Comparison of the accuracy of two different dynamic navigation system registration methods for dental implant placement: A retrospective study

被引:35
作者
Ma, Feifei
Sun, Feng [1 ]
Wei, Tai
Ma, Yu
机构
[1] Peking Univ, Clin Div 1, Sch & Hosp Stomatol, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
关键词
accuracy; computer-assisted; dynamic navigation system; retrospective; SURFACE REGISTRATION; PATIENT REGISTRATION; SURGERY; RECONSTRUCTION; TECHNOLOGY;
D O I
10.1111/cid.13090
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background Dynamic navigation approaches are widely employed in the context of implant placement surgery, with registration being integral to the accuracy of such navigation. Relatively few studies to date, however, have compared different registration approaches, and such a comparison has the potential to guide the development of more accurate and reliable clinical registration methodology. Purpose This study was developed to compare the accuracy of dynamic navigation-based dental implant placement conducted using either U-tube or cusp registration methods. Materials and Methods Medical records from all patients that had undergone implant surgery between August 2019 and October 2020 in the First Clinical Division of the Peking University Hospital of Stomatology were retrospectively reviewed, with 64 patients and 99 implants ultimately meeting with study inclusion criteria. Implant placement accuracy was gauged via the superimposition of the planned implant position in preoperative cone-beam computed tomography (CBCT) images with the true postoperative implant position in postoperative CBCT images. Accuracy was measured based upon the angular deviation, entry deviation (3-dimensional [3D] deviation in the coronal aspect of the alveolar ridge), and apex deviation (3D deviation in the apical area of the implant) when comparing these two positions. Results The angular deviation, entry deviation, and apex deviation of all analyzed implants were 3.29 +/- 0.17 degrees, 1.29 +/- 0.07 mm, and 1.43 +/- 0.08 mm, respectively, while in the cusp registration group these respective values were 3.25 +/- 1.58 degrees, 1.28 +/- 0.60 mm, and 1.34 +/- 0.63 mm as compared to 3.35 +/- 1.78 degrees, 1.30 +/- 0.78 mm, 1.55 +/- 0.9 mm in the U-tube group, respectively. No significant differences in accuracy were observed when comparing these two registration techniques. Conclusion Dynamic computer-assisted surgical systems can facilitate accurate implantation, and both the U-tube and cusp registration methods exhibit similar levels of accuracy. As the cusp registration technique can overcome some of the limitations of the U-tube strategy without the need for an additional registration device, it may be more convenient for clinical use and warrants further research.
引用
收藏
页码:352 / 360
页数:9
相关论文
共 48 条
[1]  
Alp MS, 1998, NEUROL RES, V20, P31
[2]   COMPUTER-ASSISTED 3-DIMENSIONAL PLANNING IN CRANIOFACIAL SURGERY [J].
ALTOBELLI, DE ;
KIKINIS, R ;
MULLIKEN, JB ;
CLINE, H ;
LORENSEN, W ;
JOLESZ, F .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1993, 92 (04) :576-585
[3]   Accuracy of dental implant placement via dynamic navigation or the freehand method: A split-mouth randomized controlled clinical trial [J].
Aydemir, Ceyda Aktolun ;
Arisan, Volkan .
CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (03) :255-263
[4]   Factors influencing transfer accuracy of cone beam CT-derived template-based implant placement [J].
Behneke, Alexandra ;
Burwinkel, Matthias ;
Behneke, Nikolaus .
CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (04) :416-423
[5]   Implant Placement Accuracy Using Dynamic Navigation [J].
Block, Michael S. ;
Emery, Robert W. ;
Lank, Kathryn ;
Ryan, James .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (01) :92-99
[6]   Static or Dynamic Navigation for Implant Placement-Choosing the Method of Guidance [J].
Block, Michael S. ;
Emery, Robert W. .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 74 (02) :269-277
[7]   Accuracy of image-guided implantology [J].
Brief, J ;
Edinger, D ;
Hassfeld, S ;
Eggers, G .
CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (04) :495-501
[8]  
Buser D, 2004, INT J ORAL MAX IMPL, V19, P43
[9]   10-Year Survival and Success Rates of 511 Titanium Implants with a Sandblasted and Acid-Etched Surface: A Retrospective Study in 303 Partially Edentulous Patients [J].
Buser, Daniel ;
Janner, Simone F. M. ;
Wittneben, Julia-Gabriela ;
Braegger, Urs ;
Ramseier, Christoph A. ;
Salvi, Giovanni E. .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (06) :839-851
[10]   Exploring training dental implant placement using computer-guided implant navigation system for predoctoral students: A pilot study [J].
Deeb, Janina Golob ;
Bencharit, Sompop ;
Carrico, Caroline K. ;
Lukic, Marija ;
Hawkins, Daniel ;
Rener-Sitar, Ksenija ;
Deeb, George R. .
EUROPEAN JOURNAL OF DENTAL EDUCATION, 2019, 23 (04) :415-423