Functional MRI of the kidney

被引:88
作者
Grenier, N
Basseau, F
Ries, M
Tyndal, B
Jones, R
Moonen, C
机构
[1] Univ Bordeaux 2, CNRS, UMR 5536, F-33076 Bordeaux, France
[2] Grp Hosp Pellegrin, Serv Radiol, F-33076 Bordeaux, France
来源
ABDOMINAL IMAGING | 2002年 / 28卷 / 02期
关键词
kidney; functional studies; MR imacing; glomerular filtration; contrast media;
D O I
10.1007/s00261-001-0183-8
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Functional MR imaging of the kidney has a great potential of development because the functional parameters. which can be approached noninvasively. are multiple: glomerular filtration, tubular concentration and transit, blood volume and perfusion, diffusion, and oxygenation. Until now, its limitations in clinical applications are due to the difficulties in obtaining reproducible and reliable information in this mobile organ and. sometimes, in understanding the physiologic substrate of the signal changes observed. These approaches require either endogeneous contrast agents. such as water protons (for perfusion and diffusion) or deoxyhemogobin (for oxgenation), or exogeneous contrast agents such as gadolinium chelates (for filtration and perfusion) or iron oxide particles (for Derfusion). Clinical validation of these methods and evaluation of their clinical impact are now worthwhile before diffusing them in clinical practice.
引用
收藏
页码:164 / 175
页数:12
相关论文
共 75 条
  • [31] MR assessment of iodinated contrast-medium-induced nephropathy in rats using ultrasmall particles of iron oxide
    Laissy, JP
    Benderbous, S
    Idee, JM
    Beaufils, H
    SchoumanClaeys, E
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (01): : 164 - 170
  • [32] Angiotensin-converting enzyme inhibitor-enhanced phase-contrast MR imaging to measure renal artery velocity waveforms in patients with suspected renovascular hypertension
    Lee, VS
    Rofsky, NM
    Ton, AT
    Johnson, G
    Krinsky, GA
    Weinreb, JC
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (02) : 499 - 508
  • [33] Renal artery velocity mapping with MR imaging
    Maier, SE
    Scheidegger, MB
    Liu, KC
    Schneider, E
    Bollinger, A
    Boesiger, P
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (06): : 669 - 676
  • [34] MATTHAEI D, 1985, LANCET, V2, P893
  • [35] MULLER MF, 1994, RADIOLOGY, V193, P711
  • [36] Namimoto T, 1999, JMRI-J MAGN RESON IM, V9, P832, DOI 10.1002/(SICI)1522-2586(199906)9:6<832::AID-JMRI10>3.0.CO
  • [37] 2-1
  • [38] Measurement of Gd-DTPA dialysis clearance rates by using a look-locker imaging technique
    Niendorf, ER
    Santyr, GE
    Brazy, PC
    Grist, TM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) : 571 - 578
  • [39] Rapid in vivo measurement of single-kidney extraction fraction and glomerular filtration rate with MR imaging
    Niendorf, ER
    Grist, TM
    Lee, FT
    Brazy, PC
    Santyr, GE
    [J]. RADIOLOGY, 1998, 206 (03) : 791 - 798
  • [40] Rapid measurement of Gd-DTPA extraction fraction in a dialysis system using echo-planar imaging
    Niendorf, ER
    Grist, TM
    Frayne, R
    Brazy, PC
    Santyr, GE
    [J]. MEDICAL PHYSICS, 1997, 24 (12) : 1907 - 1913