Energy-saving owing to using PCM into buildings: Considering of hot and cold climate region

被引:46
作者
Dehkordi, Bahman Soleiman [1 ]
Afrand, Masoud [1 ]
机构
[1] Islamic Azad Univ, Najafabad Branch, Dept Mech Engn, Najafabad, Iran
关键词
PCM; Building; Energy Consumption; Annual analysis; PHASE-CHANGE MATERIAL; THERMAL INERTIA; HEAT-TRANSFER; SYSTEM; PERFORMANCE; INSULATION; REDUCTION; DESIGN; WIND; FINS;
D O I
10.1016/j.seta.2022.102112
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
From 2010 to 2020, energy consumption in the Middle East increased by 24.2%. Because this region, in step with other regions of the world, has suffered from the phenomenon of global warming, but at a higher rate. At the same time, the share of renewable energy in this period has not changed much. We examined PCM effectiveness for four hot regions along with four cold regions. The results showed that the effect of PCM on heat exchange in winter and summer can be quite the opposite. Therefore, the appropriate PCM was selected based on annual analysis. Annual calculations show that for hot regions, the maximum energy-saving was obtained for PCM-24. In these zones, the maximum energy saving was within the range of 19-30 kWh per square meter of building floor. For cold climates, PCM-22 had the best performance. In these regions, the saving energy was in the range of 30-55 kWh/m(2). It was found that if PCM is not selected properly, it can increase the building energy demand. PCM thickness intensifies the positive or negative effects of PCM. If PCM reduces heat exchange (positive effect), it intensifies as the PCM thickness increases. Conversely, if PCM increases energy consumption, increasing PCM thickness will make it worse.
引用
收藏
页数:14
相关论文
共 47 条
[41]   A dynamic multi-objective optimization procedure for water cooling of a photovoltaic module [J].
Shahverdian, Mohammad Hassan ;
Sohani, Ali ;
Sayyaadi, Hoseyn ;
Samiezadeh, Saman ;
Doranehgard, Mohammad Hossein ;
Karimi, Nader ;
Li, Larry K. B. .
SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2021, 45
[42]   The cost benefit analysis and potential emission reduction evaluation of applying wall insulation for buildings in Malaysia [J].
Shekarchian, M. ;
Moghavvemi, M. ;
Rismanchi, B. ;
Mahlia, T. M. I. ;
Olofsson, T. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (07) :4708-4718
[43]   Selecting the best nanofluid type for A photovoltaic thermal (PV/T) system based on reliability, efficiency, energy, economic, and environmental criteria [J].
Sohani, Ali ;
Shahverdian, Mohammad Hassan ;
Sayyaadi, Hoseyn ;
Samiezadeh, Saman ;
Doranehgard, Mohammad Hossein ;
Nizetic, Sandro ;
Karimi, Nader .
JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2021, 124 :351-358
[44]   Thermal inertia as an integrative parameter for building performance [J].
Soret, G. M. ;
Vacca, P. ;
Tignard, J. ;
Hidalgo, J. P. ;
Maluk, C. ;
Aitchison, M. ;
Torero, J. L. .
JOURNAL OF BUILDING ENGINEERING, 2021, 33
[45]   Optimal scheduling strategy of district integrated heat and power system with wind power and multiple energy stations considering thermal inertia of buildings under different heating regulation modes [J].
Wang, Dan ;
Zhi, Yun-qiang ;
Jia, Hong-jie ;
Hou, Kai ;
Zhang, Shen-xi ;
Du, Wei ;
Wang, Xu-dong ;
Fan, Meng-hua .
APPLIED ENERGY, 2019, 240 :341-358
[46]   A critical analysis on the energy and exergy performance of photovoltaic/ thermal (PV/T) system: The role of nanofluids stability and synthesizing method [J].
Yazdani, Alireza ;
Aberoumand, Hossein ;
Farhadi, Yousef ;
Ansari, Abolfazl ;
Aberoumand, Sadegh ;
Karimi, Nader ;
Afrand, Masoud ;
Cheraghian, Goshtasp ;
Parsa, Seyed Masoud ;
Ali, Hafiz Muhammad .
SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 51
[47]   Numerical investigation of natural convection behavior of molten PCM in an enclosure having rectangular and tree-like branching fins [J].
Yildiz, Cagatay ;
Arici, Muslum ;
Nizetic, Sandro ;
Shahsavar, Amin .
ENERGY, 2020, 207