Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China

被引:50
作者
Peng, Zhen [1 ]
Deng, Wu [1 ]
Tenorio, Rosangela [1 ]
机构
[1] Univ Nottingham Ningbo China, Dept Architecture & Built Environm, 199 Taikang East Rd, Ningbo 315100, Zhejiang, Peoples R China
关键词
indoor air quality; primary school; building air tightness; internal activities; air pollutants; PARTICULATE MATTER; VENTILATION RATES; PARTICLE SOURCES; SBS SYMPTOMS; OUTDOOR; CLASSROOM; POLLUTION; TEMPERATURE; PERFORMANCE; MECHANISMS;
D O I
10.3390/su9071180
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Over 70% of a pupil's school life is spent inside a classroom, and indoor air quality has a significant impact on students' attendance and learning potential. Therefore, the indoor air quality in primary school buildings is highly important. This empirical study investigates the indoor air quality in four naturally ventilated schools in China, with a focus on four parameters: PM2.5, PM10, CO2, and temperature. The correlations between the indoor air quality and the ambient air pollution, building defects, and occupants' activities have been identified and discussed. The results indicate that building defects and occupants' activities have a significant impact on indoor air quality. Buildings with better air tightness have a relatively smaller ratio of indoor particulate matter (PM) concentrations to outdoor PM concentrations when unoccupied. During occupied periods, the indoor/outdoor (I/O) ratio could be larger than 1 due to internal students' activities. The indoor air temperature in winter is mainly determined by occupants' activities and the adiabatic ability of a building's fabrics. CO2 can easily exceed 1000 ppm on average due to the closing of windows and doors to keep the inside air warmer in winter. It is concluded that improving air tightness might be a way of reducing outdoor air pollutants' penetration in naturally ventilated school buildings. Mechanical ventilation with air purification could be also an option on severely polluted days.
引用
收藏
页数:14
相关论文
共 35 条
[1]   Relative contribution of outdoor and indoor particle sources to indoor concentrations [J].
Abt, E ;
Suh, HH ;
Catalano, P ;
Koutrakis, P .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (17) :3579-3587
[2]   Sources of indoor and outdoor PM2.5 concentrations in primary schools [J].
Amato, F. ;
Rivas, I. ;
Viana, M. ;
Moreno, T. ;
Bouso, L. ;
Reche, C. ;
Alvarez-Pedrerol, M. ;
Alastuey, A. ;
Sunyer, J. ;
Querol, X. .
SCIENCE OF THE TOTAL ENVIRONMENT, 2014, 490 :757-765
[3]   Effects of pollution from personal computers on perceived air quality, SBS symptoms and productivity in offices [J].
Bakó-Biró, Z ;
Wargocki, P ;
Weschler, CJ ;
Fanger, PO .
INDOOR AIR, 2004, 14 (03) :178-187
[4]   Assessment of ventilation and indoor air pollutants in nursery and elementary schools in France [J].
Canha, N. ;
Mandin, C. ;
Ramalho, O. ;
Wyart, G. ;
Riberon, J. ;
Dassonville, C. ;
Hanninen, O. ;
Almeida, S. M. ;
Derbez, M. .
INDOOR AIR, 2016, 26 (03) :350-365
[5]   Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information [J].
Daisey, JM ;
Angell, WJ ;
Apte, MG .
INDOOR AIR, 2003, 13 (01) :53-64
[6]   Indoor and Outdoor Monitoring of Volatile Organic Compounds in School Buildings: Indicators Based on Health Risk Assessment to Single out Critical Issues [J].
de Gennaro, Gianluigi ;
Farella, Genoveffa ;
Marzocca, Annalisa ;
Mazzone, Antonio ;
Tutino, Maria .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2013, 10 (12) :6273-6291
[7]   Impact of indoor air temperature and humidity in an office on perceived air quality, SBS symptoms and performance [J].
Fang, L ;
Wyon, DP ;
Clausen, G ;
Fanger, PO .
INDOOR AIR, 2004, 14 :74-81
[8]  
Faustman EM, 2000, ENVIRON HEALTH PERSP, V108, P13, DOI 10.2307/3454629
[9]   Improving air pollution control policy in China-A perspective based on cost-benefit analysis [J].
Gao, Jinglei ;
Yuan, Zengwei ;
Liu, Xuewei ;
Xia, Xiaoming ;
Huang, Xianjin ;
Dong, Zhanfeng .
SCIENCE OF THE TOTAL ENVIRONMENT, 2016, 543 :307-314
[10]   Control of CO2 in a naturally ventilated classroom [J].
Griffiths, M. ;
Eftekhari, M. .
ENERGY AND BUILDINGS, 2008, 40 (04) :556-560