摘要
Background. Complex aortic arch disease can be a formidable challenge and is often treated with a twostage elephant trunk technique. We examined our experience with hybrid arch repair with combined zone 0 stent graft deployment. Methods. A retrospective review was conducted of all patients who underwent type 2 hybrid arch replacement and zone 0 antegrade endovascular stent graft deployments at a single university center from June 2010 to August 2015. Results. The review included 48 patients, 25 (52%) elective and 23 (48%) nonelective, with a mean +/- SD age of 64 +/- 11 years. Overall in-hospital mortality was 17% (8 of 48). Age exceeding 65 years (odds ratio, 9.5; 95% confidence interval, 1.2 to 36), preoperative international normalized ratio exceeding 1.3 (odds ratio, 14.2; 95% confidence interval, 2.1 to 95.87), and postoperative acute kidney injury (odds ratio, 5.6; 95% confidence interval, 1.1 to 29) were associated with in-hospital death. Postoperative stroke occurred in 3 patients (6%) and permanent paraplegia in 1 patient (2%). One (2%) patient underwent reoperation due to bleeding, and 6 patients (13%) experienced respiratory failure/reintubation. Acute kidney injury developed in 12 patients (25%), according to Acute Kidney Injury Network criteria, with 7 (14.6%) at stage 1 and 5 (10.4%) at stage 3. At the 1-year follow-up, type II endoleak developed in 2 of the 40 patients (5%), and 2 others required reoperation due to progression of chronic aortic dissection. Median follow-up time was 17 months (range, 1 to 63 months). The overall survival rate was 92% +/- 0.04% at 6 months and 89% +/- 0.05% at 1 and at 3 years. Conclusions. Hybrid repair of complex aortic arch pathology with antegrade stent graft deployment can be performed safely with high technical success while obviating the need for a second operation. Reasonable midterm survival can be anticipated; however, older age, preoperative coagulopathy, and postoperative acute kidney injury are factors associated with poor outcome. (C) 2017 by The Society of Thoracic Surgeons
引用
收藏
页码:538 / 544
页数:7
相关论文
共 40 条
[1]   Midterm Results of Endovascular Stent Grafts in the Proximal Aortic Arch (Zone 0): An Imaging Perspective [J].
Appoo, Jehangir J. ;
Herget, Eric J. ;
Pozeg, Zlatko I. ;
Ferris, Mollie C. ;
Wong, Jason K. ;
Gregory, Alex J. ;
Gupta, Arjun K. ;
Merchant, Naeem ;
Kent, William D. T. .
CANADIAN JOURNAL OF CARDIOLOGY, 2015, 31 (06) :731-737
[2]  
Bagshaw SM, 2010, CAN J ANESTH, V57, P985, DOI 10.1007/s12630-010-9375-4
[3]   Thoracic Endovascular Aortic Repair of Aortic Arch Pathologies with the Conformable Thoracic Aortic Graft: Early and 2 year Results from a European Multicentre Registry [J].
Boeckler, D. ;
Brunkwall, J. ;
Taylor, P. R. ;
Mangialardi, N. ;
Huesing, J. ;
Larzon, T. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2016, 51 (06) :791-800
[4]   EXTENSIVE AORTIC REPLACEMENT USING ELEPHANT TRUNK PROSTHESIS [J].
BORST, HG ;
WALTERBUSCH, G ;
SCHAPS, D .
THORACIC AND CARDIOVASCULAR SURGEON, 1983, 31 (01) :37-40
[5]   Systematic review of clinical outcomes in hybrid procedures for aortic arch dissections and other arch diseases [J].
Cao, Piergiorgio ;
De Rango, Paola ;
Czerny, Martin ;
Evangelista, Arturo ;
Fattori, Rossella ;
Nienaber, Christoph ;
Rousseau, Herve ;
Schepens, Marc .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 144 (06) :1286-+
[6]  
Cappabianca G, 2016, 52 ANN M SOC THOR SU
[7]   Total Arch Repair for Acute Type A Aortic Dissection With 2 Modified Techniques: Open Single-Branched Stent Graft Placement and Reinforcement of the Dissected Arch Vessel Stump With Stent Graft [J].
Chen, Liang-Wan ;
Wu, Xi-Jie ;
Lu, Lin ;
Zhang, Gui-Can ;
Yang, Guo-Feng ;
Yang, Zhao-Wei ;
Dong, Yi ;
Cao, Hua ;
Chen, Qiang .
CIRCULATION, 2011, 123 (22) :2536-2541
[8]   Endovascular therapy of thoracic aneurysms: Gore TAG trial results [J].
Cho, Jae-Sung ;
Haider, Shan-e-ali ;
Makaroun, Michel S. .
SEMINARS IN VASCULAR SURGERY, 2006, 19 (01) :18-24
[9]   Distal Aortic Remodeling Using Endovascular Repair in Acute DeBakey I Aortic Dissection [J].
Desai, Nimesh D. ;
Pochettino, Alberto .
SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2009, 21 (04) :387-392
[10]   Complex thoracic aortic disease: Single-stage procedure with the frozen elephant trunk technique [J].
Di Bartolomeo, Roberto ;
Pacini, Davide ;
Savini, Carlo ;
Pilato, Emanuele ;
Martin-Suarez, Sofia ;
Di Marco, Luca ;
Di Eusanio, Marco .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 140 (06) :S81-S85