A Review on Structural Fire Tests of Two-Way Composite Floors

被引:3
作者
Orabi, Mhd Anwar [1 ]
Jiang, Liming [1 ]
Huang, Xinyan [1 ]
Usmani, Asif [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Environm & Energy Engn, Res Ctr Fire Safety Engn, Hong Kong, Peoples R China
关键词
Slab; Steel construction; Tall buildings; Structure fire design; Tensile membrane action; REINFORCED-CONCRETE SLABS; TENSILE MEMBRANE ACTION; BEHAVIOR; STEEL; SYSTEMS;
D O I
10.1007/s10694-022-01277-4
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The utilisation of composite floor systems in modern construction allows for building large floor areas with efficient use of material and labour. The efficiency of this flooring system in carrying ambient loads as well as the thermal thinness of its steel framing makes it hypothetically sensitive to fire loads as a small exposure time may result in a rapid increase in temperature. However, a series of fire events and then large-scale experiments at the turn of the century demonstrated that composite floors could display surprising robustness in the face of high temperatures. Soon after, the total collapse of the World Trade Center towers 1, 2 and 7 showed the opposite. For the two decades since then, a large amount of experimental and theoretical work has been performed on this topic. This review aims to formulate an understanding of the thermo-mechanical behaviour of composite floors in fire, and to leverage that understanding to design more efficient and more robust buildings. We first surveyed the literature, and then summarized the composite floors being studied into three categories: isolated composite slab panels, composite floor assemblies, and large-scale tests. Then, theoretical design and analysis methods are discussed in light of the reviewed literature. Finally, this review coalesces the knowledge generated from the literature and lists the remaining challenges in the area, and set out a set of recommendations for designing composite floor systems for fire.
引用
收藏
页码:2533 / 2587
页数:55
相关论文
共 75 条
  • [61] Steel Construction Institute, 1991, STRUCT FIR ENG INV B
  • [62] Experimental and numerical evaluation of composite floor systems under fire conditions
    Tan, K. -H.
    Nguyen, T. -T.
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 105 : 86 - 96
  • [63] Limit capacity of laterally restrained reinforced concrete floor slabs in fire
    Usmani, AS
    Cameron, NJK
    [J]. CEMENT & CONCRETE COMPOSITES, 2004, 26 (02) : 127 - 140
  • [64] Fundamental principles of structural behaviour under thermal effects
    Usmani, AS
    Rotter, JM
    Lamont, S
    Sanad, AM
    Gillie, M
    [J]. FIRE SAFETY JOURNAL, 2001, 36 (08) : 721 - 744
  • [65] Vassart O, 2011, FRACOF FIRE RESISTAN
  • [66] Vassart O, 2012, MACS ENG BACKGROUND
  • [67] A fire test on continuous reinforced concrete slabs in a full-scale multi-story steel-framed building
    Wang, Y.
    Dong, Y. -L.
    Li, B.
    Zhou, G. -C.
    [J]. FIRE SAFETY JOURNAL, 2013, 61 : 232 - 242
  • [68] Performance of steel-concrete composite structures in fire
    Wang, YC
    [J]. PROGRESS IN STRUCTURAL ENGINEERING AND MATERIALS, 2005, 7 (02) : 86 - 102
  • [69] Wellman E., 2010, STRUCT C, V2010, P1310, DOI [10.1061/41130(369)119, DOI 10.1061/41130(369)119]
  • [70] Experimental Evaluation of Thin Composite Floor Assemblies under Fire Loading
    Wellman, Emily I.
    Varma, Amit H.
    Fike, Rustin
    Kodur, Venkatesh
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2011, 137 (09) : 1002 - 1016