Energy performance assessment of HVAC commissioning using long-term monitoring data: A case study of the newly built office building in South Korea

被引:29
作者
Kim, Dong-Bae [1 ]
Kim, Daeung Danny [2 ]
Kim, Taeyeon [3 ]
机构
[1] EAN Technol, Seoul, South Korea
[2] KFUPM, Architectural Engn Dept, Dhahran, Saudi Arabia
[3] Yonsei Univ, Dept Architectural Engn, 50 Yonsei Ro, Seoul 120749, South Korea
基金
新加坡国家研究基金会;
关键词
HVAC commissioning; Office building; Long-term monitoring; Energy consumption; Cost-effectiveness; OPTIMIZATION SYSTEM; PREDICTIVE CONTROL; CONSUMPTION; EFFICIENCY; MODELS; IMPACT;
D O I
10.1016/j.enbuild.2019.109465
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Facing severe climate change, the rapid increase in building energy consumption has become the major challenge and much attention has been paid to reduce energy use by buildings and their components. Among factors relates the building components, HVAC (Heating, Ventilation, and Air-Conditioning) systems, and their operation have accounted for the largest share of total building energy consumption. The present study applied HVAC commissioning to a newly constructed office building in South Korea to investigate the impact on energy consumption. The energy demands for the case building were simulated by using data collected by BEMS and BAS and IPMVP Option D is used to calibrate the conditions of the energy simulation. Utilizing the calibrated energy model, several cases were created and examined to find out the energy effectiveness of the HVAC commissioning. Moreover, the cost-effectiveness of the case building with HVAC commissioning was analyzed. Implementing HVAC commissioning, about 2-6% of the total energy was reduced as per the occupancy rates and the payback period was also calculated. The obtained results of the present study showed the effectiveness of HVAC commissioning and the study can provide information for the development of HVAC commissioning for commercial buildings in Korea. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 38 条
[1]  
American Society of Heating, 2002, REFR AIR COND ENG AS
[2]   Using multiple regression analysis to develop energy consumption indicators for commercial buildings in the US [J].
Amiri, Shideh Shams ;
Mottahedi, Mohammad ;
Asadi, Somayeh .
ENERGY AND BUILDINGS, 2015, 109 :209-216
[3]  
[Anonymous], M V GUID MEAS VER PE
[4]  
[Anonymous], ANN EN CONS 2017
[5]  
[Anonymous], CAT EN TECHN TRANSF
[6]   Non-intrusive occupancy monitoring for energy conservation in commercial buildings [J].
Ardakanian, Omid ;
Bhattacharya, Arka ;
Culler, David .
ENERGY AND BUILDINGS, 2018, 179 :311-323
[7]   Mapping failures in energy and environmental performance of buildings [J].
Borgstein, E. H. ;
Lamberts, R. ;
Hensen, J. L. M. .
ENERGY AND BUILDINGS, 2018, 158 :476-485
[8]   Development and testing of an Automated Building Commissioning Analysis Tool (ABCAT) [J].
Bynum, John D. ;
Claridge, David E. ;
Curtin, Jonathan M. .
ENERGY AND BUILDINGS, 2012, 55 :607-617
[9]   Data analytics for occupancy pattern learning to reduce the energy consumption of HVAC systems in office buildings [J].
Capozzoli, Alfonso ;
Piscitelli, Marco Savino ;
Gorrino, Alice ;
Ballarini, Ilaria ;
Corrado, Vincenzo .
SUSTAINABLE CITIES AND SOCIETY, 2017, 35 :191-208
[10]   PCA-based method of soft fault detection and identification for the ongoing commissioning of chillers [J].
Cotrufo, Nunzio ;
Zmeureanu, Radu .