Bone mineral density of the femoral neck in resurfacing hip arthroplasty Precision of DXA biased by region of interest and rotation of the hip

被引:12
作者
Penny, Jeannette Ostergaard [1 ,3 ,4 ]
Ovesen, Ole [1 ,3 ]
Brixen, Kim [2 ,3 ]
Varmarken, Jens-Erik [4 ]
Overgaard, Soren [1 ,3 ]
机构
[1] Odense Univ Hosp, Dept Orthoped Surg, DK-5000 Odense, Denmark
[2] Odense Univ Hosp, Dept Endocrinol, DK-5000 Odense, Denmark
[3] Univ So Denmark, Inst Clin, Odense, Denmark
[4] Naestved Hosp, Dept Orthoped Surg, Naestved, Denmark
关键词
X-RAY ABSORPTIOMETRY; DEXA MEASUREMENT; PROXIMAL FEMUR; WEAR DEBRIS; REPLACEMENT; REPRODUCIBILITY; PRESERVATION; DENSITOMETRY; ACCURACY; HEAD;
D O I
10.3109/17453674.2010.480935
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and purpose Resurfacing total hip arthroplasty (RTHA) may preserve the femoral neck bone stock postoperatively. Bone mineral density (BMD) may be affected by the hip position, which might bias longitudinal studies. We investigated the dependency of BMD precision on type of ROI and hip position. Method We DXA-scanned the femoral neck of 15 resurfacing patients twice with the hip in 3 different rotations: 15 degrees internal, neutral, and 15 degrees external. For each position, BMD was analyzed with 3 surface area models. One model measured BMD in the total femoral neck, the second model divided the neck in two, and the third model had 6 divisions. Results When all hip positions were pooled, average coefficients of variation (CVs) of 3.1%, 3.6%, and 4.6% were found in the 1-, 2-, and 6-region models, respectively. The externally rotated hip position was less reproducible. When rotating in increments of 15 degrees or 30 degrees, the average CVs rose to 7.2%, 7.3%, and 12% in the 3 models. Rotation affected the precision most in the model that divided the neck in 6 subregions, predominantly in the lateral and distal regions. For larger-region models, some rotation could be allowed without compromising the precision. Interpretation If hip rotation is strictly controlled, DXA can reliably provide detailed topographical information about the BMD changes around an RTHA. As rotation strongly affects the precision of the BMD measurements in small regions, we suggest that a less detailed model should be used for analysis in studies where the leg position has not been firmly controlled.
引用
收藏
页码:318 / 323
页数:6
相关论文
共 29 条
  • [1] Metal-on-metal bearing in hip prosthesis generates 100-fold less wear debris than metal-on-polyethylene
    Anissian, HL
    Stark, A
    Gustafson, A
    Good, V
    Clarke, IC
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1999, 70 (06): : 578 - 582
  • [2] ACCURACY OF DEXA MEASUREMENT OF BONE-MINERAL DENSITY AFTER TOTAL HIP-ARTHROPLASTY
    COHEN, B
    RUSHTON, N
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (03): : 479 - 483
  • [3] FACTORS INFLUENCING SHORT-TERM PRECISION OF DUAL X-RAY BONE ABSORPTIOMETRY (DXA) OF SPINE AND FEMUR
    ENGELKE, K
    GLUER, CC
    GENANT, HK
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1995, 56 (01) : 19 - 25
  • [4] The accuracy and reproducibility of radiographic assessment of stress-shielding - A postmortem analysis
    Engh, CA
    McAuley, JP
    Sychterz, CJ
    Sacco, ME
    Engh, CA
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (10) : 1414 - 1420
  • [5] Presidential guest lecture - Tribology of alternative beatings
    Fisher, John
    Jin, Zhongmin
    Tipper, Joanne
    Stone, Martin
    Ingham, Eileen
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (453) : 25 - 34
  • [6] GEHRCHEN PM, 1999, THESIS
  • [7] ACCURATE ASSESSMENT OF PRECISION ERRORS - HOW TO MEASURE THE REPRODUCIBILITY OF BONE DENSITOMETRY TECHNIQUES
    GLUER, CC
    BLAKE, G
    LU, Y
    BLUNT, BA
    JERGAS, M
    GENANT, HK
    [J]. OSTEOPOROSIS INTERNATIONAL, 1995, 5 (04) : 262 - 270
  • [8] EFFECT OF FEMORAL ROTATION ON BONE-MINERAL DENSITY-MEASUREMENTS WITH DUAL-ENERGY X-RAY ABSORPTIOMETRY
    GOH, JCH
    LOW, SL
    BOSE, K
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1995, 57 (05) : 340 - 343
  • [9] Bone remodelling inside a cemented resurfaced femoral head
    Gupta, Sanjay
    New, Andrew M. R.
    Taylor, Mark
    [J]. CLINICAL BIOMECHANICS, 2006, 21 (06) : 594 - 602
  • [10] High wear rates and extensive osteolysis in 3 types of uncemented total hip arthroplasty - A review of the PCA, the Harris Galante and the profile/tri-lock plus arthroplasties with a minimum of 12 years median follow-up in 96 hips
    Hallan, Geir
    Lie, Stein A.
    Havelin, Leif I.
    [J]. ACTA ORTHOPAEDICA, 2006, 77 (04) : 575 - 584