Simultaneous determination of adenosine and adenosine-5′-triphosphate at nanogold modified indium tin oxide electrode by osteryoung square-wave voltammetry

被引:30
作者
Goyal, Rajendra N. [1 ]
Oyama, Munetaka
Singh, Sudhanshu P.
机构
[1] Indian Inst Technol, Dept Chem, Roorkee 247667, Uttar Pradesh, India
[2] Int Innovat Ctr, Div Res Initiat, Nishikyo Ku, Kyoto 6158520, Japan
关键词
gold nanoparticles; electrocatalysis; osteryoung square-wave voltammetry; adenosine; adenosine-5 '-triphosphate;
D O I
10.1002/elan.200603766
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Simultaneous determination of adenosine and adenosine-5'-triphosphate has been described using nanogold modified indium tin oxide electrode. Gold nanoparticles catalyze adenosine oxidation which results in increasing separation of oxidation peaks of adenosine and ATP, making it possible to determine adenosine and adenosine-5'-triphosphate simultaneously. The detection limits for adenosine and ATP were found as 0.07 mu M and 0.10 mu M respectively with sensitivity 22.9 nA mu M-1 and 20.9 nA mu M-1. The proposed method was also used for sensing the compounds in biological samples. Influence of various square-wave parameters and different pH conditions on peak current has also been reported.
引用
收藏
页码:575 / 581
页数:7
相关论文
共 25 条
  • [1] Development of adenosine sensor: effect of physiological buffers on activity and sensitivity in adenosine determinations by fast scan voltammetry
    Abou El-Nour, K
    Brajter-Toth, A
    [J]. ANALYST, 2003, 128 (08) : 1056 - 1061
  • [2] Assembly of dendrimers with redox-active [{CpFe(μ3-CO)}4] clusters at the periphery and their application to oxo-anion and adenosine-5′-triphosphate sensing
    Aranzaes, JR
    Belin, C
    Astruc, D
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2006, 45 (01) : 132 - 136
  • [3] Glutamate neurotoxicity, oxidative stress and mitochondria
    Atlante, A
    Calissano, P
    Bobba, A
    Giannattasio, S
    Marra, E
    Passarella, S
    [J]. FEBS LETTERS, 2001, 497 (01) : 1 - 5
  • [4] THE ROLE OF ADENOSINE IN THE REGULATION OF CORONARY BLOOD-FLOW
    BERNE, RM
    [J]. CIRCULATION RESEARCH, 1980, 47 (06) : 807 - 813
  • [5] An improved capillary electrophoresis method for measuring tissue metabolites associated with cellular energy state
    Casey, TM
    Dufall, KG
    Arthur, PG
    [J]. EUROPEAN JOURNAL OF BIOCHEMISTRY, 1999, 261 (03): : 740 - 745
  • [6] Christian G.D., 1962, JELECTROANAL CHEM, V3, P363, DOI [10.1016/0022-0728(62)80012-6, DOI 10.1016/0022-0728(62)80012-6]
  • [7] Delayed production of adenosine underlies temporal modulation of swimming in frog embryo
    Dale, N
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1998, 511 (01): : 265 - 272
  • [8] Spatial heterogeneity of blood flow in the dog heart .2. Temporal stability in response to adrenergic stimulation
    Deussen, A
    Flesche, CW
    Lauer, T
    Sonntag, M
    Schrader, J
    [J]. PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1996, 432 (03): : 451 - 461
  • [9] FUKUNAGA AF, Patent No. 6642209
  • [10] Goyal RN, 2005, INDIAN J CHEM A, V44, P945