Detection of peri-implant bone defects using cone-beam computed tomography and digital periapical radiography with parallel and oblique projection

被引:14
作者
Saberi, Bardia Vadiati [1 ]
Khosravifard, Negar [2 ]
Ghandari, Farnaz [3 ]
Hadinezhad, Arash [3 ]
机构
[1] Guilan Univ Med Sci, Sch Dent, Dept Periodont, Dent Sci Res Ctr, Rasht, Iran
[2] Guilan Univ Med Sci, Sch Dent, Dept Maxillofacial Radiol, Dent Sci Res Ctr, Rasht, Iran
[3] Guilan Univ Med Sci, Sch Dent, Dept Maxillofacial Radiol, Rasht, Iran
关键词
Cone-Beam Computed Tomography; Radiography; Dental; Digital; Peri-Implantitis; DIAGNOSTIC-ACCURACY; DENTAL IMPLANTS; IN-VITRO; FENESTRATION;
D O I
10.5624/isd.2019.49.4.265
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare the diagnostic accuracy of cone-beam computed tomography (CBCT) with that of parallel (PPA) and oblique projected periapical (OPA) radiography for the detection of different types of peri-implant bone defects. Materials and Methods: Forty implants inserted into bovine rib blocks were used. Thirty had standardized bone defects (10 each of angular, fenestration, and dehiscence defects), and 10 were defect-free controls. CBCT, PPA, and OPA images of the samples were acquired. The images were evaluated twice by each of 2 blinded observers regarding the presence or absence and the type of the defects. The area under the receiver operating characteristic curve (AUC), sensitivity, and specificity were determined for each radiographic technique. The 3 modalities were compared using the Fisher exact and chi-square tests, with P<0.05 considered as statistical significance. Results: High inter-examiner reliability was observed for the 3 techniques. Angular defects were detected with high sensitivity and specificity by all 3 modalities. CBCT and OPA showed similar AUC and sensitivity in the detection of fenestration defects. In the identification of dehiscence defects, CBCT showed the highest sensitivity, followed by OPA and PPA, respectively. CBCT and OPA had a significantly greater ability than PPA to detect fenestration and dehiscence defects (P<0.05). Conclusion: The application of OPA radiography in addition to routine PPA imaging as a radiographic follow-up method for dental implantation greatly enhances the visualization of fenestration and dehiscence defects. CBCT properly depicted all defect types studied, but it involves a relatively high dose of radiation and cost.
引用
收藏
页码:265 / 272
页数:8
相关论文
共 22 条
  • [1] Comparison of intraoral radiography and cone-beam computed tomography for the detection of periodontal defects: an in vitro study
    Bagis, Nilsun
    Kolsuz, Mehmet Eray
    Kursun, Sebnem
    Orhan, Kaan
    [J]. BMC ORAL HEALTH, 2015, 15
  • [2] A comparison of cone beam computed tomography and conventional periapical radiography at detecting peri-implant bone defects
    Dave, Meetal
    Davies, Jonathan
    Wilson, Ron
    Palmer, Richard
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (06) : 671 - 678
  • [3] Detection of periimplant fenestration and dehiscence with the use of two scan modes and the smallest voxel sizes of a cone-beam computed tomography device
    de-Azevedo-Vaz, Sergio Lins
    Vasconcelos, Karla de Faria
    Neves, Frederico Sampaio
    Sousa Melo, Saulo Leonardo
    Flores Campos, Paulo Sergio
    Haiter-Neto, Francisco
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2013, 115 (01): : 121 - 127
  • [4] Association Between Peri-implant Bone Morphology and Marginal Bone Loss: A Retrospective Study on Implant-Supported Mandibular Overdentures
    Ding, Qian
    Zhang, Lei
    Geraets, Wil
    Wu, Wuqing
    Zhou, Yongsheng
    Wismeijer, Daniel
    Xie, Qiufei
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (01) : 147 - 155
  • [5] Diagnostic Accuracy of Three Cone Beam Computed Tomography Systems and Periapical Radiography for Detection of Fenestration Around Dental Implants
    Eskandarloo, Amir
    Saati, Samira
    Ardakani, Mahbubeh Purabdolahi
    Jamalpour, Mohamadreza
    Mezerji, Naser Mohammad Gholi
    Akheshteh, Vahid
    [J]. CONTEMPORARY CLINICAL DENTISTRY, 2018, 9 (03) : 376 - 381
  • [6] Accuracy of cone-beam computed tomography, dental magnetic resonance imaging, and intraoral radiography for detecting peri-implant bone defects at single zirconia implantsAn in vitro study
    Hilgenfeld, Tim
    Juerchott, Alexander
    Deisenhofer, Ulrich Karl
    Krisam, Johannes
    Rammelsberg, Peter
    Heiland, Sabine
    Bendszus, Martin
    Schwindling, Franz Sebastian
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (09) : 922 - 930
  • [7] Accuracy of CBCT images in the assessment of buccal marginal alveolar peri-implant defects: effect of field of view
    Kamburoglu, K.
    Murat, S.
    Kilic, C.
    Yuksel, S.
    Avsever, H.
    Farman, A.
    Scarfe, W. C.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2014, 43 (04)
  • [8] Khojastepour L, 2017, OPEN DENT J, V11, P367, DOI 10.2174/1874210601711010367
  • [9] Reconstructive Procedures for Treating Peri-implantitis: A Systematic Review
    Khoshkam, V.
    Chan, H. L.
    Lin, G. H.
    MacEachern, M. P.
    Monje, A.
    Suarez, F.
    Giannobile, W. V.
    Wang, H. L.
    [J]. JOURNAL OF DENTAL RESEARCH, 2013, 92 (S12) : 131S - 138S
  • [10] Detection of peri-implant bone defects with different radiographic techniques - a human cadaver study
    Kuehl, Sebastian
    Zuercher, Silvia
    Zitzmann, Nicola U.
    Filippi, Andreas
    Payer, Michael
    Dagassan-Berndt, Dorothea
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (05) : 529 - 534