Automated on-line liquid-liquid extraction in a multisyringe flow injection analysis manifold for migration studies in food-contact materials: analysis of 4,4?-dihydroxybiphenyl

被引:1
作者
Delgado-Blanca, I. [1 ]
Llorent-Martinez, E. J. [1 ]
Ruiz-Medina, A. [1 ]
Pilar, Ortega-Barrales [1 ]
机构
[1] Univ Jaen, Fac Expt Sci, Dept Phys & Analyt Chem, Campus Las Lagunillas, E-23071 Jaen, Spain
来源
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT | 2020年 / 37卷 / 01期
关键词
Olive oil; food contact; migration; polymer; multisyringe flow injection analysis; liquid-liquid extraction; MICROEXTRACTION; CHEMICALS; POLYMERS;
D O I
10.1080/19440049.2019.1678769
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Packaging may represent a source of food contamination, as different organic compounds and degradation compounds may migrate from packaging to foodstuff. For fatty foods, rectified olive oil is the common simulant, which implies time-consuming and laborious liquid-liquid extraction (LLE) procedures to isolate the contaminant(s) from the oil. Here we propose a Multisyringe Flow Injection Analysis manifold to automate this sample treatment, using the monomer 4,4?-dihydroxybiphenyl as the contaminant. The LLE procedure, using water as extractant, was fully automated. After the on-line LLE, the resulting extract was pumped through a fluorescence detector, inside which a flow-cell filled with C-18 silica gel solid support was placed. The analyte was pre-concentrated on the solid support (in which the analytical signal was directly recorded), so improving the sensitivity of the system. Under optimum conditions, the method detection limit is 0.05 mg kg(?1), well within the specific migration limit of 6 mg kg(?1). The method developed was compared with the standard CEN test method (off-line LLE and HPLC determination) observing savings in sample and reagents of 90% and a 7-fold increase in sample throughput.
引用
收藏
页码:174 / 182
页数:9
相关论文
共 26 条
[21]   Effects of the environmental oestrogens bisphenol A, tetrachlorobisphenol A, tetrabromobisphenol A, 4-hydroxybiphenyl and 4,4′-dihydroxybiphenyl on oestrogen receptor binding, cell proliferation and regulation of oestrogen sensitive proteins in the human breast cancer cell line MCF-7 [J].
Olsen, CM ;
Meussen-Elholm, ETM ;
Samuelsen, M ;
Holme, JA ;
Hongslo, JK .
PHARMACOLOGY & TOXICOLOGY, 2003, 92 (04) :180-188
[22]   Analytical strategies for organic food packaging contaminants [J].
Sanchis, Yovana ;
Yusa, Vicent ;
Coscolla, Clara .
JOURNAL OF CHROMATOGRAPHY A, 2017, 1490 :22-46
[23]   Liquid-liquid extraction in flow analysis: A critical review [J].
Silvestre, Cristina I. C. ;
Santos, Joao L. M. ;
Lima, Jose L. F. C. ;
Zagatto, Elias A. G. .
ANALYTICA CHIMICA ACTA, 2009, 652 (1-2) :54-65
[24]   A novel dual-valve sequential injection manifold (DV-SIA) for automated liquid-liquid extraction. Application for the determination of picric acid [J].
Skrlikova, Jana ;
Andruch, Vasil ;
Sklenarova, Hana ;
Chocholous, Petr ;
Solich, Petr ;
Balogh, Ioseph S. .
ANALYTICA CHIMICA ACTA, 2010, 666 (1-2) :55-61
[25]   Green aspects, developments and perspectives of liquid phase microextraction techniques [J].
Spietelun, Agata ;
Marcinkowski, Lukasz ;
de la Guardia, Miguel ;
Namiesnik, Jacek .
TALANTA, 2014, 119 :34-45
[26]   Fully-automated magnetic stirring-assisted lab-in-syringe dispersive liquid-liquid microextraction for the determination of arsenic species in rice samples [J].
Wang, Xiaojun ;
Xu, Guoliang ;
Chen, Peng ;
Sun, Yueshu ;
Yao, Xiaoting ;
Lv, Yan ;
Guo, Weiwei ;
Wang, Guozhen .
RSC ADVANCES, 2018, 8 (30) :16858-16865