Integral imaging with improved depth of field by use of amplitude-modulated microlens arrays

被引:116
|
作者
Martínez-Corral, M
Javidi, B
Martínez-Cuenca, R
Saavedra, G
机构
[1] Univ Connecticut, Dept Elect & Comp Engn, Storrs, CT 06269 USA
[2] Univ Valencia, Dept Opt, E-46100 Burjassot, Spain
关键词
D O I
10.1364/AO.43.005806
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
One of the main challenges in three-dimensional integral imaging is its limited depth of field. Such a limitation is imposed by diffraction, among other factors. The easiest way to improve the depth of field is by reducing the numerical aperture of the microlenses. However, such an improvement is obtained at the expense of an important deterioration in the spatial resolution. We propose a technique, which is novel in the context of integral imaging, for improving the depth of field with no deterioration of the spatial resolution. The technique, based on amplitude modulation of the array of phase elements, can substantially improve the figure of merit of the product of depth of the focus and the squared resolution. (C) 2004 Optical Society of America.
引用
收藏
页码:5806 / 5813
页数:8
相关论文
共 50 条
  • [1] Extended depth-of-field in integral-imaging pickup process based on amplitude-modulated sensor arrays
    Luo, Cheng-Gao
    Wang, Qiong-Hua
    Deng, Huan
    Liu, Yao
    OPTICAL ENGINEERING, 2015, 54 (07)
  • [2] Microlens arrays for integral imaging system
    Arai, Jun
    Kawai, Hiroshi
    Okano, Fumio
    APPLIED OPTICS, 2006, 45 (36) : 9066 - 9078
  • [3] Microlens arrays for integral imaging system
    Arai, Jun
    Kawai, Hiroshi
    Okano, Fumio
    NHK Laboratories Note, 2007, (510): : 9056 - 9078
  • [4] POLARIZATION OF A MEDIUM IN AN AMPLITUDE-MODULATED ELECTROMAGNETIC FIELD
    YANKAUSK, ZK
    SOVIET PHYSICS TECHNICAL PHYSICS-USSR, 1969, 13 (11): : 1506 - &
  • [5] STARK-EFFECT IN AN AMPLITUDE-MODULATED FIELD
    BYKOVSKII, VT
    OSELEDCHIK, YS
    KHALADZHI, VG
    OPTIKA I SPEKTROSKOPIYA, 1975, 38 (03): : 486 - 492
  • [6] Imaging properties of microlens arrays for integral imaging system
    Arai, Jun
    Okui, Makoto
    Nojiri, Yuji
    Okano, Fumio
    STEREOSCOPIC DISPLAYS AND VIRTUAL REALITY SYSTEMS XIII, 2006, 6055
  • [7] CESR OBSERVATION USING AN AMPLITUDE-MODULATED MICROWAVE FIELD
    VIGOUROUX, B
    GOURDON, JC
    PESCIA, J
    JOURNAL OF PHYSICS F-METAL PHYSICS, 1976, 6 (08): : 1575 - 1582
  • [8] Characterisation of microlens arrays for integral field spectroscopy.
    Lee, D
    Allington-Smith, JR
    Content, R
    Haynes, R
    OPTICAL ASTRONOMICAL INSTRUMENTATION, PTS 1 AND 2, 1998, 3355 : 810 - 820
  • [9] SNIFS :: a wideband integral field spectrograph with microlens arrays
    Lantz, B
    Aldering, G
    Antilogus, P
    Bonnaud, C
    Capoani, L
    Castera, A
    Copin, Y
    Dubet, D
    Gangler, E
    Hénault, F
    Lemonnier, JP
    Pain, R
    Pécontal, A
    Pécontal, E
    Smadja, G
    OPTICAL DESIGN AND ENGINEERING, 2004, 5249 : 146 - 155
  • [10] USE OF AMPLITUDE-MODULATED FOCUSED ULTRASOUND FOR DIAGNOSIS OF HEARING DISORDERS
    TSIRULNIKOV, EM
    VARTANYAN, IA
    GERSUNI, GV
    ROSENBLYUM, AS
    PUDOV, VI
    GAVRILOV, LR
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1988, 14 (04) : 277 - 285