Enantiomer separation of N-protected amino acids by non-aqueous capillary electrophoresis and high-performance liquid chromatography with tert.-butyl carbamoylated quinine in either the background electrolyte or the stationary phase

被引:32
作者
Piette, V
Lämmerhofer, M
Lindner, W
Crommen, J
机构
[1] Sci Inst Publ Hlth Louis Pasteur, Lab Drug Anal, B-1050 Brussels, Belgium
[2] Univ Vienna, Inst Analyt Chem, A-1090 Vienna, Austria
[3] Univ Liege, Inst Pharm, Dept Pharmaceut Analyt Chem, B-4000 Liege 1, Belgium
关键词
enantiomer separation; background electrolyte composition; non-aqueous capillary electrophoresis; chiral stationary phases; LC; chiral selectors; amino acids; tert.-butylcarbamoylquinine; alkaloids; cinchona alkaloids;
D O I
10.1016/S0021-9673(02)01465-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A non-aqueous CE method was developed for evaluating the chiral discrimination potential of cinchona alkaloids and different kinds of carbamoylated derivatives of quinine and quinidine type chiral selectors towards acidic analytes, in particular a series of various Bz (benzoyl), DNB (3,5-dinitrobenzoyl) and DNZ (3,5-dinitrobenzyloxycarbonyl) amino acid derivatives. In this study, the enantioselectivity values obtained in non-aqueous CE with tert-butyl carbamoylated quinine as chiral additive have been compared with the values found for the same series of selectands in HPLC using the same selector immobilized onto silica as chiral stationary phase. Similarly to the background electrolyte used in CE an ethanol-methanol mixture (60:40, v/v) containing 100 mM octanoic acid and 12.5 mM ammonia has been selected as HPLC mobile phase. Under these conditions, a good correlation (r=0.954) between the enantioselectivities observed with the two techniques has been obtained. Thus the non-aqueous CE method can be applied as a screening tool for the rapid evaluation of the chiral discrimination potential of a large set of newly developed chiral selectors derived from quinine and related alkaloids. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:421 / 427
页数:7
相关论文
共 36 条
[1]  
*COUNC EUR, 1996, EUR PHARM
[2]   Evaluation of the contribution to enantioselectivity of quinine and quinidine scaffolds in chemically and physically mixed chiral selectors [J].
Franco, P ;
Klaus, PM ;
Minguillón, C ;
Lindner, W .
CHIRALITY, 2001, 13 (04) :177-186
[3]   Novel cinchona alkaloid carbamate C9-dimers as chiral anion-exchange type selectors for high-performance liquid chromatography [J].
Franco, P ;
Lämmerhofer, M ;
Klaus, PM ;
Lindner, W .
JOURNAL OF CHROMATOGRAPHY A, 2000, 869 (1-2) :111-127
[4]  
*ISO, 1994, 57252 ISO INT ORG ST
[5]  
Kleidernigg OP, 1996, ENANTIOMER, V1, P387
[6]  
Lammerhofer M, 1998, AM LAB, V30, P71
[7]  
Lämmerhofer M, 2001, J SEP SCI, V24, P706, DOI 10.1002/1615-9314(20010901)24:9&lt
[8]  
706::AID-JSSC706&gt
[9]  
3.0.CO
[10]  
2-