Arrester Damage on 6.6 kV Power Distribution Line in Japan by Winter Lightning

被引:0
|
作者
Michishita, Koji [1 ]
Omura, Takuya [1 ]
Yokoyama, Shigeru [1 ]
Takano, Koji [2 ]
Ikuta, Masateru [2 ]
Matsui, Michihiro [3 ]
机构
[1] Shizuoka Univ, Dept Elect & Elect Engn, Hamamatsu, Shizuoka, Japan
[2] Kyushu Elect Power Co, Res Lab, Fukuoka, Japan
[3] Franklin Japan Co, Engn Div, Sagamihara, Kanagawa, Japan
关键词
surge arrester; winter lightning; OPDL (overhead power distribution line); lightning fault; SEA;
D O I
10.1109/ICLPANDSIPDA54065.2021.9627344
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The proportion of lightning fault among distribution line faults is still high, and lightning protection of an OPDL (overhead power distribution line) are still an important issue even today. In this paper, the authors investigate the arrester damage on the OPDL in Japan by winter lightning.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Response of a Surge Arrester With a Series Gap for 6.6-kV Distribution Lines to Steep-Front Transients
    Mori, Ryota
    Tatematsu, Akiyoshi
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2022, 64 (06) : 2296 - 2300
  • [22] Development of Current Limiting Arcing Horn (MOV type arrester with external gap) for 22 kV power distribution line
    Hashimoto, Yousuke
    Fukui, Hiroshi
    Yano, Toshihiro
    Tsukazaki, Minoru
    Sakakiwara, Masahiro
    ELECTRIC POWER SYSTEMS RESEARCH, 2013, 94 : 129 - 133
  • [24] Application of 10kV Post-arrester in Protection from induced-Lightning in Distribution Network
    Tu Jun
    Zhou Wen-jun
    Yu Jian-hui
    2010 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY & TECHNICAL EXHIBITION ON EMC RF/MICROWAVE MEASUREMENTS & INSTRUMENTATION, 2010, : 1547 - 1549
  • [25] Development and Application of ±500 kV DC Transmission Line Arrester in China Power Grid
    Gu, Shanqiang
    Wan, Shuai
    Wang, Jian
    Chen, Jiahong
    Li, Tao
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (01) : 209 - 217
  • [26] Lightning induced voltages on multiconductor power distribution line
    Kannu, PD
    Thomas, MJ
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2005, 152 (06) : 855 - 863
  • [27] Economic Assessment of Lightning Performance Improvement of 69 kV Subtransmission Line in MEA's Power Distribution System
    Phayomhom, A.
    Sirisumrannukul, S.
    Kasirawat, T.
    Puttarach, A.
    2014 INTERNATIONAL ELECTRICAL ENGINEERING CONGRESS (IEECON), 2014,
  • [28] Optimization of the 110 kV power distribution line
    Buchta, Franciszek
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (08): : 104 - 107
  • [29] Three-phase overvoltage at lightning strike point due to direct triggered lightning to the phase wire of 10 kV power distribution line
    Wang, Jianguo
    Zhao, Yating
    Cai, Li
    Fang, Yuqian
    Li, Quanxin
    Su, Rui
    Wang, Shoupeng
    Zhou, Mi
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2022, 16 (11) : 2188 - 2197
  • [30] Distribution arrester outages caused by lightning backflow current flowing from customer's facility into power distribution lines
    Nakada, K
    Yokota, T
    Yokoyama, S
    Asakawa, A
    Kawabata, T
    ELECTRICAL ENGINEERING IN JAPAN, 1999, 126 (03) : 9 - 20