摘要
Purpose: To describe the details and experience of implementing a MR-only workflow in the clinic for simulation and planning of prostate cancer patients. Methods: Forty-eight prostate cancer patients from June 2016 -Dec 2016 receiving external beam radiotherapy were scheduled to undergo MR-only simulation. MR images were acquired for contouring (T2w axial, coronal, sagittal), synthetic-CT generation (3D FFE-based) and fiducial identification (3D bFFE-based). The total acquisition time was 25 min. Syn-CT was generated at the console using commercial software called MRCAT. As part of acceptance testing of the MRCAT package, external laser positioning system QA (< 2 mm) and geometric fidelity QA (< 2 mm within 50 cm LR and 30 cm AP) were performed and baseline values were set. Our current combined CT + MR simulation process was modified to accommodate a MRCAT-based MR-only simulation workflow. An automated step-by-step process using a MIMTM workflow was created for contouring on the MR images. Patient setup for treatment was achieved by matching the MRCAT DRRs with the orthogonal KV radiographs based on either fiducial ROIs or bones. 3-D CBCTs were acquired and compared with the MR/syn-CT to assess the rectum and bladder filling compared to simulation conditions. Results: Forty-two patients successfully underwent MR-only simulation and met all of our institutional dosimetric objectives that were developed based on a CT + MR-based workflow. The remaining six patients either had a hip prosthesis or their large body size fell outside of the geometric fidelity QA criteria and thus they were not candidates for MR-only simulation. A total time saving of similar to 15 min was achieved with MR-based simulation as compared to CT + MR-based simulation. An automated and organized MIM workflow made contouring on MR much easier, quicker and more accurate compared with combined CT + MR images because the temporal variations in normal structure was minimal. 2D and 3D treatment setup localization based on bones/fiducials using a MRCAT reference image was successfully achieved for all cases. Conclusions: MR-only simulation and planning with equivalent or superior target delineation, planning and treatment setup localization accuracy is feasible in a clinical setting. Future work will focus on implementing a robust 3D isotropic acquisition for contouring.
引用
收藏
页数:12
相关论文
共 50 条
[41]   Does dose calculation algorithm affect the dosimetric accuracy of synthetic CT for MR-only radiotherapy planning in brain tumors? [J].
Lui, Jeffrey C. F. ;
Lee, Francis K. H. ;
Law, C. C. ;
Chow, James C. H. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025, 26 (05)
[42]   Synthetic digital reconstructed radiographs for MR-only robotic stereotactic radiation therapy: A proof of concept [J].
Szalkowski, Gregory ;
Nie, Dong ;
Zhu, Tong ;
Yap, Pew-Thian ;
Lian, Jun .
COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 138 (138)
[43]   Deep learning-based synthetic CT generation for MR-only radiotherapy of prostate cancer patients with 0.35T MRI linear accelerator [J].
Farjam, Reza ;
Nagar, Himanshu ;
Kathy Zhou, Xi ;
Ouellette, David ;
Chiara Formenti, Silvia ;
DeWyngaert, J. Keith .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (08) :93-104
[44]   A high-performance method of deep learning for prostate MR-only radiotherapy planning using an optimized Pix2Pix architecture [J].
Tahri, S. ;
Barateau, A. ;
Cadin, C. ;
Chourak, H. ;
Ribault, S. ;
Nozahic, F. ;
Acosta, O. ;
Dowling, J. A. ;
Greer, P. B. ;
Largent, A. ;
Lafond, C. ;
De Crevoisier, R. ;
Nunes, J. C. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 103 :108-118
[45]   MR-only workflow in the brain: a DL algorithm to generate synthetic CT starting from 0.35T MRI [J].
Vellini, Luca ;
Lenkowicz, Jacopo ;
Votta, Claudio ;
Menna, Sebastiano ;
Quaranta, FlavioVincenzo ;
Pilloni, Elisa ;
Aquilano, Michele ;
D'Aviero, Andrea ;
Iezzi, Martina ;
Preziosi, Francesco ;
Re, Alessia ;
Boschetti, Althea ;
Piccari, Danila ;
Piras, Antonio ;
Di Dio, Carmela ;
Catucci, Francesco ;
Mattiucci, Gian Carlo ;
Cusumano, Davide .
RADIOTHERAPY AND ONCOLOGY, 2024, 194 :S3872-S3873
[46]   MR-PROTECT: Clinical feasibility of a prostate MRI-only radiotherapy treatment workflow and investigation of acceptance criteria [J].
Emilia Persson ;
Christian Jamtheim Gustafsson ;
Petra Ambolt ;
Silke Engelholm ;
Sofie Ceberg ;
Sven Bäck ;
Lars E. Olsson ;
Adalsteinn Gunnlaugsson .
Radiation Oncology, 15
[47]   Towards MR-Only Radiotherapy Treatment Planning: Synthetic CT Generation Using Multi-view Deep Convolutional Neural Networks [J].
Zhao, Yu ;
Liao, Shu ;
Guo, Yimo ;
Zhao, Liang ;
Yan, Zhennan ;
Hong, Sungmin ;
Hermosillo, Gerardo ;
Liu, Tianming ;
Zhou, Xiang Sean ;
Zhan, Yiqiang .
MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2018, PT I, 2018, 11070 :286-294
[48]   MR-OPERA: A Multicenter/Multivendor Validation of Magnetic Resonance Imaginge-Only Prostate Treatment Planning Using Synthetic Computed Tomography Images [J].
Persson, Emilia ;
Gustafsson, Christian ;
Nordstrom, Fredrik ;
Sohlin, Maja ;
Gunnlaugsson, Adalsteinn ;
Petruson, Karin ;
Rintela, Niina ;
Hed, Kristoffer ;
Blomqvist, Lennart ;
Zackrisson, Bjorn ;
Nyholm, Tufve ;
Olsson, Lars E. ;
Siversson, Carl ;
Jonsson, Joakim .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (03) :692-700
[49]   A body mass index-based method for "MR-only" abdominal MR-guided adaptive radiotherapy [J].
Rippke, Carolin ;
Renkamp, C. Katharina ;
Stahl-Arnsberger, Christiane ;
Miltner, Annette ;
Buchele, Carolin ;
Hoerner-Rieber, Juliane ;
Ristau, Jonas ;
Alber, Markus ;
Debus, Juergen ;
Klueter, Sebastian .
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2024, 34 (03) :456-467
[50]   SARU: A self-attention ResUNet to generate synthetic CT images for MR-only BNCT treatment planning [J].
Zhao, Sheng ;
Geng, Changran ;
Guo, Chang ;
Tian, Feng ;
Tang, Xiaobin .
MEDICAL PHYSICS, 2023, 50 (01) :117-127