Performance-based fire modelling of intumescent painted steel structures and comparison to EC3

被引:18
作者
Kolsek, J. [1 ]
Cesarek, P. [2 ]
机构
[1] ZAG Slovenian Natl Bldg & Civil Engn Inst, Fire Lab, SI-1000 Ljubljana, Slovenia
[2] Univ Ljubljana, Fac Civil & Geodet Engn, SI-1115 Ljubljana, Slovenia
关键词
Steel; Fire; Intumescent coating; Experiment; Numerical modelling; Eurocode; 3; COMPUTATIONAL FLUID-DYNAMICS; EXPERIMENTAL BEHAVIOR; SHEETING CONNECTION; CONE CALORIMETER; HEAT-TRANSFER; DESIGN; COATINGS; COLUMNS; SUBJECT; AMBIENT;
D O I
10.1016/j.jcsr.2014.10.008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Following the present directives for building products, the manufacturers of intumescent paints for fire protection of structural steel typically offer tables for presentation of the product's insulating efficiency showing its dry film thicknesses (DFTs) required to sufficiently delay the defined steel critical temperature. From these tables only the final time of reaching this critical limit is obtained clearly, but the overall time evolution of steel temperature remains unknown. In connection to EC3, these data are only sufficient for the use of a simplified design procedure, mostly the method of critical temperature (MCT). Although of a questionable adequacy for cases of restrained thermal dilatations this method is, thus, often applied regardless of the specifics of the structural assembly. The severity of the error implemented by such a simplification is taken as the principal focus of the paper. In providing an answer, fire test results are presented for 13 different steel members protected by different DFTs of a selected intumescent coating. Then, the time-dependent thermal conductivity of the coating is derived and numerical procedure is composed for obtaining the real fire response of intumescent painted assemblies. The method is implemented into a parametric study. The calculated critical times are compared against the critical times suggested by the MCT revealing the MCT being severely on the unsafe side for some cases. The paper thereby confirms the initial hypothesis that the present way of presenting the fire-protective intumescent paints for structural steel is insufficient and will need to be upgraded in the future. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:91 / 103
页数:13
相关论文
共 42 条
[1]   Tensile Membrane Action of Thin Slabs Exposed to Thermal Gradients [J].
Abu, Anthony K. ;
Burgess, Ian W. ;
Plank, Roger J. .
JOURNAL OF ENGINEERING MECHANICS, 2013, 139 (11) :1497-1507
[2]  
[Anonymous], 2013, 1338182013 EN
[3]  
[Anonymous], 2004, EUR 3 DES STEEL 1 2
[4]  
[Anonymous], 2008, 318 ACI COMM
[5]  
[Anonymous], 2012, ABAQUS VERS 6 12 DOC
[6]  
[Anonymous], 2004, EUR 2 DES CONCR 1 2
[7]  
[Anonymous], 2012, 136312012 EN
[8]   A Study on the Conservativeness of ISO Standard Fire in Office Buildings [J].
Bahr, Oliver .
JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2014, 5 (01) :35-46
[9]   Assessing the performance of intumescent coatings using bench-scaled cone calorimeter and finite difference simulations [J].
Bartholmai, M. ;
Schartel, B. .
FIRE AND MATERIALS, 2007, 31 (03) :187-205
[10]  
Beitel J., 2002, 02843 NIST GCR