Bowel Penetration by Inferior Vena Cava Filters: Feasibility and Safety of Percutaneous Retrieval

被引:12
作者
Joe, Winston B. [1 ]
Larson, Michael L. [2 ]
Madassery, Sreekumar [3 ]
Devane, A. Michael [4 ]
Holly, Brian P. [5 ]
Sing, Ronald F. [6 ]
Rochon, Paul J. [7 ]
Lessne, Mark L. [5 ,8 ]
Aal, Ahmed K. Abdel [2 ]
Gunn, Andrew J. [2 ]
机构
[1] Univ Alabama Birmingham, Sch Med, Birmingham, AL USA
[2] Univ Alabama Birmingham, Dept Radiol, Div Vasc & Intervent Radiol, 619 19th St S, Birmingham, AL 35249 USA
[3] Rush Univ, Med Ctr, Dept Radiol, Sect Intervent Radiol, Chicago, IL USA
[4] Greenville Hlth Syst Univ Med Grp, Dept Radiol, Greenville, SC USA
[5] Johns Hopkins Univ Hosp, Dept Vasc & Intervent Radiol, Baltimore, MD 21287 USA
[6] Carolinas HealthCare Syst, Dept Surg, Charlotte, NC USA
[7] Univ Colorado, Dept Radiol, Div Intervent Radiol, Anschutz Med Campus, Aurora, CO USA
[8] Charlotte Radiol, Vasc & Intervent Specialists, Charlotte, NC USA
关键词
complex filter retrieval; filter penetration; filter retrieval; inferior vena cava filter; ENDOVASCULAR RETRIEVAL; IVC FILTER; GUNTHER TULIP; PERFORATION; CELECT; COMPLICATIONS; MANAGEMENT; REMOVAL; SUCCESS;
D O I
10.2214/AJR.19.21279
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to evaluate the safety and technical feasibility of inferior vena cava filter (IVCF) removal when filter elements penetrate adjacent bowel. MATERIALS AND METHODS. A multicenter retrospective review of IVCF retrievals between 2008 and 2018 was performed. Adult patients with either CT or endoscopic evidence of filter elements penetrating bowel before retrieval were included Technical success of IVCF retrieval was recorded. Patient records were assessed for immediate, 30-day, and 90-day complications after retrieval. RESULTS. Thirty-nine consecutive adult patients (11 men and 28 women; mean age, 51.2 years; age range, 18-81 years) qualified for inclusion. Filter dwell time was a median of 148 days (range, 32-5395 days). No IVCFs were known to have migrated or caused iliocaval thrombosis. Five IVCFs (12.8%) had more than 15 degrees tilt relative to the inferior vena cava (IVC) before retrieval. Three IVCFs (7.7%) had fractured elements identified at the time of retrieval. Mean international normalized ratio (INR) was 1.24 +/- 0.53 (SD), and mean platelet count was 262 +/- 139 x 10(3)/mu L. Ten patients (25.6%) were on antibiotics at the time of retrieval. All 39 I VCFs were successfully retrieved (technical success = 100%). Two patients experienced minor complications in the immediate postprocedural period, which resulted in a minor complication rate of 5.1%. There were no complications (major or minor) identified in any patient at 30 or 90 days after retrieval. The overall major complication rate was 0%. CONCLUSION. Endovascular retrieval of IVCFs with CT evidence of filter elements that have penetrated adjacent bowel is both safe and technically feasible.
引用
收藏
页码:1152 / 1156
页数:5
相关论文
共 27 条
[1]   Inferior Vena Cava Filter Retrieval: Effectiveness and Complications of Routine and Advanced Techniques [J].
Al-Hakim, Ramsey ;
Kee, Stephen T. ;
Olinger, Kristen ;
Lee, Edward W. ;
Moriarty, John M. ;
McWilliams, Justin P. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 25 (06) :933-939
[2]   The indigenous gastrointestinal microflora [J].
Berg, RD .
TRENDS IN MICROBIOLOGY, 1996, 4 (11) :430-435
[3]  
Bond JM, 2017, ANN VASC DIS, V10, P438, DOI 10.3400/avd.cr.17-00020
[4]   Endovascular Retrieval of an Inferior Vena Cava Filter With Simultaneous Caval, Aortic, and Duodenal Perforations [J].
Caldwell, Edward H. ;
Fridley, Todd L. ;
Erb, Edward L. ;
Fleischer, Stephen R. .
VASCULAR AND ENDOVASCULAR SURGERY, 2012, 46 (08) :671-674
[5]  
Clarke K, 2011, PRACT GASTROENTEROL, V35, P44
[6]   Complicated Inferior Vena Cava Filter Retrievals: Associated Factors Identified at Preretrieval CT [J].
Dinglasan, Lu Anne V. ;
Oh, John C. ;
Schmitt, J. Eric ;
Trerotola, Scott O. ;
Shlansky-Goldberg, Richard D. ;
Stavropoulos, S. William .
RADIOLOGY, 2013, 266 (01) :347-354
[7]   Endovascular Removal of Inferior Vena Cava Filters with Arterial Penetration [J].
Duncan, Christopher ;
Trerotola, Scott O. ;
Stavropoulos, S. William .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2018, 29 (04) :486-490
[8]   Perforation of the IVC: Rule Rather Than Exception After Longer Indwelling Times for the Gunther Tulip and Celect Retrievable Filters [J].
Durack, Jeremy C. ;
Westphalen, Antonio C. ;
Kekulawela, Stephanie ;
Bhanu, Shiv B. ;
Avrin, David E. ;
Gordon, Roy L. ;
Kerlan, Robert K. .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 35 (02) :299-308
[9]   Fibrin Cap Disruption: An Adjunctive Technique for Inferior Vena Cava Filter Retrieval [J].
Esparaz, Anthony M. ;
Ryu, Robert K. ;
Gupta, Ramona ;
Resnick, Scott A. ;
Salem, Riad ;
Lewandowski, Robert J. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 23 (09) :1233-1235
[10]  