Enzyme-linked immunosorbent assay for ondansetron captured from airborne samples

被引:1
作者
Hreczuk-Hirst, D [1 ]
Rowell, FJ
Reeve, RN
Cumming, RH
Guest, I
机构
[1] Univ Sunderland, Sch Hlth Sci, NE Biotechnol Ctr, Sunderland SR 3SD, England
[2] Univ Teesside, Sch Sci & Technol, NE Biotechnol Ctr, Middlesbrough TS1 3BA, Cleveland, England
[3] GlaxoWellcome Operat, Occupat Hlth, Ware SG12 0DJ, Herts, England
关键词
ondansetron; enzyme linked immunosorbent assay; airborne workplace monitoring; health and safety;
D O I
10.1039/a708204e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and relatively rapid enzyme-linked immunosorbant assay method for the anti-emetic drug ondansetron has been developed for its quantitation in solution. This has been optimised for use with samples that have been obtained following extraction of filters after the drug's capture from air samples in the workplace. The assay has the sample throughput (40 duplicate samples in 3 h), specificity, sensitivity (LOD of 10.5 ng drug ml(-1)) and precision (RSD < 11%) necessary for its use in determining airborne concentrations of ondansetron in such samples as part of an occupational health and hygiene monitoring programme.
引用
收藏
页码:1121 / 1126
页数:6
相关论文
共 14 条
  • [1] THE CHEMISTRY OF BACTERIA .5. SOME ACYLINDOLES
    BALLANTINE, JA
    BARRETT, CB
    BEER, RJS
    BOGGIANO, BG
    EARDLEY, S
    JENNINGS, BE
    ROBERTSON, A
    [J]. JOURNAL OF THE CHEMICAL SOCIETY, 1957, (MAY): : 2227 - 2231
  • [2] BHIDE GV, 1957, CHEM IND-LONDON, P363
  • [3] THE CHEMISTRY OF THE CARBAZOLES - 1-2-3-4-TETRAHYDRO-4-KETOCARBAZOLES
    CLEMO, GR
    FELTON, DGI
    [J]. JOURNAL OF THE CHEMICAL SOCIETY, 1951, (MAR): : 700 - 703
  • [4] DETERMINATION OF ONDANSETRON IN PLASMA AND ITS PHARMACOKINETICS IN THE YOUNG AND ELDERLY
    COLTHUP, PV
    FELGATE, CC
    PALMER, JL
    SCULLY, NL
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 1991, 80 (09) : 868 - 871
  • [5] ENVIRONMENTAL-ANALYSIS IN THE WORKPLACE - DEVELOPMENT OF AIRBORNE MONITORING SYSTEMS FOR POTENTIALLY HARMFUL PHARMACEUTICALS - AN IMPROVED RAPID ELISA FOR CEFTAZIDIME
    CUMMING, R
    FARRELL, C
    NITESCU, I
    ROWELL, FJ
    TANG, LX
    [J]. ANALYTICA CHIMICA ACTA, 1995, 311 (03) : 377 - 382
  • [6] REACTION OF CYCLOALKANE-1,3-DIONES WITH HYDRAZINES .1.
    EISTERT, B
    KILPPER, G
    GORING, J
    [J]. CHEMISCHE BERICHTE-RECUEIL, 1969, 102 (04): : 1379 - &
  • [7] *GLAX OP, SUBST INF SHEET OND
  • [8] LIU J, 1997, CHROMATOGR B, V694, P179
  • [9] ENVIRONMENTAL-ANALYSIS IN THE WORKPLACE - DEVELOPMENT OF A RAPID, SENSITIVE ELISA FOR MONITORING AIRBORNE ALCALASE
    ROWELL, FJ
    CUMMING, RH
    NITESCU, I
    [J]. ANALYTICA CHIMICA ACTA, 1995, 316 (02) : 247 - 252
  • [10] Direct on-filter immunoassay of some β-lactam antibiotics for rapid analysis of drug captured from the workplace atmosphere
    Rowell, FJ
    Miao, ZF
    Reeves, RN
    Cumming, RH
    [J]. ANALYST, 1997, 122 (12) : 1505 - 1508