The reliability and validity of passive leg raise and fluid bolus to assess fluid responsiveness in spontaneously breathing emergency department patients

被引:30
作者
Duus, Nicolaj [1 ,2 ]
Shogilev, Daniel J. [5 ]
Skibsted, Simon [1 ,2 ]
Zijlstra, Hendrik W. [1 ]
Fish, Emily [3 ]
Oren-Grinberg, Achikam [3 ]
Lior, Yotam [4 ]
Novack, Victor [4 ]
Talmor, Daniel [3 ]
Kirkegaard, Hans [2 ]
Shapiro, Nathan I. [1 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Emergency Med, Boston, MA 02215 USA
[2] Aarhus Univ Hosp, Res Ctr Emergency Med, DK-8000 Aarhus, Denmark
[3] Beth Israel Deaconess Med Ctr, Dept Anesthesia Crit Care & Pain Med, Boston, MA 02215 USA
[4] Ben Gurion Univ Negev, Fac Hlth Sci, Soroka Univ Med Ctr, Clin Res Ctr, Beer Sheva, Israel
[5] Duke Univ, Div Emergency Med, Durham, NC USA
关键词
Fluid resuscitation; Noninvasive monitoring; Passive leg raise; Fluid bolus; Fluid responsiveness; CARDIAC-OUTPUT; PRESSURE; BIOREACTANCE; DOPPLER; FLOTRAC;
D O I
10.1016/j.jcrc.2014.07.031
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: We investigated the reproducibility of passive leg raise (PLR) and fluid bolus (BOLUS) using the Non-Invasive Cardiac Output Monitor (NICOM; Cheetah Medical, Tel Aviv, Israel) for assessment of fluid responsiveness (FR) in spontaneously breathing emergency department (ED) patients. Methods: Prospective, observational study of a convenience sample of adult ED patients receiving intravenous fluid bolus. We assessed stroke volume (SV) using NICOM and obtained results from PLR, where the head of the bed was changed from semirecumbent to supine while the patients' legs raised to 45 degrees for 3 minutes. Fluid bolus was defined as 5 mL/kg normal saline infusion. Maximal increase in SV was recorded. Fluid responsiveness was defined as an increase of SV greater than 10% from baseline. We obtained 4 consecutive responses for each patient; PLR1, PLR2, BOLUS1 separated each by 10 minutes, and BOLUS2 initiated immediately after the end of BOLUS1. We calculated. statistics, correlation coefficients, and odds ratios with 95% confidence interval and Bland-Altman plots. Results: We enrolled 109 patients enrolled in this study. The 2 PLRs were significantly correlated (r = 0.78, P < .001) with kappa = 0.46 for FR(P < .001). The 2 BOLUSES less strongly correlated (r = 0.14, P = .001) and kappa = 0.06 for FR (P < .001). Patients who were responsive to PLR1 had 9.5 (3.6-25) odds of being FR for PLR2, whereas those responsive to BOLUS1 had a 1.8 (0.76-4.3) increased odds of FR for BOLUS2. Conclusion: In conclusion, we have found PLR as measured by the NICOM to be a promising tool for the evaluation of SV responsiveness. It was feasible for use in the ED, and the data suggest that the PLR technique may be more reproducible than the fluid bolus technique for assessing volume responsiveness. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:217.e1 / 217.e5
页数:5
相关论文
共 22 条
  • [1] Fluid responsiveness predicted by noninvasive Bioreactance-based passive leg raise test
    Benomar, Brahim
    Ouattara, Alexandre
    Estagnasie, Philippe
    Brusset, Alain
    Squara, Pierre
    [J]. INTENSIVE CARE MEDICINE, 2010, 36 (11) : 1875 - 1881
  • [2] Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients
    Boulain, T
    Achard, JM
    Teboul, JL
    Richard, C
    Perrotin, D
    Ginies, G
    [J]. CHEST, 2002, 121 (04) : 1245 - 1252
  • [3] Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies
    Cavallaro, Fabio
    Sandroni, Claudio
    Marano, Cristina
    La Torre, Giuseppe
    Mannocci, Alice
    De Waure, Chiara
    Bello, Giuseppe
    Maviglia, Riccardo
    Antonelli, Massimo
    [J]. INTENSIVE CARE MEDICINE, 2010, 36 (09) : 1475 - 1483
  • [4] Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters
    Hadian, Mehrnaz
    Kim, Hyung Kook
    Severyn, Donald A.
    Pinsky, Michael R.
    [J]. CRITICAL CARE, 2010, 14 (06):
  • [5] Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance
    Keren, Hanan
    Burkhoff, Daniel
    Squara, Pierre
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2007, 293 (01): : H583 - H589
  • [6] Diagnosis of central hypovolemia by using passive leg raising
    Maizel, Julien
    Airapetian, Norair
    Lorne, Emmanuel
    Tribouilloy, Christophe
    Massy, Ziad
    Slama, Michel
    [J]. INTENSIVE CARE MEDICINE, 2007, 33 (07) : 1133 - 1138
  • [7] Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares
    Marik, Paul E.
    Baram, Michael
    Vahid, Bobbak
    [J]. CHEST, 2008, 134 (01) : 172 - 178
  • [8] The Use of Bioreactance and Carotid Doppler to Determine Volume Responsiveness and Blood Flow Redistribution Following Passive Leg Raising in Hemodynamically Unstable Patients
    Marik, Paul E.
    Levitov, Alex
    Young, Alisha
    Andrews, Lois
    [J]. CHEST, 2013, 143 (02) : 364 - 370
  • [9] Comparison between Flotrac-Vigileo and Bioreactance, a totally noninvasive method for cardiac output monitoring
    Marque, Sophie
    Cariou, Alain
    Chiche, Jean-Daniel
    Squara, Pierre
    [J]. CRITICAL CARE, 2009, 13 (03)
  • [10] Non-invasive assessment of fluid responsiveness by changes in partial end-tidal CO2 pressure during a passive leg-raising maneuver
    Monge Garcia, Manuel Ignacio
    Gil Cano, Anselmo
    Gracia Romero, Manuel
    Monterroso Pintado, Rocio
    Perez Madueno, Virginia
    Diaz Monrove, Juan Carlos
    [J]. ANNALS OF INTENSIVE CARE, 2012, 2 : 2 - 9