Comparative Study of a Series of 99mTc(CO)3 Mannosylated Dextran Derivatives for Sentinel Lymph Node Detection

被引:3
|
作者
Papasavva, Afroditi [1 ]
Shegani, Antonio [1 ]
Kiritsis, Christos [1 ]
Roupa, Ioanna [1 ]
Ischyropoulou, Myrto [1 ]
Makrypidi, Konstantina [1 ]
Pilatis, Irineos [2 ]
Loudos, George [2 ]
Pelecanou, Maria [3 ]
Papadopoulos, Minas [1 ]
Pirmettis, Ioannis [1 ]
机构
[1] NCSR Demokritos, Inst Nucl & Radiol Sci & Technol, Energy & Safety, Athens 15310, Greece
[2] NCSR Demokritos, BIOEMTECH Labs, Lefkippos Att Technol Pk, Athens 15310, Greece
[3] NCSR Demokritos, Inst Biosci & Applicat, Athens 15310, Greece
来源
MOLECULES | 2021年 / 26卷 / 16期
关键词
sentinel lymph node; dextran; mannose; cysteine; technetium-99m; SPECT imaging; BREAST-CANCER; AGENT; BEARING;
D O I
10.3390/molecules26164797
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Sentinel lymph node detection (SLND) is rapidly entering common practice in the management of patients with tumors. The introduction of mannose molecules to Tc-99m-labeled dextrans, so far, showed that the sentinel node could trap these agents due to their recognition by the mannose receptors of lymph node macrophages. The current study aimed to synthesize, characterize, and biologically evaluate a series of mannosylated dextran derivatives labeled with Tc-99m for potential use in SLND. The compounds were designed to have a dextran with a molecular weight of 10-500 kDa as a backbone, S-derivatized cysteines, efficient SNO chelators, and mannose moieties for binding to mannose receptors. They were successfully synthesized, thoroughly characterized using NMR techniques, and labeled with the fac-[Tc-99m(CO)(3)](+) synthon. Labeling with high yields and radiochemical purities was achieved with all derivatives. In vivo biodistribution and imaging studies demonstrated high uptake in the first lymph node and low uptakes in the following node and confirmed the ability to visualize the SLN. Among the compounds studied, Tc-99m-D75CM demonstrated the most attractive biological features, and in combination with the high radiochemical yield and stability of the compound, its further evaluation as a new radiopharmaceutical for sentinel lymph node detection was justified.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] New 99mTc(CO)3 Mannosylated Dextran Bearing S-Derivatized Cysteine Chelator for Sentinel Lymph Node Detection
    Pirmettis, I.
    Arano, Y.
    Tsotakos, T.
    Okada, K.
    Yamaguchi, A.
    Uehara, T.
    Morais, M.
    Correia, J. D. G.
    Santos, I.
    Martins, M.
    Pereira, S.
    Triantis, C.
    Kyprianidou, P.
    Pelecanou, M.
    Papadopoulos, M.
    MOLECULAR PHARMACEUTICS, 2012, 9 (06) : 1681 - 1692
  • [2] Mannosylated Dextran Derivatives Labeled with fac-[M(CO)3]+ (M=99mTc, Re) for Specific Targeting of Sentinel Lymph Node
    Morais, Mauricio
    Subramanian, Suresh
    Pandey, Usha
    Samuel, Grace
    Venkatesh, Meera
    Martins, Manuel
    Pereira, Sergio
    Correia, Joao D. G.
    Santos, Isabel
    MOLECULAR PHARMACEUTICS, 2011, 8 (02) : 609 - 620
  • [3] Comparative biological evaluation of two [99mTc(CO)3]-dextran pyrazolyl mannose conjugates developed for use in sentinel lymph node detection
    Subramanian, S.
    Pandey, U.
    Morais, M.
    Correia, J. D. G.
    Santos, I.
    Samuel, G.
    QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 58 (02): : 216 - 223
  • [4] Injection Site Radioactivity of 99mTc-Labeled Mannosylated Dextran for Sentinel Lymph Node Mapping
    Yamaguchi, Aiko
    Hanaoka, Hirofumi
    Pirmettis, Ioannis
    Uehara, Tomoya
    Tsushima, Yoshito
    Papadopoulos, Minas
    Arano, Yasushi
    MOLECULAR PHARMACEUTICS, 2015, 12 (02) : 514 - 519
  • [5] Studies Toward the Biological Efficacy of 99mTc-Labeled Dextran-Cysteine-Mannose ([99mTc(CO)3]DCM20) for Sentinel Lymph Node Detection
    Subramanian, Suresh
    Pandey, Usha
    Papadopoulos, Minas
    Pirmettis, Ioannis
    Venkatesh, Meera
    Samuel, Grace
    CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2012, 27 (06) : 365 - 370
  • [6] Scintigraphic sentinel node detection in breast cancer patients:: paired and blinded comparison of 99mTc dextran 500 and 99mTc phytate
    Masiero, PR
    Xavier, NL
    Spiro, BL
    Detanico, MF
    Xavier, MD
    Pinto, ALA
    NUCLEAR MEDICINE COMMUNICATIONS, 2005, 26 (12) : 1087 - 1091
  • [7] A preclinical study of prostate sentinel lymph node mapping with [99mTC]diethylenetetramine pentaacetic acid-mannosyl-dextran
    Salem, CE
    Hoh, CK
    Wallace, AM
    Vera, DR
    JOURNAL OF UROLOGY, 2006, 175 (02): : 744 - 748
  • [8] Sentinel node detection with 99mTc Dextran and follow up in malignant skin lesions.
    Neubauer, SE
    Mena, I
    Gomez, L
    Schwartz, R
    Iglesis, R
    Leon, A
    Acevedo, JC
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 292P - 292P
  • [9] [99mTc]MAG3-mannosyl-dextran:: a receptor-binding radiopharmaceutical for sentinel node detection
    Vera, DR
    Wallace, AM
    Hoh, CK
    NUCLEAR MEDICINE AND BIOLOGY, 2001, 28 (05) : 493 - 498
  • [10] Subareolar injection of 99mTc facilitates sentinel lymph node identification
    Tuttle, TM
    Colbert, M
    Christensen, R
    Ose, KJ
    Jones, T
    Wetherille, R
    Friedman, J
    Swenson, K
    McMasters, KM
    ANNALS OF SURGICAL ONCOLOGY, 2002, 9 (01) : 77 - 81