Frequency-selective signal enhancement by a passive dual coil resonator for magnetic particle imaging

被引:9
|
作者
Pantke, Dennis [1 ]
Mueller, Florian [1 ]
Reinartz, Sebastian [2 ]
Philipps, Jonas [1 ]
Dadfar, Seyed Mohammadali [3 ]
Peters, Maximilian [1 ]
Franke, Jochen [1 ,4 ]
Schrank, Franziska [1 ]
Kiessling, Fabian [3 ,5 ]
Schulz, Volkmar [1 ,5 ,6 ]
机构
[1] Rhein Westfal TH Aachen, Inst Expt Mol Imaging, Dept Phys Mol Imaging, Aachen, Germany
[2] Uniklin RWTH Aachen, Dept Diagnost & Intervent Radiol, Aachen, Germany
[3] Rhein Westfal TH Aachen, Med Fac, Inst Expt Mol Imaging, Aachen, Germany
[4] Bruker BioSpin MRI GmbH, Preclin Imaging Div, Ettlingen, Germany
[5] Fraunhofer Inst Digital Med MEVIS, Bremen, Germany
[6] Rhein Westfal TH Aachen, Phys Inst B 3, Aachen, Germany
关键词
magnetic particle imaging; passive receive coil; signal enhancement; SYSTEM; RECONSTRUCTION; HYPERTHERMIA; FEASIBILITY; FORMULATION; RESOLUTION;
D O I
10.1088/1361-6560/ac6a9f
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Magnetic particle imaging (MPI) visualizes the spatial distribution of magnetic nanoparticles. MPI already provides excellent temporal and good spatial resolution, however, to achieve translation into clinics, further advances in the fields of sensitivity, image reconstruction and tracer performance are needed. In this work, we propose a novel concept to enhance the MPI signal and image resolution by a purely passive receive coil insert for a preclinical MPI system. Approach. The passive dual coil resonator (pDCR) provides frequency-selective signal enhancement. This is enabled by the adaptable resonance frequency of the pDCR network, which is galvanically isolated from the MPI system and composed of two coaxial solenoids connected via a capacitor. The pDCR aims to enhance frequency components related to high mixing orders, which are crucial to achieve high spatial resolution. Main Results. In this study, system matrix measurements and image acquisitions of a resolution phantom are carried out to evaluate the performance of the pDCR compared to the integrated receive unit of the preclinical MPI and a dedicated rat-sized receive coil. Frequency-selective signal increase and spatial resolution enhancement are demonstrated. Significance. Common dedicated receive coils come along with noise-matched receive networks, which makes them costly and difficult to reproduce. The presented pDCR is a purely passive coil insert that gets along without any additional receive electronics. Therefore, it is cost-efficient, easy-to-handle and adaptable to other MPI scanners and potentially other applications providing the basis for a new breed of passive MPI receiver systems.
引用
收藏
页数:12
相关论文
共 47 条
  • [1] Dual-frequency magnetic particle imaging of the Brownian particle contribution
    Viereck, Thilo
    Kuhlmann, Christian
    Draack, Sebastian
    Schilling, Meinhard
    Ludwig, Frank
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2017, 427 : 156 - 161
  • [2] Frequency-Hopped Signal Source Identification in Frequency-Selective Channels
    Loof, Joseph L.
    Pratt, Thomas G.
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 2019, 55 (06) : 3316 - 3329
  • [3] RECEIVE COIL ARRAY FOR MAGNETIC PARTICLE IMAGING
    Knopp, Tobias
    Sattel, Timo F.
    Biederer, Sven
    Weizenecker, Juergen
    Gleich, Bernhard
    Borgert, Joern
    Buzug, Thorsten M.
    2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 1666 - 1669
  • [4] Magnetic particle imaging deblurring with dual contrastive learning and adversarial framework
    Zhang, Jiaxin
    Wei, Zechen
    Wu, Xiangjun
    Shang, Yaxin
    Tian, Jie
    Hui, Hui
    COMPUTERS IN BIOLOGY AND MEDICINE, 2023, 165
  • [5] Dual-Feature Frequency Component Compression Method for Accelerating Reconstruction in Magnetic Particle Imaging
    Zhang, Peng
    Liu, Jie
    Li, Yimeng
    Yin, Lin
    An, Yu
    Zhong, Jing
    Hui, Hui
    Tian, Jie
    IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2023, 9 : 289 - 297
  • [6] Analog receive signal processing for magnetic particle imaging
    Graeser, Matthias
    Knopp, Tobias
    Gruettner, Mandy
    Sattel, Timo F.
    Buzug, Thorsten M.
    MEDICAL PHYSICS, 2013, 40 (04)
  • [7] Multi-scale dual domain network for nonlinear magnetization signal filtering in magnetic particle imaging
    Peng, Huiling
    Wei, Zechen
    Li, Yimeng
    Zhu, Tao
    Wang, Tan
    Fan, Zhan
    Yang, Xin
    Tian, Jie
    Hui, Hui
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 85
  • [8] An Improved Design of Detection Coil for Magnetic Particle Imaging
    Zhang, Rui
    Sun, Shijie
    Sun, Shaoqi
    Wei, Jian
    Li, Xingang
    Zhong, Jing
    Xu, Lijun
    2023 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, I2MTC, 2023,
  • [9] BSS-TFNet: Attention-Enhanced Background Signal Suppression Network for Time-Frequency Spectrum in Magnetic Particle Imaging
    Wei, Zechen
    Liu, Yanjun
    Zhu, Tao
    Yang, Xin
    Tian, Jie
    Hui, Hui
    IEEE TRANSACTIONS ON EMERGING TOPICS IN COMPUTATIONAL INTELLIGENCE, 2024, 8 (02): : 1322 - 1336
  • [10] Transverse MNP Signal-Based Isotropic Imaging for Magnetic Particle Imaging
    Li, Lei
    Liao, Yidong
    Wang, Qibin
    Zhang, Zhonghao
    Ge, Dawei
    Hu, Jiawei
    He, Ning
    Liu, Yanjun
    Xu, Chenxiao
    Gao, Yunpeng
    Guo, Pengyue
    Hui, Hui
    Feng, Xin
    Zhu, Shouping
    Tian, Jie
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 13