The effect of disinfectants on dimensional stability of addition and condensation silicone impressions

被引:19
作者
Sinobad, Tamara [1 ]
Obradovic-Djuricic, Kosovka [1 ]
Nikolic, Zoran [3 ]
Dodic, Slobodan [1 ]
Lazic, Vojkan [1 ]
Sinobad, Vladimir [2 ]
Jesenko-Rokvic, Aleksandra [4 ]
机构
[1] Univ Belgrade, Fac Med Dent, Clin Dent Prosthet, Belgrade 11000, Serbia
[2] Univ Belgrade, Fac Med Dent, Clin Maxillofacial Surg, Belgrade 11000, Serbia
[3] Univ Belgrade, Fac Phys, Belgrade 11000, Serbia
[4] Univ Belgrade, Fac Pharm, Belgrade 11000, Serbia
关键词
dental impression materials; silicones; disinfectans; dental prosthesis; DENTAL IMPRESSIONS; ACCURACY; IMMERSION; POLYETHER;
D O I
10.2298/VSP120709037S
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Aim. Dimensional stability and accuracy of an impression after chemical disinfection by immersion in disinfectants are crucial for the accuracy of final prosthetic restorations. The aim of this study was to assess the deformation of addition and condensation silicone impressions after disinfection in antimicrobial solutions. Methods. A total of 120 impressions were made on the model of the upper arch representing three full metal-ceramic crown preparations. Four impression materials were used: two condensation silicones (Oranwash L - Zhermack and Xantopren L Blue - Heraeus Kulzer) and two addition silicones (Elite H-D + regular body Zhermack and Flexitime correct flow Heraeus Kulzer). After removal from the model the impressions were immediately immersed in appropriate disinfectant (glutaraldehyde, benzalkonium chloride - Sterigum and 5.25% NaOCl) for a period of 10 min. The control group consisted of samples that were not treated with disinfectant solution. Consecutive measurements of identical impressions were realized with a Canon G9 (12 megapixels, 2 fps, 6x/24x), and automated with a computer Asus Lamborghini VX-2R Intel C2D 2.4 GHz, by using Remote Capture software package, so that time-depending series of images of the same impression were obtained. Results. The dimensional changes of all the samples were significant both as a function of time and the applied disinfectant. The results show significant differences of the obtained dimensional changes between the group of condensation silicones and the group of addition silicones for the same time, and the same applied disinfectant (p = 0.026, F = 3.95). Conclusion. The greatest dimensional changes of addition and condensation silicone impressions appear in the first hour after their separation from the model.
引用
收藏
页码:251 / 258
页数:8
相关论文
共 38 条
[1]   Effect of disinfectant agents on dimensional stability of elastomeric impression materials [J].
Adabo, GL ;
Zanarotti, E ;
Fonseca, RG ;
Cruz, CAD .
JOURNAL OF PROSTHETIC DENTISTRY, 1999, 81 (05) :621-624
[2]   Disinfection of dental impressions - compliance to accepted standards [J].
Almortadi, N. ;
Chadwick, R. G. .
BRITISH DENTAL JOURNAL, 2010, 209 (12) :607-611
[3]  
[Anonymous], 1996, J AM DENT ASSOC, V127, P672
[4]  
[Anonymous], 1977, J Am Dent Assoc, V94, P733
[5]  
[Anonymous], 2000, 42832000 ISO
[6]  
Carvalhal Cintia Iara Oda, 2011, J Contemp Dent Pract, V12, P252
[7]   LONG-TERM DIMENSIONAL STABILITY OF 3 CURRENT ELASTOMERS [J].
CLANCY, JMS ;
SCANDRETT, FR ;
ETTINGER, RL .
JOURNAL OF ORAL REHABILITATION, 1983, 10 (04) :325-333
[8]   The effect of temperature changes on the dimensional stability of polyvinyl siloxane and polyether impression materials [J].
Corso, M ;
Abanomy, A ;
Di Canzio, J ;
Zurakowski, D ;
Morgano, SM .
JOURNAL OF PROSTHETIC DENTISTRY, 1998, 79 (06) :626-631
[9]  
DeLong R, 2001, J Prosthodont, V10, P78, DOI 10.1111/j.1532-849X.2001.00078.x
[10]   Disinfection of Bacterially Contaminated Hydrophilic PVS Impression Materials [J].
Estafanous, Emad Wadie ;
Palenik, Charles John ;
Platt, Jeffrey A. .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2012, 21 (01) :16-21