Clinical workflow for MR-only simulation and planning in prostate

被引:82
作者
Tyagi, Neelam [1 ]
Fontenla, Sandra [1 ]
Zelefsky, Michael [2 ]
Chong-Ton, Marcia [2 ]
Ostergren, Kyle [3 ]
Shah, Niral [1 ]
Warner, Lizette [4 ]
Kadbi, Mo [4 ]
Mechalakos, Jim [1 ]
Hunt, Margie [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, 1275 York Ave, New York, NY 10065 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Radiat Oncol, 1275 York Ave, New York, NY 10065 USA
[3] MIM Software Inc, Cleveland, OH 44122 USA
[4] Philips Healthcare, 595 Milner Rd, Cleveland, OH 44143 USA
来源
RADIATION ONCOLOGY | 2017年 / 12卷
关键词
Synthetic CT; MRCAT; Clinical workflow; Prostate cancer; RADIATION-THERAPY; CANCER; CT; MULTIOBSERVER; RADIOTHERAPY; ACCURACY; STANDARD; IMAGES; SPACER;
D O I
10.1186/s13014-017-0854-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To describe the details and experience of implementing a MR-only workflow in the clinic for simulation and planning of prostate cancer patients. Methods: Forty-eight prostate cancer patients from June 2016 -Dec 2016 receiving external beam radiotherapy were scheduled to undergo MR-only simulation. MR images were acquired for contouring (T2w axial, coronal, sagittal), synthetic-CT generation (3D FFE-based) and fiducial identification (3D bFFE-based). The total acquisition time was 25 min. Syn-CT was generated at the console using commercial software called MRCAT. As part of acceptance testing of the MRCAT package, external laser positioning system QA (< 2 mm) and geometric fidelity QA (< 2 mm within 50 cm LR and 30 cm AP) were performed and baseline values were set. Our current combined CT + MR simulation process was modified to accommodate a MRCAT-based MR-only simulation workflow. An automated step-by-step process using a MIMTM workflow was created for contouring on the MR images. Patient setup for treatment was achieved by matching the MRCAT DRRs with the orthogonal KV radiographs based on either fiducial ROIs or bones. 3-D CBCTs were acquired and compared with the MR/syn-CT to assess the rectum and bladder filling compared to simulation conditions. Results: Forty-two patients successfully underwent MR-only simulation and met all of our institutional dosimetric objectives that were developed based on a CT + MR-based workflow. The remaining six patients either had a hip prosthesis or their large body size fell outside of the geometric fidelity QA criteria and thus they were not candidates for MR-only simulation. A total time saving of similar to 15 min was achieved with MR-based simulation as compared to CT + MR-based simulation. An automated and organized MIM workflow made contouring on MR much easier, quicker and more accurate compared with combined CT + MR images because the temporal variations in normal structure was minimal. 2D and 3D treatment setup localization based on bones/fiducials using a MRCAT reference image was successfully achieved for all cases. Conclusions: MR-only simulation and planning with equivalent or superior target delineation, planning and treatment setup localization accuracy is feasible in a clinical setting. Future work will focus on implementing a robust 3D isotropic acquisition for contouring.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Dosimetric evaluation of MR-derived synthetic-CTs for MR-only proton treatment planning
    Nunez, David Aramburu
    Fontenla, Sandra
    Rydquist, Lauren
    Del Rosario, Gabriely
    Han, Zhiqiang
    Chen, Chin-Cheng
    Mah, Dennis
    Tyagi, Neelam
    MEDICAL DOSIMETRY, 2020, 45 (03) : 264 - 270
  • [22] MR-PROTECT: Clinical feasibility of a prostate MRI-only radiotherapy treatment workflow and investigation of acceptance criteria
    Persson, Emilia
    Gustafsson, Christian Gustafsson
    Ambolt, Petra
    Engelholm, Silke
    Ceberg, Sofie
    Back, Sven
    Olsson, Lars E.
    Gunnlaugsson, Adalsteinn
    RADIATION ONCOLOGY, 2020, 15 (01)
  • [23] Magnetic Resonance Imaging only Workflow for Radiotherapy Simulation and Planning in Prostate Cancer
    Kerkmeijer, L. G. W.
    Maspero, M.
    Meijer, G. J.
    van Zyp, J. R. N. van der Voort
    de Boer, C. J.
    van den Berg, C. A. T.
    CLINICAL ONCOLOGY, 2018, 30 (11) : 692 - 701
  • [24] A Multi-center Prospective Study for Implementation of an MRI-Only Prostate Treatment Planning Workflow
    Greer, Peter
    Martin, Jarad
    Sidhom, Mark
    Hunter, Perry
    Pichler, Peter
    Choi, Jae Hyuk
    Best, Leah
    Smart, Joanne
    Young, Tony
    Jameson, Michael
    Afinidad, Tess
    Wratten, Chris
    Denham, James
    Holloway, Lois
    Sridharan, Swetha
    Rai, Robba
    Liney, Gary
    Raniga, Parnesh
    Dowling, Jason
    FRONTIERS IN ONCOLOGY, 2019, 9
  • [25] Verification imaging in prostate MR-only radiotherapy: Are fiducial markers necessary?
    Brooks-Pearson, R. L.
    Pearson, R. A.
    O'Connor, L.
    Skehan, K.
    Redding, D.
    Wilkins, E.
    Taylor, S.
    Wyatt, J. J.
    RADIOGRAPHY, 2025, 31 (01) : 333 - 340
  • [26] Investigating the generalisation of an atlas-based synthetic-CT algorithm to another centre and MR scanner for prostate MR-only radiotherapy
    Wyatt, Jonathan J.
    Dowling, Jason A.
    Kelly, Charles G.
    McKenna, Jill
    Johnstone, Emily
    Speight, Richard
    Henry, Ann
    Greer, Peter B.
    McCallum, Hazel M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (24) : N548 - N560
  • [27] CycleSeg: Simultaneous synthetic CT generation and unsupervised segmentation for MR-only radiotherapy treatment planning of prostate cancer
    Luu, Huan Minh
    Yoo, Gyu Sang
    Park, Won
    Park, Sung-Hong
    MEDICAL PHYSICS, 2024, 51 (06) : 4365 - 4379
  • [28] The benefit of MR-only radiotherapy treatment planning for anal and rectal cancers: A planning study
    Bird, David
    Nix, Michael G.
    McCallum, Hazel
    Teo, Mark
    Gilbert, Alexandra
    Casanova, Nathalie
    Cooper, Rachel
    Buckley, David L.
    Sebag-Montefiore, David
    Speight, Richard
    Al-Qaisieh, Bashar
    Henry, Ann M.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (11): : 41 - 53
  • [29] Brain and Head-and-Neck MRI in Immobilization Mask: A Practical Solution for MR-Only Radiotherapy
    Mandija, Stefano
    D'Agata, Federico
    Navest, Robin J. M.
    Sbrizzi, Alessandro
    Tijssen, Rob H. N.
    Philippens, Marielle E. P.
    Raaijmakers, Cornelis P. J.
    Seravalli, Enrica
    Verhoeff, Joost J. C.
    Lagendijk, Jan J. W.
    van den Berg, Cornelis A. T.
    FRONTIERS IN ONCOLOGY, 2019, 9
  • [30] A combined automatic MR OAR contouring and synthetic CT solution for prostate MR-only radiotherapy
    Wyatt, Jonathan J.
    Kaushik, Sandeep
    Cozzini, Cristina
    Kolozsvari, Bernadett
    Deak-Karancsi, Borbala
    Pearson, Rachel A.
    Petit, Steven
    Capala, Marta
    Hernandez-Tamames, Juan A.
    Hideghety, Katalin
    Maxwell, Ross J.
    Rusko, Laszlo
    Wiesinger, Florian
    McCallum, Hazel M.
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3144 - S3147