Surface plasmon resonance:: instrumental resolution using photo diode arrays

被引:77
作者
Johansen, K [1 ]
Stålberg, R
Lundström, I
Liedberg, B
机构
[1] Linkoping Univ, Dept Phys & Measurement Technol, Appl Phys Lab, S-58183 Linkoping, Sweden
[2] Hogskolen & Telemark, N-3800 Bo, Norway
关键词
surface plasmon resonance; resolution; analogue-to-digital converter; photo diode arrays;
D O I
10.1088/0957-0233/11/11/313
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Surface plasmon resonance (SPR) sensors are used to study biomolecular interactions. We have performed a theoretical analysis of a SPR instrument using a convergent beam, a linear detector with various numbers of pixels and various analogue-to-digital converters (ADCs) with a corresponding resolution ranging from 8 to 16 bits. Studies of small molecules at low concentrations or with low affinities are limited by the instrumental set-up, e.g. by the resolution, linearity and noise. The amplitudes of these parameters are highly dependent on the detector, ADC and dip-finding algorithm used. We have studied several dip-finding algorithms, e.g. intensity measurements, second- and third-order polynomial fits and centroid algorithms. Each algorithm used with the ADC and the detector has a resolution associated with it. Some algorithms also have an intrinsic algorithm error that is dependent on the number of pixels and the shape of the dip. A weighted centroid algorithm that has an excellent overall performance is described. If an accuracy of 10(-6) refractive index units (RIU) is satisfactory, a 12-bit ADC and a 64-pixel detector are appropriate. Theoretically, by using a 16-bit ADC and a 1024-pixel detector, a resolution of better than 10(-9) RIU is obtainable.
引用
收藏
页码:1630 / 1638
页数:9
相关论文
共 29 条
[1]   Optimal linear data analysis for surface plasmon resonance biosensors [J].
Chinowsky, TM ;
Jung, LS ;
Yee, SS .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 54 (1-2) :89-97
[2]   REAL-TIME BIOMOLECULAR INTERACTION ANALYSIS USING THE RESONANT MIRROR SENSOR [J].
GODDARD, NJ ;
POLLARDKNIGHT, D ;
MAULE, CH .
ANALYST, 1994, 119 (04) :583-588
[3]  
GRAY RM, 1993, IEEE T INFORM THEORY, V39, P805, DOI 10.1109/18.256489
[4]  
Holman J.P., 1997, HEAT TRANSFER
[5]  
JOHANSEN K, 2000, IN PRESS BIOSENSORS, V15
[6]   Performance comparison between high and low resolution spectrophotometers used in a white light surface plasmon resonance sensor [J].
Johnston, KS ;
Booksh, KS ;
Chinowsky, TM ;
Yee, SS .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 54 (1-2) :80-88
[7]   SURFACE-PLASMON RESONANCE DETECTION AND MULTISPOT SENSING FOR DIRECT MONITORING OF INTERACTIONS INVOLVING LOW-MOLECULAR-WEIGHT ANALYTES AND FOR DETERMINATION OF LOW AFFINITIES [J].
KARLSSON, R ;
STAHLBERG, R .
ANALYTICAL BIOCHEMISTRY, 1995, 228 (02) :274-280
[8]   Sensitivity and detection limit of concentration and adsorption measurements by laser-induced surface-plasmon resonance [J].
Kolomenskii, AA ;
Gershon, PD ;
Schuessler, HA .
APPLIED OPTICS, 1997, 36 (25) :6539-6547
[9]   SURFACE-PLASMON RESONANCE IMMUNOSENSORS - SENSITIVITY CONSIDERATIONS [J].
KOOYMAN, RPH ;
KOLKMAN, H ;
VANGENT, J ;
GREVE, J .
ANALYTICA CHIMICA ACTA, 1988, 213 (1-2) :35-45
[10]   DETERMINATION OF OPTICAL CONSTANTS OF METALS BY EXCITATION OF SURFACE PLASMONS [J].
KRETSCHM.E .
ZEITSCHRIFT FUR PHYSIK, 1971, 241 (04) :313-&