Do patients with the centrifugal flow HeartMate 3 or HeartWare left ventricular assist device have better outcomes compared to those with axial flow HeartMate II?

被引:11
作者
Florisson, Daniel S. [1 ]
Conte, Sean M. [2 ]
De Bono, Joshua A. [1 ]
Newcomb, Andrew E. [1 ]
机构
[1] St Vincents Hosp Melbourne, Dept Cardiothorac Surg, 41 Victoria Parade, Fitzroy, Vic 3053, Australia
[2] St Vincents Hosp Sydney, Dept Med, Darlinghurst, NSW, Australia
关键词
Left ventricular assist device; Axial; Centrifugal; Outcomes; HeartWare left ventricular assist device; HeartWare; HeartMate3; HeartMate II; MOMENTUM; 3; ENDURANCE; SUPPORT; STROKE; EVENTS; TRIAL; RISK; PUMP;
D O I
10.1093/icvts/ivz202
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A best evidence topic was written according to a structured protocol. The question addressed was 'Do patients with centrifugal flow HeartMate 3 (HM3) or HeartWare left ventricular assist device (HVAD) have better outcomes compared to those with the axial flow HeartMate II (HMII)?' Altogether 1791 papers were found using the reported search, of which 21 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. In publications reporting on MOMENTUM 3 randomized control trial (RCT), HM3 had better outcomes compared to HMII with a lower rate of pump thrombosis (1.1% vs 15.7%), stroke events (10.1% vs 19.2%) and ischaemic stroke (6.3% vs 13.4%) at 2-year follow-up. Markers of quality of life and functional capacity were comparable between the 2 devices at 6months. In publications reporting on ENDURANCE RCTs, compared to HMII, patients with HVAD had poorer outcomes with an increased rate of sepsis (23.6% vs 15.4%), stroke (29.7% vs 12.1%) and right heart failure (38.5% vs 26.8%) postoperatively. Outcomes were improved for the HVAD group in a more recent RCT where strict blood pressure control was instigated postoperatively. Outcomes from retrospective studies comparing HMII with HVAD varied, with some publications reporting higher rates of right ventricular assist device use (29% vs 15%), gastrointestinal bleeding (30% vs 0%), cerebrovascular accident (44% vs 10%), transient ischaemic attack (5% vs 2%) and higher cumulative risk of infection and haemorrhagic cerebrovascular accident with HVAD. This is not consistent across these studies, and 9 studies including a systematic review reported no difference in any outcomes. In conclusion, patients with centrifugal flow HM3 have better outcomes than those with axial flow HMII. Although there is some variability in outcomes in retrospective studies, patients with centrifugal flow HeartWare HVAD have similar outcomes to those with axial flow HMII when strict blood pressure control is instigated postoperatively. By inference, centrifugal flow HM3 would appear to be the superior device, although all conclusions are based on 1 large (industry-sponsored) RCT.
引用
收藏
页码:844 / 851
页数:8
相关论文
共 22 条
[1]   Acute kidney injury after implantation of a left ventricular assist device: a comparison of axial-flow (HeartMate II) and centrifugal-flow (HeartWare HVAD) devices [J].
Anjum, Azeen ;
Kurihara, Chitaru ;
Critsinelis, Andre ;
Kawabori, Masashi ;
Sugiura, Tadahisa ;
Civitello, Andrew B. ;
Etheridge, Whitson B. ;
Delgado, Reynolds M. ;
Simpson, Leo ;
George, Joggy K. ;
Nair, Ajith P. ;
Frazier, O. H. ;
Morgan, Jeffrey A. .
JOURNAL OF ARTIFICIAL ORGANS, 2018, 21 (03) :285-292
[2]   Ambient hemolysis and activation of coagulation is different between Heart Mate II and Heart Ware left ventricular assist devices [J].
Birschmann, Ingvild ;
Dittrich, Marcus ;
Eller, Thomas ;
Wiegmann, Bettina ;
Reininger, Armin J. ;
Budde, Ulrich ;
Strueber, Martin .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (01) :80-87
[3]   Stroke and Intracranial Hemorrhage in HeartMate II and HeartWare Left Ventricular Assist Devices: A Systematic Review [J].
Cho, Sung M. ;
Moazami, Nader ;
Frontera, Jennifer A. .
NEUROCRITICAL CARE, 2017, 27 (01) :17-25
[4]   Adverse neurologic events in patients bridged with Long-term mechanical circulatory support: A device-specific comparative analysis [J].
Coffin, Samuel. T. ;
Haglund, Nicholas A. ;
Davis, Mary E. ;
Xu, Meng ;
Dunlay, Shannon M. ;
Cowger, Jennifer A. ;
Shah, Palak ;
Aaronson, Keith D. ;
Pagani, Frank D. ;
Stulak, John M. ;
Maltais, Simon .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (12) :1578-1585
[5]   Comprehensive Analysis of Stroke in the Long-Term Cohort of the MOMENTUM 3 Study: A Randomized Controlled Trial of the HeartMate 3 Versus the HeartMate II Cardiac Pump [J].
Colombo, Paolo C. ;
Mehra, Mandeep R. ;
Goldstein, Daniel J. ;
Estep, Jerry D. ;
Salerno, Christopher ;
Jorde, Ulrich P. ;
Cowger, Jennifer A. ;
Cleveland, Joseph C. ;
Uriel, Nir ;
Sayer, Gabriel ;
Skipper, Eric R. ;
Downey, Francis X. ;
Ono, Masahiro ;
Hooker, Robert ;
Anyanwu, Anelechi C. ;
Givertz, Michael M. ;
Mahr, Claudius ;
Topuria, Ia ;
Somo, Sami I. ;
Crandall, Daniel L. ;
Horstmanshof, Douglas A. .
CIRCULATION, 2019, 139 (02) :155-168
[6]   Quality of life and functional capacity outcomes in the MOMENTUM 3 trial at 6 months: A call for new metrics for left ventricular assist device patients [J].
Cowger, Jennifer A. ;
Naka, Yoshifumi ;
Aaronson, Keith D. ;
Horstmanshof, Douglas ;
Gulati, Sanjeev ;
Rinde-Hoffman, Debbie ;
Pinney, Sean ;
Adatya, Sirtaz ;
Farrar, David J. ;
Jorde, Ulrich P. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (01) :15-24
[7]  
Dunning Joel, 2003, Interact Cardiovasc Thorac Surg, V2, P405, DOI 10.1016/S1569-9293(03)00191-9
[8]   Risk factors, mortality, and timing of ischemic and hemorrhagic stroke with left ventricular assist devices [J].
Frontera, Jennifer A. ;
Starling, Randall ;
Cho, Sung-Min ;
Nowacki, Amy S. ;
Uchino, Ken ;
Hussain, M. Shazam ;
Mountis, Maria ;
Moazami, Nader .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (06) :673-683
[9]   Is there a difference in bleeding after left ventricular assist device implant: centrifugal versus axial? [J].
Gaffey, Ann C. ;
Chen, Carol W. ;
Chung, Jennifer J. ;
Han, Jason ;
Bermudez, Christian A. ;
Wald, Joyce ;
Atluri, Pavan .
JOURNAL OF CARDIOTHORACIC SURGERY, 2018, 13
[10]   Fatal Neurologic Dysfunction During Continuous-Flow Left Ventricular Assist Device Support [J].
Kawabori, Masashi ;
Conyer, Ryan T. ;
Kurihara, Chitaru ;
Sugiura, Tadahisa ;
Civitello, Andrew B. ;
Frazier, O. H. ;
Morgan, Jeffrey A. .
ANNALS OF THORACIC SURGERY, 2019, 107 (04) :1132-1138