Simulated Low-Dose Computed Tomography in Oncological Patients: A Feasibility Study

被引:7
|
作者
Yamamura, Jin [1 ]
Tornquist, Katharina [1 ]
Buchert, Ralph [1 ]
Wildberger, Joachim [2 ]
Nagel, H. D. [3 ]
Dichtl, Daniela [1 ]
Adam, Gerhard [1 ]
Wedegaertner, Ulrike [1 ]
机构
[1] Univ Hosp Hamburg Eppendorf, Dept Diagnost & Intervent Radiol, Hamburg, Germany
[2] Univ Hosp Aachen, Dept Diagnost & Intervent Radiol, Aachen, Germany
[3] Philips Med Syst, Aachen, Germany
关键词
oncology; dose reduction; computed tomography; EARLY LUNG-CANCER; IMAGE QUALITY; HELICAL CT; MULTISLICE CT; SPIRAL CT; BOMB SURVIVORS; PEDIATRIC CT; RADIATION; REDUCTION; RISK;
D O I
10.1097/RCT.0b013e3181c95b67
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Image quality of chest and abdominal computed tomographic (CT) scans was evaluated at different doses to assess the lowest value of x-ray dose at which the image quality was not being affected. Materials and Methods: Using multislice CT (MSCT), 29 patients who submitted to follow-up examinations were examined using a combined MSCT protocol of the chest and the abdomen on 4-raw MSCT (Siemens, Erlangen, Germany). For each examination, approximately 120 mL of contrast agent (Bracco-Altana, Konstanz, Germany) was applied intravenously. The raw data were transferred to an external personal computer equipped with an image reconstruction software (CardioRecon 6; Siemens, Forchheim, Germany) to simulate 5 different dose levels. To simulate them correctly, a milliampere second-dependent noise was added to every image, so that the changes in a current- time product could be imitated. The images were compared in consensus by 2 radiologists who were not informed about the technical scanning parameters, that is, dose parameters, and were graded in 4 different subcategories on a 1-to-5-point scale. For statistical analysis, the Friedman test was used. Additional evaluations for lesions smaller than 1.0 cm were performed and analyzed separately. Results: For image noise, there was a significant change between 40 and 60 mA s. For lesion detection, there was no significant change. The contour of the small objects did not differ between 90, 60, and 40 mA s. However, a dose reduction to 30 mA s had a significant effect. The contrast did not differ between 90, 60, 40, and even down to 30 mA s. Only a maximal dose reduction to 20 mA s had a significant effect on the contrast. The level of noise was most sensitive to the current. Whereas a dose reduction to 60 mA s did not yet have a significant effect, there was a significant increase of noise at 40 mA s. Conclusions: The MSCT can be applied with a lower dose than that usually selected in examinations at present to follow-up and stage the oncological patients adequately.
引用
收藏
页码:302 / 308
页数:7
相关论文
共 50 条
  • [11] Feasibility study on many-view under-sampling technique for low-dose computed tomography
    Cho, Seungryong
    Lee, Taewon
    Min, Jonghwan
    Chung, Hyekyun
    OPTICAL ENGINEERING, 2012, 51 (08)
  • [12] An Investigation of the Feasibility and Utility of a Low-dose Cone-beam Computed Tomography Scan Protocol for Head and Neck Cancer Patients
    Turner, Angela
    McGuffin, Merrylee
    Au, Philip
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2015, 46 (02) : 141 - 147
  • [13] Low-Dose Unenhanced Computed Tomography with Iterative Reconstruction for Diagnosis of Ureter Stones
    Chi, Byung Hoon
    Chang, In Ho
    Lee, Dong Hoon
    Park, Sung Bin
    Kim, Kyung Do
    Moon, Young Tae
    Hur, Taekyu
    YONSEI MEDICAL JOURNAL, 2018, 59 (03) : 389 - 396
  • [14] Low-Dose Computed Tomography in the Evaluation of Urolithiasis
    Bhatt, Kavita
    Monga, Manoj
    Remer, Erick M.
    JOURNAL OF ENDOUROLOGY, 2015, 29 (05) : 504 - 511
  • [15] Dosimetry for low-dose computed tomography of the chest
    Lenzen, H
    Roos, N
    Diederich, S
    Meier, N
    RADIOLOGE, 1996, 36 (06): : 483 - 488
  • [16] Adaptive noise reduction toward low-dose computed tomography
    Lu, HB
    Li, X
    Li, LH
    Chen, DQ
    Xing, YX
    Hsieh, J
    Liang, ZR
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 759 - 766
  • [17] Dose Optimization for Computed Tomography Localizer Radiographs for Low-Dose Lung Computed Tomography Examinations
    Schmidt, Bernhard T.
    Hupfer, Martin
    Saltybaeva, Natalia
    Kolditz, Daniel
    Kalender, Willi A.
    INVESTIGATIVE RADIOLOGY, 2017, 52 (02) : 81 - 86
  • [18] Impact of Low-Dose Computed Tomography on Computed Tomography Orders and Scan Length
    Simmons, Curtis
    Milburn, James
    OCHSNER JOURNAL, 2019, 19 (04): : 303 - 308
  • [19] Low-dose computed tomography with 4th-generation iterative reconstruction algorithm in assessment of oncologic patients
    Ippolito, Davide
    Casiraghi, Alessandra Silvia
    Franzesi, Cammillo Talei
    Fior, Davide
    Meloni, Franca
    Sironi, Sandro
    WORLD JOURNAL OF GASTROINTESTINAL ONCOLOGY, 2017, 9 (10) : 423 - 430
  • [20] Development and validation of a low dose simulator for computed tomography
    Joemai, R. M. S.
    Geleijns, J.
    Veldkamp, W. J. H.
    EUROPEAN RADIOLOGY, 2010, 20 (04) : 958 - 966