Agreement between methods of measurement with multiple observations per individual

被引:1486
作者
Bland, J. Martin [1 ]
Altman, Douglas G.
机构
[1] York Univ, Dept Hlth Sci, York YO10 5DD, N Yorkshire, England
[2] Ctr Stat Med, Oxford, England
关键词
agreement; limits; measurement; multiple;
D O I
10.1080/10543400701329422
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Limits of agreement provide a straightforward and intuitive approach to agreement between different methods for measuring the same quantity. When pairs of observations using the two methods are independent, i.e., on different subjects, the calculations are very simple and straightforward. Some authors collect repeated data, either as repeated pairs of measurements on the same subject, whose true value of the measured quantity may be changing, or more than one measurement by one or both methods of an unchanging underlying quantity. In this paper we describe methods for analysing such clustered observations, both when the underlying quantity is assumed to be changing and when it is not.
引用
收藏
页码:571 / 582
页数:12
相关论文
共 8 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]   Lack of agreement between bioimpedance and continuous thermodilution measurement of cardiac output in intensive care unit patients [J].
Ben N Barry ;
Abhiram Mallick ;
Andrew R Bodenham ;
Michael Vucevic .
Critical Care, 1 (2)
[3]   Gradient-Based Algorithms for Block-Oriented MAP Estimation of Motion and Application to Motion-Compensated Temporal Interpolation [J].
Bergeron, Claude ;
Dubois, Eric .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS FOR VIDEO TECHNOLOGY, 1991, 1 (01) :72-85
[4]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]  
BLAND JM, 1992, CURRENT CONTENT 1005, V40, P8
[7]   LACK OF AGREEMENT BETWEEN MEASUREMENT OF EJECTION FRACTION BY IMPEDANCE CARDIOGRAPHY VERSUS RADIONUCLIDE VENTRICULOGRAPHY [J].
BOWLING, LS ;
SAGEMAN, WS ;
OCONNOR, SM ;
COLE, R ;
AMUNDSON, DE .
CRITICAL CARE MEDICINE, 1993, 21 (10) :1523-1527
[8]   The most-cited statistical papers [J].
Ryan, TP ;
Woodall, WH .
JOURNAL OF APPLIED STATISTICS, 2005, 32 (05) :461-474