Incidence of Distal Stent Graft Induced New Entry vs. Aortic Remodeling Associated With Frozen Elephant Trunk

被引:27
作者
Jubouri, Matti [1 ]
Kayali, Fatima [2 ]
Saha, Priyanshu [3 ]
Ansari, Daniyal M. [3 ]
Rezaei, Yousef [4 ]
Tan, Sven Z. C. P. [5 ]
Mousavizadeh, Mostafa [4 ]
Hosseini, Saeid [4 ]
Mohammed, Idhrees [6 ]
Bashir, Mohamad [7 ]
机构
[1] Univ York, Hull York Med Sch, York, England
[2] Univ Cent Lancashire, Sch Med, Preston, England
[3] St Georges Univ London, Sch Med, London, England
[4] Iran Univ, Heart Valve Dis Res Ctr, Rajaie Cardiovasc Med & Res Ctr, Med Sci, Tehran, Iran
[5] Queen Mary Univ, Barts & London Sch Med & Dent, London, England
[6] SIMS Hosp, Inst Cardiac & Aort Disorders ICAD, SRM Inst Med Sci, Chennai, India
[7] Velindre Univ NHS Trust, Vasc & Endovasc Surg, Hlth Educ & Improvement Wales HEIW, Cardiff, Wales
关键词
aortic dissection; aortic aneurysm; aortic surgery; frozen elephant trunk; total arch replacement; TOTAL ARCH REPLACEMENT; RESIDUAL TYPE-A; ENDOVASCULAR REPAIR; THORAFLEX HYBRID; MIDTERM OUTCOMES; DISSECTION; SURGERY; PROSTHESIS; ANEURYSM; IMPACT;
D O I
10.3389/fcvm.2022.875078
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundThe introduction of the frozen elephant trunk (FET) technique for total arch replacement (TAR) has revolutionized the field of aortivascular surgery by allowing hybrid repair of complex aortic pathologies in a single step through combining an open surgical approach with an endovascular one. FET has been associated with favorable aortic remodeling, however, its is also associated with development of distal stent graft induced new entry (dSINE) tears postoperatively. The rate of aortic remodeling and the incidence of dSINE have been linked together, in addition, there seems to be a relationship between these two variables and FET insetion length as well as graft size. AimsThe scope of this review is to highlight the rate of aortic remodeling as well the incidence of dSINE associated with different FET devices available commercially. This review also aimed to investigate the relationship between aortic remodeling, dSINE, FET insertion length and FET graft size. MethodsWe conducted a comprehensive literature search using multiple electronic databases including PubMed, Ovid, Scopus and Embase in order to collate all research evidence on the above mentioned variables. ResultsThoraflex (TM) Hybrid Plexus seems to yield optimum aortic remodeling by promoting maximum false thrombosis as well true lumen expansion. Thoraflex Hybrid (TM) is also associated with the lowest incidence of dSINE post-FET relative to the other FET devices on the market. Aortic remodeling and dSINE do influence each other and are both linked with FET graft length and size. ConclusionThe FET technique for TAR shows excellent aortic remodeling but is associated with a considerable risk of dSINE development. However, Thoraflex (TM) Hybrid has demonstrated itself to be the superior FET device on the aortic arch prostheses market. Since aortic remodeling, dSINE, FET insertion length and stent graft size are all interconnect, the choice of FET device length and size must be made with great care for optimum results.
引用
收藏
页数:11
相关论文
共 52 条
[1]   Early and mid-term results of frozen elephant trunk procedure for acute type A aortic dissection [J].
Akbulut, Mustafa ;
Ak, Adnan ;
Arslan, Ozgur ;
Cekmecelioglu, Davut ;
Tas, Serpil ;
Donmez, Arzu Antal ;
Sismanoglu, Mesut ;
Tuncer, Mehmet Altug .
TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 27 (02) :135-141
[2]   Multicentre experience with two frozen elephant trunk prostheses in the treatment of acute aortic dissection [J].
Berger, Tim ;
Weiss, Gabriel ;
Voetsch, Andreas ;
Arnold, Zsuzsanna ;
Kreibich, Maximilian ;
Rylski, Bartosz ;
Krombholz-Reindl, Philipp ;
Winkler, Andreas ;
Mach, Markus ;
Geisler, Daniela ;
Seitelberger, Rainald ;
Siepe, Mathias ;
Beyersdorf, Friedhelm ;
Grabenwoeger, Martin ;
Czerny, Martin ;
Gottardi, Roman .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 56 (03) :572-578
[3]   True-lumen and false-lumen diameter changes in the downstream aorta after frozen elephant trunk implantation [J].
Berger, Tim ;
Kreibich, Maximilian ;
Morlock, Julia ;
Kondov, Stoyan ;
Scheumann, Johannes ;
Kari, Fabian A. ;
Rylski, Bartosz ;
Siepe, Matthias ;
Beyersdorf, Friedhelm ;
Czerny, Martin .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 54 (02) :375-381
[4]   Risk factors for distal stent graft-induced new entry tear after endovascular repair of thoracic aortic dissection [J].
Canaud, Ludovic ;
Gandet, Thomas ;
Sfeir, Julien ;
Ozdemir, Baris Ata ;
Solovei, Laurence ;
Alric, Pierre .
JOURNAL OF VASCULAR SURGERY, 2019, 69 (05) :1610-1614
[5]  
Charchyan E R, 2020, Khirurgiia (Mosk), P28, DOI 10.17116/hirurgia202009128
[6]   Factors Affecting Optimal Aortic Remodeling After Thoracic Endovascular Aortic Repair of Type B (IIIb) Aortic Dissection [J].
Chen, I-Ming ;
Chen, Po-Lin ;
Huang, Chun-Yang ;
Weng, Shih-Hsien ;
Chen, Wei-Yuan ;
Shih, Chun-Che .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2017, 40 (05) :671-681
[7]   Total arch repair with open triple-branched stent graft placement for acute type A aortic dissection: Experience with 122 patients [J].
Chen, Liang-Wan ;
Lu, Lin ;
Dai, Xiao-Fu ;
Wu, Xi-Jie ;
Zhang, Gui-Can ;
Yang, Guo-Feng ;
Dong, Yi .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 148 (02) :521-528
[8]   Safety and pitfalls in frozen elephant trunk implantation [J].
Damberg, Anneke ;
Schaelte, Gereon ;
Autschbach, Ruediger ;
Hoffman, Andras .
ANNALS OF CARDIOTHORACIC SURGERY, 2013, 2 (05) :669-676
[9]   Frozen elephant trunk surgery in acute aortic dissection [J].
Di Bartolomeo, Roberto ;
Pantaleo, Antonio ;
Berretta, Paolo ;
Murana, Giacomo ;
Castrovinci, Sebastiano ;
Cefarelli, Mariano ;
Folesani, Gianluca ;
Di Eusanio, Marco .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 149 (02) :S105-S109
[10]  
Di Marco L., 2020, Vessel Plus, V4, P32, DOI [10.20517/2574-1209.2020.23, DOI 10.20517/2574-1209.2020.23]