作者
Doroshenko, VM [1 ]
Cotter, RJ [1 ]
机构
[1] JOHNS HOPKINS UNIV,SCH MED,DEPT PHARMACOL & MOLEC SCI,MIDDLE ATLANTIC MASS SPECTROMETRY LAB,BALTIMORE,MD 21205
关键词
D O I
10.1021/ac950954l
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A pulsed valve was used for studying the effects of introducing heavy gases at different stages of operation of a quadrupole ion trap and for increasing the efficiency of collision-induced dissociation (CID) of peptide ions at low values of the Mathieu parameter q(z), When amounts of heavy gases comparable to that of the helium buffer gas were introduced during the ion trapping, ion isolation, and mass spectral recording stages, the effects on performance were generally small or negative. However, injection of heavy gases during CID provided considerable improvement in fragmentation efficiency that depended upon the particular gas used, its mass and pressure, and the amplitude of the excitation voltage, Efficient peptide fragmentation could be demonstrated for values of q(z) as low as 0.05, which permitted trapping of low-mass product ions and (in many cases) full recovery of the amino acid sequence, In this report, examples are provided of monoisotopic tandem mass spectra of peptide ions with masses up to 1570 Da.
引用
收藏
页码:463 / 472
页数:10
相关论文
共 33 条
[1]  
[Anonymous], [No title captured]
[2]   ENERGY-RESOLVED COLLISIONAL ACTIVATION OF DIMETHYL PHOSPHONATE AND DIMETHYL PHOSPHITE IONS IN A QUADRUPOLE ION TRAP AND A TRIPLE QUADRUPOLE MASS-SPECTROMETER [J].
BRODBELT, JS ;
KENTTAMAA, HI ;
COOKS, RG .
ORGANIC MASS SPECTROMETRY, 1988, 23 (01) :6-9
[3]   PULSED VALVE ADDITION OF COLLISION AND REAGENT GASES IN FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
CARLIN, TJ ;
FREISER, BS .
ANALYTICAL CHEMISTRY, 1983, 55 (03) :571-574
[4]   COMPETITION BETWEEN RESONANCE EJECTION AND ION DISSOCIATION DURING RESONANT EXCITATION IN A QUADRUPOLE ION-TRAP [J].
CHARLES, MJ ;
MCLUCKEY, SA ;
GLISH, GL .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (12) :1031-1041
[5]   QUADRUPOLE ION TRAP MASS-SPECTROMETRY - CURRENT APPLICATIONS AND FUTURE-DIRECTIONS FOR PEPTIDE ANALYSIS [J].
COX, KA ;
WILLIAMS, JD ;
COOKS, RG ;
KAISER, RE .
BIOLOGICAL MASS SPECTROMETRY, 1992, 21 (05) :226-241
[6]   HIGH-PERFORMANCE COLLISION-INDUCED DISSOCIATION OF PEPTIDE IONS FORMED BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION IN A QUADRUPOLE ION-TRAP MASS-SPECTROMETER [J].
DOROSHENKO, VM ;
COTTER, RJ .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :2180-2187
[7]   LINEAR MASS CALIBRATION IN THE QUADRUPOLE ION-TRAP MASS-SPECTROMETER [J].
DOROSHENKO, VM ;
COTTER, RJ .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (09) :766-776
[8]   MATRIX-ASSISTED LASER DESORPTION IONIZATION INSIDE A QUADRUPOLE ION-TRAP DETECTOR CELL [J].
DOROSHENKO, VM ;
CORNISH, TJ ;
COTTER, RJ .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (12) :753-757
[9]   A NEW METHOD OF TRAPPING IONS PRODUCED BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION IN A QUADRUPOLE ION-TRAP [J].
DOROSHENKO, VM ;
COTTER, RJ .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (09) :822-827
[10]  
DOROSHENKO VM, IN PRESS RAPID COMMU