摘要
Heterogeneous ion-exchange membranes were prepared by mixing small particles of sulfonated poly(1,4-phenylene sulfide) or sulfonated styrene-divinylbenzene copolymer with a matrix polymer. Four kinds of polymers were tested as a matrix: highly flexible linear polyethylene, medium-flexible fluoroelastomer, rigid polystyrene (all highly hydrophobic) and hydrophilic cellulose prepared by hydrolysis of cellulose acetate butyrate. Membrane morphologies were studied by scanning electron microscopy, IR spectroscopy and density measurements. Subsequently, the membranes were characterised with respect to their swelling in water, electrochemical characteristics and transport properties. Ion-exchange capacity and proton conductivity together with the permeability to hydrogen and methanol were investigated. The important impact of the ion-exchange particles as well as of the polymer matrix used was observed. The increasing rigidity of the polymer matrix resulted in a decrease in membrane permeability, but at the same time in deterioration of its ion-exchange capacity and subsequently of the proton conductivity, too. This was explained in terms of the limited elasticity of the polymer matrix, in each sample under study, which does not allow the ion-exchange particles to swell to an identical degree.
引用
收藏
页码:1005 / 1018
页数:14
相关论文
共 50 条
  • [1] Heterogeneous ion-selective membranes: the influence of the inert matrix polymer on the membrane properties
    Karel Bouzek
    Sabina Moravcová
    Jan Schauer
    Libuše Brožová
    Zbyněk Pientka
    Journal of Applied Electrochemistry, 2010, 40 : 1005 - 1018
  • [2] THE DEVELOPMENT OF POLYMER MATRIX MEMBRANES FOR ION-SELECTIVE ELECTRODES
    MOODY, GJ
    SAAD, BB
    THOMAS, JDR
    SELECTIVE ELECTRODE REVIEWS, 1988, 10 (01): : 71 - 106
  • [3] MICROMACHINED ION-SELECTIVE ELECTRODES WITH POLYMER MATRIX MEMBRANES
    KNOLL, M
    CAMMANN, K
    DUMSCHAT, C
    ESHOLD, J
    SUNDERMEIER, C
    SENSORS AND ACTUATORS B-CHEMICAL, 1994, 21 (01) : 71 - 76
  • [4] Properties of ion-selective electrodes with polymer membranes for ibuprofen determination
    Lenik, J
    Marczewska, B
    Wardak, C
    DESALINATION, 2004, 163 (1-3) : 77 - 83
  • [5] EVALUATION OF POLY(VINYLIDENE CHLORIDE) AS A MATRIX FOR POLYMER MEMBRANE ION-SELECTIVE ELECTRODES
    WOTRING, VJ
    PRINCE, PK
    BACHAS, LG
    ANALYST, 1991, 116 (06) : 581 - 584
  • [6] Influence of plasticizers on ion-selective polyimide membranes
    Totu, Eugenia
    Ruse, Elena
    Josceanu, Ana Maria
    ANNALI DI CHIMICA, 2006, 96 (3-4) : 237 - 246
  • [7] Basic analysis on the origin of asymmetry potentials observed with ion-selective polymer matrix membranes
    Schwake, A
    Ross, B
    Cammann, K
    SENSORS AND ACTUATORS B-CHEMICAL, 1998, 48 (1-3) : 251 - 257
  • [8] Basic analysis on the origin of asymmetry potentials observed with ion-selective polymer matrix membranes
    Schwake, A.
    Ross, B.
    Cammann, K.
    Sensors and Actuators, B: Chemical, 1998, B48 (1 -3 pt 4): : 251 - 257
  • [9] Filled fluorosilicone as matrix material for ion-selective membranes
    Dumschat, C
    Alazard, S
    Adam, S
    Knoll, M
    Cammann, K
    ANALYST, 1996, 121 (04) : 527 - 529
  • [10] ION-SELECTIVE MEMBRANES
    SIMON, W
    AMMANN, D
    MORF, WE
    OESCH, U
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1984, 31 (08) : 584 - 584