Oxygen and oxidative stress in the perinatal period

被引:187
作者
Torres-Cuevas, Isabel [1 ]
Parra-Llorca, Anna [1 ]
Sanchez-Illana, Angel [1 ]
Nunez-Ramiro, Antonio [1 ,2 ]
Kuligowski, Julia [1 ]
Chafer-Pericas, Consuelo [1 ]
Cernada, Maria [1 ,2 ]
Escobar, Justo [3 ]
Vento, Maximo [1 ,2 ]
机构
[1] Inst Invest Sanitaria La Fe, Grp Invest Perinatol, Valencia, Spain
[2] Hosp Univ & Politecn La Fe, Serv Neonatol, Valencia, Spain
[3] Sabartech SL, Biopolo Inst Invest Sanitaria La Fe, Sci Dept, Valencia, Spain
来源
REDOX BIOLOGY | 2017年 / 12卷
关键词
Oxygen; Oxidative stress; Ischemia-reperfusion; High-risk pregnancy; Newborn; Biomarkers; CARDIOVASCULAR CARE SCIENCE; HYPOXIC NEWBORN PIGLETS; DOSE-DEPENDENT INCREASE; LIPID-PEROXIDATION; PRETERM INFANTS; SUPPLEMENTARY OXYGEN; 100-PERCENT OXYGEN; ROOM-AIR; CARDIOPULMONARY-RESUSCITATION; INTERNATIONAL CONSENSUS;
D O I
10.1016/j.redox.2017.03.011
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Fetal life evolves in a hypoxic environment. Changes in the oxygen content in utero caused by conditions such as pre-eclampsia or type I diabetes or by oxygen supplementation to the mother lead to increased free radical production and correlate with perinatal outcomes. In the fetal-to-neonatal transition asphyxia is characterized by intermittent periods of hypoxia ischemia that may evolve to hypoxic ischemic encephalopathy associated with neurocognitive, motor, and neurosensorial impairment. Free radicals generated upon reoxygenation may notably increase brain damage. Hence, clinical trials have shown that the use of 100% oxygen given with positive pressure in the airways of the newborn infant during resuscitation causes more oxidative stress than using air, and increases mortality. Preterm infants are endowed with an immature lung and antioxidant system. Clinical stabilization of preterm infants after birth frequently requires positive pressure ventilation with a gas admixture that contains oxygen to achieve a normal heart rate and arterial oxygen saturation. In randomized controlled trials the use high oxygen concentrations (90% to 100%) has caused more oxidative stress and clinical complications that the use of lower oxygen concentrations (30-60%). A correlation between the amount of oxygen received during resuscitation and the level of biomarkers of oxidative stress and clinical outcomes was established. Thus, based on clinical outcomes and analytical results of oxidative stress biomarkers relevant changes were introduced in the resuscitation policies. However, it should be underscored that analysis of oxidative stress biomarkers in biofluids has only been used in experimental and clinical research but not in clinical routine. The complexity of the technical procedures, lack of automation, and cost of these determinations have hindered the routine use of biomarkers in the clinical setting. Overcoming these technical and economical difficulties constitutes a challenge for the immediate future since accurate evaluation of oxidative stress would contribute to improve the quality of care of our neonatal patients.
引用
收藏
页码:674 / 681
页数:8
相关论文
共 84 条
[1]  
AASEN AO, 1979, CIRC SHOCK, V6, P277
[2]  
Aguar M., 2014, EPAS, V3843, P540
[3]  
[Anonymous], 2015, BBA-MOL CELL BIOL L, DOI DOI 10.1016/j.bbalip.2014.10.007
[4]  
Biomarker Definitions Working Group, 2001, CLIN PHARMACOL THER, V69
[5]   Oxidative stress [J].
Burton, Graham J. ;
Jauniaux, Eric .
BEST PRACTICE & RESEARCH CLINICAL OBSTETRICS & GYNAECOLOGY, 2011, 25 (03) :287-299
[6]   Oxygen, the Janus gas; its effects on human placental development and function [J].
Burton, Graham J. .
JOURNAL OF ANATOMY, 2009, 215 (01) :27-35
[7]   Elevated protein carbonyls and lipid peroxidation products correlating with myeloperoxidase in tracheal aspirates from premature infants [J].
Buss, IH ;
Darlow, BA ;
Winterbourn, CC .
PEDIATRIC RESEARCH, 2000, 47 (05) :640-645
[8]   Ventilator-Associated Pneumonia in Neonatal Patients: An Update [J].
Cernada, Maria ;
Brugada, Maria ;
Golombek, Sergio ;
Vento, Maximo .
NEONATOLOGY, 2014, 105 (02) :98-107
[9]   Preliminary case control study to establish the correlation between novel peroxidation biomarkers in cord serum and the severity of hypoxic ischemic encephalopathy [J].
Chafer-Pericas, Consuelo ;
Cernada, Maria ;
Rahkonen, Leena ;
Stefanovic, Vedran ;
Andersson, Sture ;
Vento, Maximo .
FREE RADICAL BIOLOGY AND MEDICINE, 2016, 97 :244-249
[10]   Supplemental oxygen for caesarean section during regional anaesthesia [J].
Chatmongkolchart, Sunisa ;
Prathep, Sumidtra .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2016, (03)