An aortic balloon catheter incorporating a conduit for percutaneous cardiopulmonary support

被引:0
作者
Watari, M [1 ]
Fukunaga, S [1 ]
Hirai, S [1 ]
Orihashi, K [1 ]
Sueda, T [1 ]
Matsuura, Y [1 ]
机构
[1] Hiroshima Univ, Sch Med, Dept Surg 1, Minami Ku, Hiroshima 734, Japan
关键词
intraaortic balloon pumping; percutaneous cardiopulmonary support; brain damage; cerebral protection; circulatory support;
D O I
10.1046/j.1525-1594.1998.05083.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Circulatory support using both intraaortic balloon pumping (IABP) and percutaneous cardiopulmonary support (PCPS) can improve general hemodynamics; however, sometimes brain damage occurs caused by hypoperfusion. Such cerebral hypoperfusion is likely to be caused by PCPS when applying the conventional femoral cannulation, We have developed a new IABP catheter which incorporates a conduit for PCPS with an outlet at the catheter tip, the goal of which is the improvement of cerebral perfusion. The hemodynamic characteristics of this new IABP catheter were compared with those of the conventional combination of IABP and PCPS. Studies were performed by mock test using a pulsatile artificial heart, a polyvinyl chloride tube acted as the aorta with 2 branches at the proximal and distal portions representing the upper and lower portions of the body. The IABP balloon was positioned between the 2 branches, and changes in now at the 2 branches were examined at varying PCPS flow rates. Flow in the proximal branch using the new device was greater than it was using the conventional PCPS device, We conclude that cerebral perfusion could be improved with the use of this new special IABP catheter.
引用
收藏
页码:148 / 150
页数:3
相关论文
共 7 条
[1]   THE ROLE OF INTRA-AORTIC BALLOON COUNTERPULSATION IN PATIENTS UNDERGOING PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY [J].
ALCAN, KE ;
STERTZER, SH ;
WALLSH, E ;
DEPASQUALE, NP ;
BRUNO, MS .
AMERICAN HEART JOURNAL, 1983, 105 (03) :527-530
[2]   EVALUATION OF THE PULSATILITY OF A NEW PULSATILE LEFT-VENTRICULAR ASSIST DEVICE - THE INTEGRATED CARDIOASSIST CATHETER - IN DOGS [J].
IDE, H ;
YAMAGUCHI, A ;
INO, T ;
ADACHI, H ;
MIZUHARA, A ;
KAWAHITO, K ;
MATSUMOTO, H ;
FUJIMASA, I .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1994, 107 (02) :569-575
[3]  
Minatoya K, 1995, Nihon Kyobu Geka Gakkai Zasshi, V43, P398
[4]   EMERGENCY CARDIOPULMONARY BYPASS SUPPORT IN PATIENTS WITH CARDIAC-ARREST CAUSED BY MYOCARDIAL-INFARCTION [J].
MORI, Y ;
UENO, K ;
HATTORI, A ;
KIM, T ;
AOYAMA, T ;
SEGAWA, T ;
MIMOTO, H ;
TOMITA, R ;
TANAKA, T ;
MORI, N .
ARTIFICIAL ORGANS, 1994, 18 (09) :698-701
[5]   PERCUTANEOUS INITIATION OF CARDIOPULMONARY BYPASS [J].
PHILLIPS, SJ ;
BALLENTINE, B ;
SLONINE, D ;
HALL, J ;
VANDEHAAR, J ;
KONGTAHWORN, C ;
ZEFF, RH ;
SKINNER, JR ;
RECKMO, K ;
GRAY, D .
ANNALS OF THORACIC SURGERY, 1983, 36 (02) :223-225
[6]   PERCUTANEOUS CARDIOPULMONARY BYPASS - APPLICATION AND INDICATION FOR USE [J].
PHILLIPS, SJ ;
ZEFF, RH ;
KONGTAHWORN, C ;
SKINNER, JR ;
TOON, RS ;
GRIGNON, A ;
KENNERLY, RM ;
WICKEMEYER, W ;
IANNONE, LA .
ANNALS OF THORACIC SURGERY, 1989, 47 (01) :121-123
[7]  
Sato M., 1993, Japanese Journal of Artificial Organs, V22, P639