Simulated Low-Dose Computed Tomography in Oncological Patients: A Feasibility Study

被引:7
|
作者
Yamamura, Jin [1 ]
Tornquist, Katharina [1 ]
Buchert, Ralph [1 ]
Wildberger, Joachim [2 ]
Nagel, H. D. [3 ]
Dichtl, Daniela [1 ]
Adam, Gerhard [1 ]
Wedegaertner, Ulrike [1 ]
机构
[1] Univ Hosp Hamburg Eppendorf, Dept Diagnost & Intervent Radiol, Hamburg, Germany
[2] Univ Hosp Aachen, Dept Diagnost & Intervent Radiol, Aachen, Germany
[3] Philips Med Syst, Aachen, Germany
关键词
oncology; dose reduction; computed tomography; EARLY LUNG-CANCER; IMAGE QUALITY; HELICAL CT; MULTISLICE CT; SPIRAL CT; BOMB SURVIVORS; PEDIATRIC CT; RADIATION; REDUCTION; RISK;
D O I
10.1097/RCT.0b013e3181c95b67
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Image quality of chest and abdominal computed tomographic (CT) scans was evaluated at different doses to assess the lowest value of x-ray dose at which the image quality was not being affected. Materials and Methods: Using multislice CT (MSCT), 29 patients who submitted to follow-up examinations were examined using a combined MSCT protocol of the chest and the abdomen on 4-raw MSCT (Siemens, Erlangen, Germany). For each examination, approximately 120 mL of contrast agent (Bracco-Altana, Konstanz, Germany) was applied intravenously. The raw data were transferred to an external personal computer equipped with an image reconstruction software (CardioRecon 6; Siemens, Forchheim, Germany) to simulate 5 different dose levels. To simulate them correctly, a milliampere second-dependent noise was added to every image, so that the changes in a current- time product could be imitated. The images were compared in consensus by 2 radiologists who were not informed about the technical scanning parameters, that is, dose parameters, and were graded in 4 different subcategories on a 1-to-5-point scale. For statistical analysis, the Friedman test was used. Additional evaluations for lesions smaller than 1.0 cm were performed and analyzed separately. Results: For image noise, there was a significant change between 40 and 60 mA s. For lesion detection, there was no significant change. The contour of the small objects did not differ between 90, 60, and 40 mA s. However, a dose reduction to 30 mA s had a significant effect. The contrast did not differ between 90, 60, 40, and even down to 30 mA s. Only a maximal dose reduction to 20 mA s had a significant effect on the contrast. The level of noise was most sensitive to the current. Whereas a dose reduction to 60 mA s did not yet have a significant effect, there was a significant increase of noise at 40 mA s. Conclusions: The MSCT can be applied with a lower dose than that usually selected in examinations at present to follow-up and stage the oncological patients adequately.
引用
收藏
页码:302 / 308
页数:7
相关论文
共 50 条
  • [21] The Accuracy of Low-dose Computed Tomography Protocol in Patients With Suspected Acute Appendicitis The OPTICAP Study
    Sippola, Suvi
    Virtanen, Johanna
    Tammilehto, Ville
    Gronroos, Juha
    Hurme, Saija
    Niiniviita, Hannele
    Lietzen, Elina
    Salminen, Paulina
    ANNALS OF SURGERY, 2020, 271 (02) : 332 - 338
  • [22] AI Denoising Significantly Improves Image Quality in Whole-Body Low-Dose Computed Tomography Staging
    Brendlin, Andreas S.
    Plajer, David
    Chaika, Maryanna
    Wrazidlo, Robin
    Estler, Arne
    Tsiflikas, Ilias
    Artzner, Christoph P.
    Afat, Saif
    Bongers, Malte N.
    DIAGNOSTICS, 2022, 12 (01)
  • [23] Feasibility of a patient decision aid about lung cancer screening with low-dose computed tomography
    Volk, Robert J.
    Linder, Suzanne K.
    Leal, Viola B.
    Rabius, Vance
    Cinciripini, Paul M.
    Kamath, Geetanjali R.
    Munden, Reginald F.
    Bevers, Therese B.
    PREVENTIVE MEDICINE, 2014, 62 : 60 - 63
  • [24] Parallel processing model for low-dose computed tomography image denoising
    Yao, Libing
    Wang, Jiping
    Wu, Zhongyi
    Du, Qiang
    Yang, Xiaodong
    Li, Ming
    Zheng, Jian
    VISUAL COMPUTING FOR INDUSTRY BIOMEDICINE AND ART, 2024, 7 (01)
  • [25] Understanding the harm of low-dose computed tomography radiation to the body (Review)
    Shi, Hai-Min
    Sun, Zhi-Chao
    Ju, Fang-He
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2022, 24 (02)
  • [26] Establishment of diagnostic reference levels in low-dose renal computed tomography
    Rawashdeh, Mohammad
    Saade, Charbel
    ACTA RADIOLOGICA, 2023, 64 (02) : 829 - 836
  • [27] Screening for lung cancer with low-dose computed tomography
    Diederich, S
    Wormanns, D
    Heindel, W
    RADIOLOGE, 2001, 41 (03): : 256 - 260
  • [28] VARIATIONAL DEEP LEARNING FOR LOW-DOSE COMPUTED TOMOGRAPHY
    Kobler, Erich
    Muckley, Matthew
    Chen, Baiyu
    Knoll, Florian
    Hammernik, Kerstin
    Pock, Thomas
    Sodickson, Daniel
    Otazo, Ricardo
    2018 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2018, : 6687 - 6691
  • [29] Low-Dose Cardiovascular Computed Tomography: Where are the Limits?
    Paul Schoenhagen
    Carla M. Thompson
    Sandra S. Halliburton
    Current Cardiology Reports, 2012, 14 : 17 - 23
  • [30] A sinogram denoising algorithm for low-dose computed tomography
    Davood Karimi
    Pierre Deman
    Rabab Ward
    Nancy Ford
    BMC Medical Imaging, 16