Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) with Standard Reference Line for the Analysis of Stainless Steel

被引:23
作者
Fu, Hongbo [1 ,2 ,3 ]
Dong, Fengzhong [1 ,2 ,3 ]
Wang, Huadong [1 ,2 ]
Jia, Junwei [1 ,2 ]
Ni, Zhibo [1 ]
机构
[1] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Anhui Prov Key Lab Photon Devices & Mat, Hefei 230031, Anhui, Peoples R China
[2] Univ Sci & Technol China, Sch Environm Sci & Optoelect Technol, Hefei, Anhui, Peoples R China
[3] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Key Lab Environm Opt & Technol, Hefei, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
Calibration-free laser-induced breakdown spectroscopy; CF-LIBS; self-absorption; Saha-Boltzmann; Stark broadening; standard reference line; QUANTITATIVE ELEMENTAL ANALYSIS; INDUCED PLASMA SPECTROSCOPY; SELF-ABSORPTION; SPECTRAL-LINES; TEMPERATURE; ACCURACY; ALUMINUM;
D O I
10.1177/0003702817699410
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this work, calibration-free laser-induced breakdown spectroscopy (CF-LIBS) is used to analyze a certified stainless steel sample. Due to self-absorption of the spectral lines from the major element Fe and the sparse lines of trace elements, it is usually not easy to construct the Boltzmann plots of all species. A standard reference line method is proposed here to solve this difficulty under the assumption of local thermodynamic equilibrium so that the same temperature value for all elements present into the plasma can be considered. Based on the concentration and rich spectral lines of Fe, the Stark broadening of Fe(I) 381.584nm and Saha-Boltzmann plots of this element are used to calculate the electron density and the plasma temperature, respectively. In order to determine the plasma temperature accurately, which is seriously affected by self-absorption, a pre-selection procedure for eliminating those spectral lines with strong self-absorption is employed. Then, one spectral line of each element is selected to calculate its corresponding concentration. The results from the standard reference lines with and without self-absorption of Fe are compared. This method allows us to measure trace element content and effectively avoid the adverse effects due to self-absorption.
引用
收藏
页码:1982 / 1989
页数:8
相关论文
共 35 条
[1]   Curves of growth of spectral lines emitted by a laser-induced plasma:: influence of the temporal evolution and spatial inhomogeneity of the plasma [J].
Aguilera, JA ;
Bengoechea, J ;
Aragón, C .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (2-3) :221-237
[2]   Spectral line selection for time-resolved investigations of laser-induced plasmas by an iterative Boltzmann plot method [J].
Aydin, Uemit ;
Roth, Peter ;
Gehlen, Christoph Dominic ;
Noll, Reinhard .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (10) :1060-1065
[3]   Spectral standard-free laser microanalysis of gold alloys [J].
Bel'kov M.V. ;
Burakov V.S. ;
Kiris V.V. ;
Kozhukh N.M. ;
Raikov S.N. .
Journal of Applied Spectroscopy, 2005, 72 (3) :376-381
[4]   Characterization of azurite and lazurite based pigments by laser induced breakdown spectroscopy and micro-Raman spectroscopy [J].
Bicchieri, M ;
Nardone, M ;
Russo, PA ;
Sodo, A ;
Corsi, M ;
Cristoforetti, G ;
Palleschi, V ;
Salvetti, A ;
Tognoni, E .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (06) :915-922
[5]   Self-calibrated quantitative elemental analysis by laser-induced plasma spectroscopy: application to pigment analysis [J].
Borgia, Ilaria ;
Burgio, Lucia M. F. ;
Corsi, Michela ;
Fantoni, Roberta ;
Palleschi, Vincenzo ;
Salvetti, Azenio ;
Squarcialupi, Maria Cristina ;
Tognoni, Elisabetta .
JOURNAL OF CULTURAL HERITAGE, 2000, 1 :S281-S286
[6]   A procedure for correcting self-absorption in calibration free-laser induced breakdown spectroscopy [J].
Bulajic, D ;
Corsi, M ;
Cristoforetti, G ;
Legnaioli, S ;
Palleschi, V ;
Salvetti, A ;
Tognoni, E .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (02) :339-353
[7]   One-point calibration for calibration-free laser-induced breakdown spectroscopy quantitative analysis [J].
Cavalcanti, G. H. ;
Teixeira, D. V. ;
Legnaioli, S. ;
Lorenzetti, G. ;
Pardini, L. ;
Palleschi, V. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2013, 87 :51-56
[8]   Quantitative Analysis of Slag by Calibration-Free Laser-Induced Breakdown Spectroscopy [J].
Chen Xing-long ;
Dong Feng-zhong ;
Wang Qi ;
Yu Rong-hua ;
Liang Yun-xian ;
Wang Jing-ge ;
Yang Yang ;
Ni Zhi-bo ;
Xu Ming-ming ;
Wu Bian .
SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31 (12) :3289-3293
[9]   New procedure for quantitative elemental analysis by laser-induced plasma spectroscopy [J].
Ciucci, A ;
Corsi, M ;
Palleschi, V ;
Rastelli, S ;
Salvetti, A ;
Tognoni, E .
APPLIED SPECTROSCOPY, 1999, 53 (08) :960-964
[10]   Investigation of LIBS feasibility for in situ planetary exploration:: An analysis on Martian rock analogues [J].
Colao, F ;
Fantoni, R ;
Lazic, V ;
Paolini, A ;
Fabbri, F ;
Ori, GG ;
Marinangeli, L ;
Baliva, A .
PLANETARY AND SPACE SCIENCE, 2004, 52 (1-3) :117-123