An accurate method of radiological assessment of acetabular abduction and anteversion angles in three-dimensional reconstruction of multi-slice spiral computed tomography

被引:0
作者
Fan, Xin-Cheng [1 ]
Fan, Wen-Wen [2 ]
Wang, Feng-Yao [3 ]
Yu, Chun-Li [1 ]
Zhu, Hai-Tao [1 ]
Wei, Kai-Bin [1 ]
Ma, Zhen-Bo [4 ]
Liu, Feng [1 ]
机构
[1] Taian Ctr Hosp Shandong Prov, Dept Orthoped, Tai An, Shandong, Peoples R China
[2] Women & Children Hosp Qingdao City, Dept Pediat, Qingdao, Peoples R China
[3] Third Peoples Hosp Qingdao City, Dept Urinary Surg, Qingdao, Peoples R China
[4] Taian Ctr Hosp Shandong Prov, Dept Radiol, Tai An, Shandong, Peoples R China
关键词
Bone anteversion; Tomography; spiral computed; Arthroplasty; TOTAL HIP-ARTHROPLASTY; CT; REPLACEMENT; RADIOGRAPHS; ORIENTATION; OSTEOLYSIS; PLACEMENT; COMPONENT; DESIGN; MOTION;
D O I
10.23736/S1120-4826.16.02147-9
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
BACKGROUND: The characteristics of acetabular abduction angle and anteversion in three dimensions are still unclear. This study aimed to assess the diagnostic values of acetabular abduction angle and anteversion by three-dimensional reconstruction of multi-slice spiral CT (MSCT). METHODS: To verify the reliability and accuracy of the acetabular abduction angle and anteversion by using MSCT, both manual and radiological examinations of pelves (N = 30) and acetabula (N = 60) were included in the study. The manual examination was performed with a protractor and a digital goniometer (Protractor). The radiological examination was performed by using the digital X-ray photography (DR) and MSCT (3D). The pelvic anterior plane (PAP) served as a reference plane throughout the study. RESULTS: No significant difference was found among protractor, DR, and 3D measurement of acetabular abduction angles and anteversion angles [(16.24 +/- 4.74)degrees, (16.44 +/- 4.82)degrees vs. (15.82 +/- 4.62)degrees, P>0.05)]. Comparisons revealed significant positive correlations among protractor, DR, and 3D measurement of acetabular abduction angles and anteversion angles. CONCLUSIONS: Our study shows a new, reliable diagnostic tool for measuring the acetabular abduction angle and anteversion in THA or other hip surgeries.
引用
收藏
页码:41 / 49
页数:9
相关论文
共 26 条
  • [1] Intraoperative pelvic motion in total hip arthroplasty
    Asayama, I
    Akiyoshi, Y
    Naito, M
    Ezoe, M
    [J]. JOURNAL OF ARTHROPLASTY, 2004, 19 (08) : 992 - 997
  • [2] A new method for the measurement of anteversion of the acetabular cup after total hip arthroplasty
    Aydogan M.
    Burç H.
    Saka G.
    [J]. European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (6) : 897 - 903
  • [3] Barrack Robert L, 2003, J Am Acad Orthop Surg, V11, P89
  • [4] Biedermann R, 2005, J BONE JOINT SURG BR, V87B, P762, DOI 10.1302/0301-620X.87B6
  • [5] Bony Impingement Limits Design-related Increases in Hip Range of Motion
    Bunn, Adam
    Colwell, Clifford W., Jr.
    D'Lima, Darryl D.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (02) : 418 - 427
  • [6] Chen Eduard, 2006, Comput Aided Surg, V11, P309, DOI 10.1080/10929080601090516
  • [7] Comparison of a mechanical acetabular alignment guide with computer placement of the socket
    DiGioia, AM
    Jaramaz, B
    Plakseychuk, AY
    Moody, JE
    Nikou, C
    LaBarca, RS
    Levison, TJ
    Picard, F
    [J]. JOURNAL OF ARTHROPLASTY, 2002, 17 (03) : 359 - 364
  • [8] Eddine TA, 2001, SURG RADIOL ANAT, V23, P105
  • [9] Contributions of human tissue analysis to understanding the mechanisms of loosening and osteolysis in total hip replacement
    Gallo, Jiri
    Vaculova, Jana
    Goodman, Stuart B.
    Konttinen, Yrjoe T.
    Thyssen, Jacob P.
    [J]. ACTA BIOMATERIALIA, 2014, 10 (06) : 2354 - 2366
  • [10] In vivo and ex vivo measurement of polyethylene wear in total hip arthroplasty
    Goldvasser, Dov
    Hansen, Viktor J.
    Noz, Marilyn E.
    Maguire, Gerald Q., Jr.
    Zeleznik, Michael P.
    Olivecrona, Henrik
    Bragdon, Charles R.
    Weidenhielm, Lars
    Malchau, Henrik
    [J]. ACTA ORTHOPAEDICA, 2014, 85 (03) : 271 - 275