Never drop your guard down after atrial septal defect closure: a case report

被引:5
作者
Bergonti, Marco [1 ]
Toscano, Olga [1 ]
Teruzzi, Giovanni [1 ]
Trabattoni, Daniela [1 ]
机构
[1] IRCCS, Ctr Cardiol Monzino, Dept Cardiovasc Sci, Via Carlo Parea 4, I-20138 Milan, Italy
关键词
Atrial septal defect; Atrial septal erosion; Aortic rim; Septal occlude; Device dislodgement; Late complications; Case report;
D O I
10.1093/ehjcr/ytz094
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Percutaneous atrial septal defect (ASD) closure carries a not negligible burden of complications, such as the erosion of cardiac structures surrounding the device. Complications related to erosion are rare and often occur during the first 6 months after implantation. Case summary A 40-year-old female patient underwent percutaneous ASD closure in 2006. After 12 years of uneventful follow-up, in March 2018, a device dislodgement causing atrial shunting was incidentally discovered and was attributed to device-induced atrial septal erosion. The patient successfully underwent surgical removal of the device and correction of the interatrial defect. Discussion Our purpose is to underline the importance of staged long-term imaging follow-up, even many years after a successful procedure and to highlight the possible risk factors leading to this worrisome condition. In addition, we sought to underline the possible risks associated with deficient aortic rim and explain pros and cons of different approaches.
引用
收藏
页数:4
相关论文
共 6 条
  • [1] Erosion of amplatzer septal occluder device after closure of secundum atrial septal defects: Review of registry of complications and recommendations to minimize future risk
    Amin, Z
    Hijazi, ZM
    Bass, JL
    Cheatham, JP
    Hellenbrand, WE
    Kleinman, CS
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 63 (04) : 496 - 502
  • [2] Erosion by the Amplatzer Septal Occluder: Experienced Operator Opinions at Odds With Manufacturer Recommendations?
    El-Said, Howaida G.
    Moore, John W.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 73 (07) : 925 - 930
  • [3] Very late erosion of Amplatzer occluder device resulting in Cardiac tamponade after 15 years
    Guelker, Jan-Erik
    Jansen, Ruben
    Sievert, Kolja
    Sievert, Horst
    Bertog, Stefan
    [J]. CLINICAL RESEARCH IN CARDIOLOGY, 2018, 107 (06) : 527 - 529
  • [4] Long-Term Follow-Up of Large Atrial Septal Occluder (Amplatzer Device) With Cardiac MRI in a Pediatric Population
    Lapierre, Chantale
    Hugues, Nicolas
    Dahdah, Nagib
    Dery, Julie
    Raboisson, Marie-Josee
    Miro, Joaquim
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : 1136 - 1141
  • [5] Transcatheter Device Closure of Atrial Septal Defects A Safety Review
    Moore, John
    Hegde, Sanjeet
    El-Said, Howaida
    Beekman, Robert, III
    Benson, Lee
    Bergersen, Lisa
    Holzer, Ralf
    Jenkins, Kathy
    Ringel, Richard
    Rome, Jonathan
    Vincent, Robert
    Martin, Gerard
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (05) : 433 - 442
  • [6] Addressing the needs of treating congenital heart disease: The influence of deficient retro-aortic rim on technical success and early adverse events following device closure of secundum atrial septal defects: An analysis of the IMPACT registry®
    Tobis, Jonathan M.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 89 (01) : 112 - 113