Experience of total knee arthroplasty using a novel navigation system within the surgical field

被引:9
作者
Niehaus, Richard [1 ,4 ]
Schilter, David [1 ]
Fornaciari, Paolo [2 ]
Weinand, Christian [3 ]
Boyd, Marcus [1 ]
Ziswiler, Marcel [1 ]
Ehrendorfer, Stefan [1 ]
机构
[1] Kantonsspital Uri KSU, Dept Orthopaed Surg, Spitalstr 1, CH-6460 Altdorf, Switzerland
[2] Hop Cantonal Fribourg, HFR Fribourg, Dept Orthopaed Surg, CH-1700 Fribourg, Switzerland
[3] Ernst Moritz Arndt Univ Greifswald, Dietrich Bonhoeffer Klinikum, Dept Plast & Aesthet Surg, D-17033 Neubrandenburg, Germany
[4] Balgrist Univ Hosp, CH-8008 Zurich, Switzerland
关键词
Total knee arthroplasty; TKA; Computer-assisted TICA; iAssist; Knee replacement; Navigated knee; PATIENT SATISFACTION; TIBIAL COMPONENT; ALIGNMENT; REPLACEMENT; PAIN;
D O I
10.1016/j.knee.2016.10.021
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: With the aim of improving component alignment and outcome in total knee arthroplasty (TKA), several computer -assisted devices (CAD) have been developed. Methods: In February 2014, the present unit started to use a new imageless navigation system with accelerometric pods within the surgical field for all primary TICAs: there was no need for optical trackers or cameras. This paper presents the results of the first 72 TKAs using this iAssist system in 71 prospectively collected and retrospectively analyzed patients. It analyzed component positioning in standard and full-length leg x-rays. Results: The mean age of the patients was 70 years (range 52-88). The center of hip, knee and ankle (mechanical axes) deviated on average 0.5 (standard deviation (SD) of 1.8) valgus from the targeted straight alignment. Three TKAs had >3 deviation (i.e. four degree varus, five degree and seven degree valgus). The frontal tibial tray alignment was an average of 89.9 (range 86.4-100.1, SD +/- 2.0) with the target being 90, and the sagittal slope was as targeted at 85.0 (range 78.4-88.8, SD +/- 1.7). Conclusions: This CAD facilitated good mechanical alignment and reproducible accuracy in component positioning. Pods clipped onto cutting jigs within the surgical field provided simple and accurate navigation, with little extra time needed for calibration and no need for optical trackers or pre-operative imaging. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:518 / 524
页数:7
相关论文
共 23 条
[1]  
Australian Orthopaedic Association National Joint Replacement Registry, 2014, HIP KNEE ARTHR ANN R
[2]   The role of pain and function in determining patient satisfaction after total knee replacement - Data from the National Joint Registry for England and Wales [J].
Baker, P. N. ;
van der Meulen, J. H. ;
Lewsey, J. ;
Gregg, P. J. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (07) :893-900
[3]   Tibial component failure mechanisms in total knee arthroplasty [J].
Berend, ME ;
Ritter, MA ;
Meding, JB ;
Faris, PM ;
Keating, EM ;
Redelman, R ;
Faris, GW ;
Davis, KE .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (428) :26-34
[4]   Patient Satisfaction after Total Knee Arthroplasty Who is Satisfied and Who is Not? [J].
Bourne, Robert B. ;
Chesworth, Bert M. ;
Davis, Aileen M. ;
Mahomed, Nizar N. ;
Charron, Kory D. J. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (01) :57-63
[5]   Does Accurate Anatomical Alignment Result in Better Function and Quality of Life? Comparing Conventional and Computer-Assisted Total Knee Arthroplasty [J].
Choong, Peter F. ;
Dowsey, Michelle M. ;
Stoney, James D. .
JOURNAL OF ARTHROPLASTY, 2009, 24 (04) :560-569
[6]  
Delp SL, 1998, CLIN ORTHOP RELAT R, P49
[7]  
EWALD FC, 1989, CLIN ORTHOP RELAT R, P9
[8]  
Gothesen O, 2000, BONE JOINT J B, V96, P609
[9]   What is the optimal alignment of the tibial and femoral components in knee arthroplasty? An overview of the literature [J].
Gromov, Kirill ;
Korchi, Mounim ;
Thomsen, Morten G. ;
Husted, Henrik ;
Troelsen, Anders .
ACTA ORTHOPAEDICA, 2014, 85 (05) :480-487
[10]  
HOFMANN AA, 1991, CLIN ORTHOP RELAT R, P63