Performance of the matrix-assisted laser desorption ionization time-of-flight mass spectrometry system for rapid identification of streptococci: a review

被引:27
|
作者
Fan, W. -T. [1 ]
Qin, T. -T. [1 ]
Bi, R. -R. [1 ]
Kang, H. -Q. [1 ,2 ]
Ma, P. [1 ,2 ]
Gu, B. [1 ,2 ]
机构
[1] Xuzhou Med Univ, Med Technol Inst, Xuzhou 221004, Peoples R China
[2] Xuzhou Med Univ, Affiliated Hosp, Dept Lab Med, 99 West Huaihai Rd, Xuzhou 221006, Peoples R China
关键词
MALDI-TOF-MS; BLOOD CULTURE BOTTLES; BRUKER MICROFLEX LT; VITEK MS; DESORPTION/IONIZATION-TIME; ROUTINE IDENTIFICATION; SPECIES IDENTIFICATION; HEMOLYTIC STREPTOCOCCI; VIRIDANS STREPTOCOCCI; BACTERIA;
D O I
10.1007/s10096-016-2879-2
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been developed as a new type of soft ionization mass spectrometry in recent years. An increasing number of clinical microbiological laboratories consider it as an innovative approach for bacterial identification. This study was undertaken in order to evaluate the use of MALDI-TOF MS for rapid identification of the clinical streptococci. A systematic review was conducted based on a literature search of the Medline and Embase databases. Fixed-effects models based on the P-value and the I-square were used for meta-analysis while considering the possibility of heterogeneity between studies. Statistical analyses were performed by using STATA 11.0. Twenty-seven studies covering 3,540 streptococci were included in our meta-analysis. The MALDI-TOF MS correctly identified the species of 96% (I-2 = 92.8, P < 0.1) of the streptococci. The MALDI-TOF MS correctly identified the species of 99% of the Streptococcus pneumoniae (I-2 = 85.2%, P < 0.1), 100% of the Streptococcus pyogenes (I-2 = 32.8%, P > 0.1), and 100% of Streptococcus agalactiae (I-2 = 20.7%, P > 0.2). What's more, it also had high confidence in other Streptococcus. But the accuracy of bovis needs to be improved. The overall performance of both MALDI-MS systems was different. Notably, the identifying accuracy rate of streptococci by VITEK MS was 98%, compared to 94% by the MALDI biotyper system. Interestingly, when analyzing the incorrect identification of MALDI-TOF MS, 36 out of the 38 strains of Streptococcus mitis/oralis were inaccurately identified as Streptococcus pneumoniae by the MALDI biotyper system. In conclusion, the results of this review indicated that MALDI-TOF MS could be a reliable and rapid method for identification of the streptococci.
引用
收藏
页码:1005 / 1012
页数:8
相关论文
共 50 条
  • [31] Microorganisms direct identification from blood culture by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
    Ferreira, L.
    Sanchez-Juanes, F.
    Porras-Guerra, I.
    Garcia-Garcia, M. I.
    Garcia-Sanchez, J. E.
    Gonzalez-Buitrago, J. M.
    Munoz-Bellido, J. L.
    CLINICAL MICROBIOLOGY AND INFECTION, 2011, 17 (04) : 546 - 551
  • [32] Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry identification of Archaea: towards the universal identification of living organisms
    Dridi, Bedis
    Raoult, Didier
    Drancourt, Michel
    APMIS, 2012, 120 (02) : 85 - 91
  • [33] Identification of Cronobacter species by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry with an optimized analysis method
    Wang, Qi
    Zhao, Xiao-Juan
    Wang, Zi-Wei
    Liu, Li
    Wei, Yong-Xin
    Han, Xiao
    Zeng, Jing
    Liao, Wan-Jin
    JOURNAL OF MICROBIOLOGICAL METHODS, 2017, 139 : 172 - 180
  • [34] Identification of Enterobacteriaceae by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry using the VITEK MS system
    Richter, S. S.
    Sercia, L.
    Branda, J. A.
    Burnham, C. -A. D.
    Bythrow, M.
    Ferraro, M. J.
    Garner, O. B.
    Ginocchio, C. C.
    Jennemann, R.
    Lewinski, M. A.
    Manji, R.
    Mochon, A. B.
    Rychert, J. A.
    Westblade, L. F.
    Procop, G. W.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2013, 32 (12) : 1571 - 1578
  • [35] Rapid Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry Imaging with Scanning Desorption Laser Beam
    Bednarik, Antonin
    Kuba, Pavel
    Moskovets, Eugene
    Tomalova, Iva
    Krasensky, Pavel
    Houska, Pavel
    Preisler, Jan
    ANALYTICAL CHEMISTRY, 2014, 86 (02) : 982 - 986
  • [36] Review on matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for the rapid screening of microbial species: A promising bioanalytical tool
    Kailasa, Suresh Kumar
    Koduru, Janardhan Reddy
    Baek, Seung Hoon
    Wu, Hui-Fen
    Hussain, Chaudhery Mustansar
    Park, Tae Jung
    MICROCHEMICAL JOURNAL, 2020, 159
  • [37] Evaluation of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for the discrimination of Lacticaseibacillus species
    Kim, Eiseul
    Yang, Seung-Min
    Cho, Eun-Ji
    Kim, Hae-Yeong
    FOOD MICROBIOLOGY, 2022, 107
  • [38] Evaluation of VITEK matrix-assisted laser desorption ionization-time of flight mass spectrometry for identification of anaerobes
    Xiao, Zheng
    Luo, Yanping
    Ye, Liyan
    Wang, Rui
    Zhang, Ying
    Zhao, Qiang
    Guo, Ling
    Ma, Yanning
    Cui, Shenghui
    MICROBIOLOGY AND IMMUNOLOGY, 2016, 60 (07) : 477 - 482
  • [39] Evaluation of VITEK Mass Spectrometry (MS), a Matrix-Assisted Laser Desorption Ionization Time-of-Flight MS System for Identification of Anaerobic Bacteria
    Lee, Wonmok
    Kim, Myungsook
    Yong, Dongeun
    Jeong, Seok Hoon
    Lee, Kyungwon
    Chong, Yunsop
    ANNALS OF LABORATORY MEDICINE, 2015, 35 (01) : 69 - 75
  • [40] Use of Matrix-Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometry for the Identification of Pathogenic Vibrio in Fish
    Burbick, Claire R.
    Nydam, Seth D.
    Hendrix, G. Kenitra
    Besser, Thomas E.
    Diaz, Dubraska
    Snekvik, Kevin
    JOURNAL OF AQUATIC ANIMAL HEALTH, 2018, 30 (04) : 332 - 338