn, Seung Do [1 ]
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiat Oncol, Seoul 138736, South Korea
来源
RADIATION ONCOLOGY | 2014年 / 9卷
关键词
Paranasal sinus cancer; Nasal cavity cancer; Volumetric modulated arc therapy; Non-coplanar intensity modulated radiotherapy; Planning target volume; Organs at risk; 3-DIMENSIONAL CONFORMAL RADIOTHERAPY; SIMULTANEOUS INTEGRATED BOOST; DELIVERY TIME; RADIATION-THERAPY; SINGLE-ARC; TUMOR-CONTROL; NECK-CANCER; IN-VIVO; CARCINOMAS; IMPACT;
D O I
10.1186/1748-717X-9-193
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: To compare dosimetric parameters of volumetric modulated arc therapy (VMAT) and non-coplanar intensity modulated radiotherapy (IMRT) for nasal cavity and paranasal sinus cancer with regard to the coverage of planning target volume (PTV) and the sparing of organs at risk (OAR). Methods: Ten patients with nasal cavity or paranasal sinus cancer were re-planned by VMAT (two-arc) plan and non-coplanar IMRT (7-, 11-, and 15-beam) plans. Planning objectives were to deliver 60 Gy in 30 fractions to 95% of PTV, with maximum doses (D-max) of <50 Gy to the optic nerves, optic chiasm, and brainstem, <40 Gy to the eyes and <10 Gy to the lenses. The target mean dose (D-mean) to the parotid glands was <25 Gy, and no constraints were applied to the lacrimal glands. Planning was optimized to minimized doses to OAR without compromising coverage of the PTV. VMAT and three non-coplanar IMRT (7-, 11-, and 15-beam) plans were compared using the heterogeneity and conformity indices (HI and CI) of the PTV, D-max and D-mean of the OAR, treatment delivery time, and monitor units (MUs). Results: The HI and CI of VMAT plan were superior to those of the 7-, 11-, and 15-beam non-coplanar IMRT. VMAT and non-coplanar IMRT (7-, 11-, and 15-beam) showed equivalent sparing effects for the optic nerves, optic chiasm, brainstem, and parotid glands. For the eyes and lenses, VMAT achieved equivalent or better sparing effects when compared with the non-coplanar IMRT plans. VMAT showed lower MUs and reduced treatment delivery time when compared with non-coplanar IMRT. Conclusions: In 10 patients with nasal cavity or paranasal sinus cancer, a VMAT plan provided better homogeneity and conformity for PTV than non-coplanar IMRT plans, with a shorter treatment delivery time, while achieving equal or better OAR-sparing effects and using fewer MUs.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Dual Arc Volumetric-modulated Arc Radiotherapy (VMAT) of Nasopharyngeal Carcinomas: A Simultaneous Integrated Boost Treatment Plan Comparison with Intensity-modulated Radiotherapies and Single Arc VMAT
    Lee, T. -F.
    Ting, H. -M.
    Chao, R-J.
    Fang, F. -M.
    CLINICAL ONCOLOGY, 2012, 24 (03) : 196 - 207
  • [42] Monitoring of mechanical errors and their dosimetric impact throughout the course of non-coplanar continuous volumetric-modulated arc therapy
    Hirashima, Hideaki
    Nakamura, Mitsuhiro
    Miyabe, Yuki
    Uto, Megumi
    Nakamura, Kiyonao
    Mizowaki, Takashi
    RADIATION ONCOLOGY, 2018, 13
  • [43] Dosimetric and efficiency comparison of high-dose radiotherapy for esophageal cancer: volumetric modulated arc therapy versus fixed-field intensity-modulated radiotherapy
    Lin, C. -Y.
    Huang, W. -Y.
    Jen, Y. -M.
    Chen, C. -M.
    Su, Y. -F.
    Chao, H. -L.
    Lin, C. -S.
    DISEASES OF THE ESOPHAGUS, 2014, 27 (06) : 585 - 590
  • [44] Volumetric modulated arc therapy: a dosimetric comparison with dynamic IMRT and step-and-shoot IMRT
    Raina, Payal
    Singh, Sudha
    Tudu, Rajanigandha
    Singh, Rashmi
    Kumar, Anup
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2020, 19 (04) : 393 - 398
  • [45] Dosimetric impact of dental metallic crown on intensity-modulated radiotherapy and volumetric-modulated arc therapy for head and neck cancer
    Kamomae, Takeshi
    Itoh, Yoshiyuki
    Okudaira, Kuniyasu
    Nakaya, Takayoshi
    Tomida, Masashi
    Miyake, Yoshikazu
    Oguchi, Hiroshi
    Shiinoki, Takehiro
    Kawamura, Mariko
    Yamamoto, Noriyuki
    Naganawa, Shinji
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (01): : 234 - 245
  • [46] Dosimetric comparison of intensity-modulated radiotherapy and volumetric-modulated arc radiotherapy in patients with prostate cancer: a meta-analysis
    Ren, Wenting
    Sun, Chao
    Lu, Ningning
    Xu, Yingjie
    Han, Fei
    Liu, Yue Ping
    Dai, Jianrong
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (06): : 254 - 262
  • [47] Intensity-modulated radiotherapy and hypofractionated volumetric modulated arc therapy for elderly patients with breast cancer: comparison of acute and late toxicities
    Fiorentino, Alba
    Gregucci, Fabiana
    Mazzola, Rosario
    Figlia, Vanessa
    Ricchetti, Francesco
    Sicignano, Gianluisa
    Giajlevra, Niccolo
    Ruggieri, Ruggero
    Fersino, Sergio
    Naccarato, Stefania
    Massocco, Alberto
    Corradini, Stefanie
    Alongi, Filippo
    RADIOLOGIA MEDICA, 2019, 124 (04): : 309 - 314
  • [48] A fast radiotherapy paradigm for anal cancer with volumetric modulated arc therapy (VMAT)
    Florian Stieler
    Dirk Wolff
    Frank Lohr
    Volker Steil
    Yasser Abo-Madyan
    Friedlieb Lorenz
    Frederik Wenz
    Sabine Mai
    Radiation Oncology, 4
  • [49] Advancing Precision in Post-mastectomy Chest Wall Radiotherapy: A Comparative Dosimetric Analysis of Volumetric-Modulated Arc Therapy (VMAT) and Intensity-Modulated Radiotherapy (IMRT) Based on Institutional Experience
    Mishra, Shiv S.
    Nanda, Siddhartha
    Ahirwar, Manish K.
    Simran
    Rath, Swaroopa M.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (05)
  • [50] Single arc volumetric-modulated arc therapy is sufficient for nasopharyngeal carcinoma: a dosimetric comparison with dual arc VMAT and dynamic MLC and step-and-shoot intensity-modulated radiotherapy
    Zhong-Hua Ning
    Jin-Ming Mu
    Jian-Xue Jin
    Xiao-Dong Li
    Qi-Lin Li
    Wen-Dong Gu
    Jin Huang
    Yang Han
    Hong-Lei Pei
    Radiation Oncology, 8