Effect of corrosion on flexural strength of reinforced concrete beams with polypropylene fibers

被引:56
作者
Bicer, Kamil [1 ]
Yalciner, Hakan [2 ]
Balks, Ayse Pekrioglu [1 ]
Kumbasaroglu, Atila [2 ]
机构
[1] Cyprus Int Univ, Dept Civil Engn, Mersin 10, Lefkosa, North Cyprus, Turkey
[2] Erzincan Univ, Dept Civil Engn, Erzincan, Turkey
关键词
Flexural strength; Corrosion; Beams; Polypropylene fibers; Bond-slip; CORRODED RC BEAMS; SYNTHETIC-FIBERS; BOND BEHAVIOR; STEEL; SHEAR; PERFORMANCE; PREDICTION; SYSTEMS;
D O I
10.1016/j.conbuildmat.2018.07.021
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An experimental study was performed to investigate the effects of polypropylene fibers on uncorroded and corroded reinforced concrete beams. Three different volume fractions of polypropylene fibers having 0, 0.5, and 1.5%, were tested at four corrosion levels of 0% and approximately 5, 7, and 9%. A full scale of an accelerated corrosion pool was used for the accelerated corrosion process. Reinforced concrete beams were used for an under monotonic bending test. The contribution of the actual corrosion levels of transverse and longitudinal reinforcement bars to the total corrosion levels were obtained from reinforcement bars fully extracted from concrete. Flexural strength, bond-slip, and moment-curvature relationships were examined for uncorroded and corroded reinforced concrete beams. A new model was developed to predict the flexural strength of corroded reinforced concrete beams. The proposed model for predicting the residual flexural strength of corroded beams was compared with test data published in previous studies. Furthermore, a novel model is presented for improved predictions between the actual and theoretically estimated corrosion mass losses, based on Faraday's law, with the aid of fully extracted reinforcement bars. The model used to predict the flexural strength of corroded reinforced concrete beams with large sizes demonstrated good agreement with current and previously published literature data. In the case of corroded beams comprising differing amounts of polypropylene fibers, the performance of the corroded beams was limited by a fiber volume fraction of 1.5% at low corrosion levels. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:574 / 588
页数:15
相关论文
共 38 条
[2]  
Ahmad S, 2009, ARAB J SCI ENG, V34, P95
[3]  
[Anonymous], 1991, Reinforced concrete structures
[4]  
ASTM, 2003, ANN BOOK ASTM STAND
[5]  
Auyeung Y, 2000, ACI MATER J, V97, P214
[6]   Flexural strength of corroded reinforced concrete beams [J].
Azad, A. K. ;
Ahmad, S. ;
Al-Gohi, B. H. A. .
MAGAZINE OF CONCRETE RESEARCH, 2010, 62 (06) :405-414
[7]  
Azad AK, 2007, ACI MATER J, V104, P40
[8]  
BAZANT ZP, 1979, J STRUCT DIV-ASCE, V105, P1137
[9]   Engineering failure analysis of corroded RC beams in flexure and shear [J].
Campione, G. ;
Cannella, F. .
ENGINEERING FAILURE ANALYSIS, 2018, 86 :100-114
[10]   Shear and flexural strength prediction of corroded RC beams [J].
Campione, G. ;
Cannella, F. ;
Cavaleri, L. .
CONSTRUCTION AND BUILDING MATERIALS, 2017, 149 :395-405