Distinguishing between the metabolome and xenobiotic exposome in environmental field samples analysed by direct-infusion mass spectrometry based metabolomics and lipidomics

被引:20
|
作者
Southam, Andrew D. [1 ]
Lange, Anke [2 ]
Al-Salhi, Raghad [3 ]
Hill, Elizabeth M. [3 ]
Tyler, Charles R. [2 ]
Viant, Mark R. [1 ]
机构
[1] Univ Birmingham, Sch Biosci, Birmingham B15 2TT, W Midlands, England
[2] Univ Exeter, Coll Life & Environm Sci, Exeter EX4 4QD, Devon, England
[3] Univ Sussex, Sch Life Sci, Brighton BN1 9QG, E Sussex, England
关键词
Rutilus rutilus; Exposome; Xenometabolome; Endometabolome; Lipidome; WATER TREATMENT WORKS; HIGH-THROUGHPUT; FISH; NMR; IDENTIFICATION; XENOMETABOLOME; TOXICOLOGY; SIGNATURES; EFFLUENTS; DISCOVERY;
D O I
10.1007/s11306-014-0693-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Environmental metabolomics is increasingly used to investigate organismal responses to complex chemical mixtures, including waste water effluent (WWE). In parallel, increasingly sensitive analytical methods are being used in metabolomics studies, particularly mass spectrometry. This introduces a considerable, yet overlooked, challenge that high analytical sensitivity will not only improve the detection of endogenous metabolites in biological specimens but also exogenous chemicals. If these often unknown xenobiotic features are not removed from the "biological" dataset, they will bias the interpretation and could lead to incorrect conclusions about the biotic response. Here we illustrate and validate a novel workflow classifying the origin of peaks detected in biological samples as: endogenous, xenobiotics, or metabolised xenobiotics. The workflow is demonstrated using direct infusion mass spectrometry-based metabolomic analysis of testes from roach exposed to different concentrations of a complex WWE. We show that xenobiotics and their metabolic products can be detected in roach testes (including triclosan, chloroxylenol and chlorophene), and that these compounds have a disproportionately high level of statistical significance within the total (bio)chemical changes induced by the WWE. Overall we have demonstrated that this workflow extracts more information from an environmental metabolomics study of complex mixture exposures than was possible previously.
引用
收藏
页码:1050 / 1058
页数:9
相关论文
共 21 条
  • [1] Distinguishing between the metabolome and xenobiotic exposome in environmental field samples analysed by direct-infusion mass spectrometry based metabolomics and lipidomics
    Andrew D. Southam
    Anke Lange
    Raghad Al-Salhi
    Elizabeth M. Hill
    Charles R. Tyler
    Mark R. Viant
    Metabolomics, 2014, 10 : 1050 - 1058
  • [2] A complete workflow for high-resolution spectral-stitching nanoelectrospray direct-infusion mass-spectrometry-based metabolomics and lipidomics
    Southam, Andrew D.
    Weber, Ralf J. M.
    Engel, Jasper
    Jones, Martin R.
    Viant, Mark R.
    NATURE PROTOCOLS, 2017, 12 (02) : 310 - 328
  • [3] A complete workflow for high-resolution spectral-stitching nanoelectrospray direct-infusion mass-spectrometry-based metabolomics and lipidomics
    Andrew D Southam
    Ralf J M Weber
    Jasper Engel
    Martin R Jones
    Mark R Viant
    Nature Protocols, 2017, 12 : 310 - 328
  • [4] A Strategy for Uncovering the Serum Metabolome by Direct-Infusion High-Resolution Mass Spectrometry
    Sun, Xiaoshan
    Jia, Zhen
    Zhang, Yuqing
    Zhao, Xinjie
    Zhao, Chunxia
    Lu, Xin
    Xu, Guowang
    METABOLITES, 2023, 13 (03)
  • [5] Metabolomics-based phenotypic screens for evaluation of drug synergy via direct-infusion mass spectrometry
    Lu, Xiyuan
    Hackman, G. Lavender
    Saha, Achinto
    Rathore, Atul Singh
    Collins, Meghan
    Friedman, Chelsea
    Yi, S. Stephen
    Matsuda, Fumio
    DiGiovanni, John
    Lodi, Alessia
    Tiziani, Stefano
    ISCIENCE, 2022, 25 (05)
  • [6] High-throughput direct-infusion ion trap mass spectrometry: a new method for metabolomics
    Koulman, Albert
    Tapper, Brian A.
    Fraser, Karl
    Cao, Mingshu
    Lane, Geoffrey A.
    Rasmussen, Susanne
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (03) : 421 - 428
  • [7] Diagnosis of lung cancer based on direct-infusion electrospray mass spectrometry of blood plasma metabolites
    Lokhov, Petr G.
    Kharybin, Oleg N.
    Archakov, Alexander I.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2012, 309 : 200 - 205
  • [8] Comparison of liquid chromatography-mass spectrometry and direct infusion microchip electrospray ionization mass spectrometry in global metabolomics of cell samples
    Poho, Paivi
    Lipponen, Katriina
    Bespalov, Maxim M.
    Sikanen, Tiina
    Kotiaho, Tapio
    Kostiainen, Risto
    EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2019, 138
  • [9] Deep Characterization of Serum Metabolome Based on the Segment-Optimized Spectral-Stitching Direct-Infusion Fourier Transform Ion Cyclotron Resonance Mass Spectrometry Approach
    Sun, Xiaoshan
    Xia, Yueyi
    Zhao, Xinjie
    Wang, Xinxin
    Zhang, Yuqing
    Jia, Zhen
    Zheng, Fujian
    Li, Zaifang
    Zhang, Xiuqiong
    Zhao, Chunxia
    Lu, Xin
    Xu, Guowang
    ANALYTICAL CHEMISTRY, 2023, 95 (28) : 10512 - 10521
  • [10] Development of a metabolomic approach based on urine samples and direct infusion mass spectrometry
    Gonzalez-Dominguez, Raill
    Castilla-Quintero, Rocio
    Garcia-Barrera, Tamara
    Luis Gomez-Ariza, Jose
    ANALYTICAL BIOCHEMISTRY, 2014, 465 : 20 - 27