Capacitively Coupled Electrocardiogram Measuring System and Noise Reduction by Singular Spectrum Analysis

被引:44
作者
Yang, Bin [1 ]
Yu, Chunyang [2 ]
Dong, Yonggui [1 ]
机构
[1] Tsinghua Univ, Dept Precis Instruments, Beijing 100084, Peoples R China
[2] Beijing Jiaotong Univ, Sch Mech Elect & Control Engn, Beijing 100044, Peoples R China
基金
中国国家自然科学基金;
关键词
ECG signal; capacitively-coupled electrode; wearable device; singular spectrum analysis; ECG-derivation respiration;
D O I
10.1109/JSEN.2016.2532599
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A wearable electrocardiogram (ECG) measuring system is designed based upon capacitively coupled biopotential sensing electrodes. The sensing electrodes are made from the standard printed-circuit board. Using a reversely connected diode to provide the required high-value bias resistance, the pickup circuit for biopotential sensing is implemented by a high-input-impedance instrumentation amplifier. Two different configurations of the ECG measuring system are constructed and experimentally tested. One is a floating ground configuration in which only two sensing electrodes are used for ECG signal acquisition. Another is the passive ground configuration in which an additional grounding electrode is employed as the reference for common-mode noise suppression. The ECG signal can be obtained through thin clothes for both cases but performs lower signal-to-noise ratio. In order to improve the quality of the obtained signal, an algorithm based on a singular spectrum analysis is designed for noise reduction. A matching template is introduced to pick out the critical principal components automatically. Experimental results show that, with the aid of the proposed algorithm, satisfied ECG and respiration signals can be effectively obtained outside cotton-fiber clothing.
引用
收藏
页码:3802 / 3810
页数:9
相关论文
共 25 条
[1]  
Aleksandrowicz A, 2007, ACTA POLYTECH, V47, P68
[2]   A Smart Health Monitoring Chair for Nonintrusive Measurement of Biological Signals [J].
Baek, Hyun Jae ;
Chung, Gih Sung ;
Kim, Ko Keun ;
Park, Kwang Suk .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2012, 16 (01) :150-158
[3]  
Chi Y.M., 2010, Wireless Health, P15, DOI [DOI 10.1145/1921081.1921085, 10.3390/s22031010, DOI 10.3390/S22031010]
[4]   Dry and Noncontact EEG Sensors for Mobile Brain-Computer Interfaces [J].
Chi, Yu Mike ;
Wang, Yu-Te ;
Wang, Yijun ;
Maier, Christoph ;
Jung, Tzyy-Ping ;
Cauwenberghs, Gert .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2012, 20 (02) :228-235
[5]  
Ding S., 2004, International Journal of Bioelectromagnetism, V6, P43
[6]  
Faggion L, 2011, IEEE SENSOR, P296
[7]   Non-contact imaging of carbon composite structures using electric potential (displacement current) sensors [J].
Gebrial, W. ;
Prance, R. J. ;
Harland, C. J. ;
Stiffell, P. B. ;
Prance, H. ;
Clark, T. D. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (06) :1470-1476
[8]   Localizing Heart Sounds in Respiratory Signals Using Singular Spectrum Analysis [J].
Ghaderi, Foad ;
Mohseni, Hamid R. ;
Sanei, Saeid .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (12) :3360-3367
[9]  
Ianov A. I., 2012, Proceedings of the 2012 ICME International Conference on Complex Medical Engineering (CME), P593, DOI 10.1109/ICCME.2012.6275720
[10]   Non-contact heart rate and heart rate variability measurements: A review [J].
Kranjec, J. ;
Begus, S. ;
Gersak, G. ;
Drnovsek, J. .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2014, 13 :102-112