Simulated Low-Dose Computed Tomography in Oncological Patients: A Feasibility Study

被引:7
|
作者
Yamamura, Jin [1 ]
Tornquist, Katharina [1 ]
Buchert, Ralph [1 ]
Wildberger, Joachim [2 ]
Nagel, H. D. [3 ]
Dichtl, Daniela [1 ]
Adam, Gerhard [1 ]
Wedegaertner, Ulrike [1 ]
机构
[1] Univ Hosp Hamburg Eppendorf, Dept Diagnost & Intervent Radiol, Hamburg, Germany
[2] Univ Hosp Aachen, Dept Diagnost & Intervent Radiol, Aachen, Germany
[3] Philips Med Syst, Aachen, Germany
关键词
oncology; dose reduction; computed tomography; EARLY LUNG-CANCER; IMAGE QUALITY; HELICAL CT; MULTISLICE CT; SPIRAL CT; BOMB SURVIVORS; PEDIATRIC CT; RADIATION; REDUCTION; RISK;
D O I
10.1097/RCT.0b013e3181c95b67
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Image quality of chest and abdominal computed tomographic (CT) scans was evaluated at different doses to assess the lowest value of x-ray dose at which the image quality was not being affected. Materials and Methods: Using multislice CT (MSCT), 29 patients who submitted to follow-up examinations were examined using a combined MSCT protocol of the chest and the abdomen on 4-raw MSCT (Siemens, Erlangen, Germany). For each examination, approximately 120 mL of contrast agent (Bracco-Altana, Konstanz, Germany) was applied intravenously. The raw data were transferred to an external personal computer equipped with an image reconstruction software (CardioRecon 6; Siemens, Forchheim, Germany) to simulate 5 different dose levels. To simulate them correctly, a milliampere second-dependent noise was added to every image, so that the changes in a current- time product could be imitated. The images were compared in consensus by 2 radiologists who were not informed about the technical scanning parameters, that is, dose parameters, and were graded in 4 different subcategories on a 1-to-5-point scale. For statistical analysis, the Friedman test was used. Additional evaluations for lesions smaller than 1.0 cm were performed and analyzed separately. Results: For image noise, there was a significant change between 40 and 60 mA s. For lesion detection, there was no significant change. The contour of the small objects did not differ between 90, 60, and 40 mA s. However, a dose reduction to 30 mA s had a significant effect. The contrast did not differ between 90, 60, 40, and even down to 30 mA s. Only a maximal dose reduction to 20 mA s had a significant effect on the contrast. The level of noise was most sensitive to the current. Whereas a dose reduction to 60 mA s did not yet have a significant effect, there was a significant increase of noise at 40 mA s. Conclusions: The MSCT can be applied with a lower dose than that usually selected in examinations at present to follow-up and stage the oncological patients adequately.
引用
收藏
页码:302 / 308
页数:7
相关论文
共 50 条
  • [1] Low-dose radiation with 80-kVp computed tomography to diagnose pulmonary embolism: a feasibility study
    Nyman, Ulf
    Bjorkdahl, Peter
    Olsson, Marie-Louise
    Gunnarsson, Mikael
    Goldman, Bitte
    ACTA RADIOLOGICA, 2012, 53 (09) : 1004 - 1013
  • [2] Feasibility of ultra low-dose coronary computed tomography angiography
    McGraw, Sloane
    Carlson, Claire
    Grant, Katharine
    Nijjar, Prabhjot S.
    INDIAN HEART JOURNAL, 2018, 70 (03) : 443 - 445
  • [3] Low-dose computed tomography of urolithiasis in obese patients: a feasibility study to evaluate image reconstruction algorithms
    Chang, De-Hua
    Slebocki, Karin
    Khristenko, Ekaterina
    Herden, Jan
    Salem, Johannes
    Hokamp, Nils Grosse
    Mammadov, Kamal
    Hellmich, Martin
    Kabbasch, Christoph
    DIABETES METABOLIC SYNDROME AND OBESITY-TARGETS AND THERAPY, 2019, 12 : 439 - 445
  • [4] How to perform low-dose computed tomography for renal colic in clinical practice
    Gervaise, A.
    Gervaise-Henry, C.
    Pernin, M.
    Naulet, P.
    Junca-Laplace, C.
    Lapierre-Cornbes, M.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2016, 97 (04) : 393 - 400
  • [5] Low-Dose Computed Tomography Colonography Technique
    Chang, Kevin J.
    Yee, Judy
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (05) : 709 - +
  • [6] Low-dose Computed Tomography Screening in Japan
    Nawa, Takeshi
    Nakagawa, Tohru
    Mizoue, Tetsuya
    Endo, Katsuyuki
    JOURNAL OF THORACIC IMAGING, 2015, 30 (02) : 108 - 114
  • [7] Lung Cancer Screening with Low-Dose Computed Tomography
    Chiles, Caroline
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2014, 52 (01) : 27 - +
  • [8] Low-Dose Cardiovascular Computed Tomography: Where Are the Limits?
    Schoenhagen, Paul
    Thompson, Carla M.
    Halliburton, Sandra S.
    CURRENT CARDIOLOGY REPORTS, 2012, 14 (01) : 17 - 23
  • [9] Low-Dose Computed Tomography for Lung Cancer Screening: The Protocol and The Dose
    McDermott, Shaunagh
    Kaira, Mannudeep K.
    SEMINARS IN ROENTGENOLOGY, 2017, 52 (03) : 132 - 136
  • [10] Value of whole-body low-dose computed tomography in patients with ventriculoperitoneal shunts: a retrospective study
    Pala, Andrej
    Awad, Fadi
    Braun, Michael
    Hlavac, Michal
    Wunderlich, Arthur
    Schmitz, Bernd
    Wirtz, Christian Rainer
    Coburger, Jan
    JOURNAL OF NEUROSURGERY, 2018, 129 (06) : 1598 - 1603