Performance of the matrix-assisted laser desorption ionization time-of-flight mass spectrometry system for rapid identification of streptococci: a review

被引:28
作者
Fan, W. -T. [1 ]
Qin, T. -T. [1 ]
Bi, R. -R. [1 ]
Kang, H. -Q. [1 ,2 ]
Ma, P. [1 ,2 ]
Gu, B. [1 ,2 ]
机构
[1] Xuzhou Med Univ, Med Technol Inst, Xuzhou 221004, Peoples R China
[2] Xuzhou Med Univ, Affiliated Hosp, Dept Lab Med, 99 West Huaihai Rd, Xuzhou 221006, Peoples R China
关键词
MALDI-TOF-MS; BLOOD CULTURE BOTTLES; BRUKER MICROFLEX LT; VITEK MS; DESORPTION/IONIZATION-TIME; ROUTINE IDENTIFICATION; SPECIES IDENTIFICATION; HEMOLYTIC STREPTOCOCCI; VIRIDANS STREPTOCOCCI; BACTERIA;
D O I
10.1007/s10096-016-2879-2
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been developed as a new type of soft ionization mass spectrometry in recent years. An increasing number of clinical microbiological laboratories consider it as an innovative approach for bacterial identification. This study was undertaken in order to evaluate the use of MALDI-TOF MS for rapid identification of the clinical streptococci. A systematic review was conducted based on a literature search of the Medline and Embase databases. Fixed-effects models based on the P-value and the I-square were used for meta-analysis while considering the possibility of heterogeneity between studies. Statistical analyses were performed by using STATA 11.0. Twenty-seven studies covering 3,540 streptococci were included in our meta-analysis. The MALDI-TOF MS correctly identified the species of 96% (I-2 = 92.8, P < 0.1) of the streptococci. The MALDI-TOF MS correctly identified the species of 99% of the Streptococcus pneumoniae (I-2 = 85.2%, P < 0.1), 100% of the Streptococcus pyogenes (I-2 = 32.8%, P > 0.1), and 100% of Streptococcus agalactiae (I-2 = 20.7%, P > 0.2). What's more, it also had high confidence in other Streptococcus. But the accuracy of bovis needs to be improved. The overall performance of both MALDI-MS systems was different. Notably, the identifying accuracy rate of streptococci by VITEK MS was 98%, compared to 94% by the MALDI biotyper system. Interestingly, when analyzing the incorrect identification of MALDI-TOF MS, 36 out of the 38 strains of Streptococcus mitis/oralis were inaccurately identified as Streptococcus pneumoniae by the MALDI biotyper system. In conclusion, the results of this review indicated that MALDI-TOF MS could be a reliable and rapid method for identification of the streptococci.
引用
收藏
页码:1005 / 1012
页数:8
相关论文
共 50 条
[41]   Mass spectrometry tools for the classification and identification of bacteria [J].
Sauer, Sascha ;
Kliem, Magdalena .
NATURE REVIEWS MICROBIOLOGY, 2010, 8 (01) :74-82
[42]   Progress in proteomics for clinical microbiology: MALDI-TOF MS for microbial species identification and more [J].
van Belkum, Alex ;
Chatellier, Sonia ;
Girard, Victoria ;
Pincus, David ;
Deol, Parampal ;
Dunne, Wm Michael, Jr. .
EXPERT REVIEW OF PROTEOMICS, 2015, 12 (06) :595-605
[43]   MALDI-TOF mass spectrometry for differentiation between Streptococcus pneumoniae and Streptococcus pseudopneumoniae [J].
van Prehn, Joffrey ;
van Veen, Suzanne Q. ;
Schelfaut, Jacqueline J. G. ;
Wessels, Els .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2016, 85 (01) :9-11
[44]   High-Throughput Identification of Bacteria and Yeast by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry in Conventional Medical Microbiology Laboratories [J].
van Veen, S. Q. ;
Claas, E. C. J. ;
Kuijper, Ed J. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (03) :900-907
[45]   Identification and Cluster Analysis of Streptococcus pyogenes by MALDI-TOF Mass Spectrometry [J].
Wang, Jie ;
Zhou, Na ;
Xu, Bin ;
Hao, Huaijie ;
Kang, Lin ;
Zheng, Yuling ;
Jiang, Yongqiang ;
Jiang, Hua .
PLOS ONE, 2012, 7 (11)
[46]   QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies [J].
Whiting, Penny F. ;
Rutjes, Anne W. S. ;
Westwood, Marie E. ;
Mallett, Susan ;
Deeks, Jonathan J. ;
Reitsma, Johannes B. ;
Leeflang, Mariska M. G. ;
Sterne, Jonathan A. C. ;
Bossuyt, Patrick M. M. .
ANNALS OF INTERNAL MEDICINE, 2011, 155 (08) :529-U104
[47]   The Construction and Evaluation of Reference Spectra for the Identification of Human Pathogenic Microorganisms by MALDI-TOF MS [J].
Xiao, Di ;
Ye, Changyun ;
Zhang, Huifang ;
Kan, Biao ;
Lu, Jingxing ;
Xu, Jianguo ;
Jiang, Xiugao ;
Zhao, Fei ;
You, Yuanhai ;
Yan, Xiaomei ;
Wang, Duochun ;
Hu, Yuan ;
Zhang, Maojun ;
Zhang, Jianzhong .
PLOS ONE, 2014, 9 (09)
[48]   Rapid identification of microorganisms isolated from throat swab specimens of community-acquired pneumonia patients by two MALDI-TOF MS systems [J].
Xiao, Di ;
Zhao, Fei ;
Lv, Min ;
Zhang, Huifang ;
Zhang, Yongchan ;
Huang, Hui ;
Su, Peng ;
Zhang, Zhen ;
Zhang, Jianzhong .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2012, 73 (04) :301-307
[49]   Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for the identification of beta-hemolytic streptococci [J].
Zhou, Chunmei ;
Tao, Lili ;
Hu, Bijie ;
Ma, Jian ;
Ye, Xiangru ;
Huang, Shenglei ;
Ma, Yan ;
Shan, Yuzhang .
JOURNAL OF THORACIC DISEASE, 2015, 7 (04) :591-595
[50]   The value of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry in identifying clinically relevant bacteria: a comparison with automated microbiology system [J].
Zhou, Chunmei ;
Hu, Bijie ;
Zhang, Xuelian ;
Huang, Shenglei ;
Shan, Yuzhang ;
Ye, Xiangru .
JOURNAL OF THORACIC DISEASE, 2014, 6 (05) :545-552