Performance of the matrix-assisted laser desorption ionization time-of-flight mass spectrometry system for rapid identification of streptococci: a review

被引:28
作者
Fan, W. -T. [1 ]
Qin, T. -T. [1 ]
Bi, R. -R. [1 ]
Kang, H. -Q. [1 ,2 ]
Ma, P. [1 ,2 ]
Gu, B. [1 ,2 ]
机构
[1] Xuzhou Med Univ, Med Technol Inst, Xuzhou 221004, Peoples R China
[2] Xuzhou Med Univ, Affiliated Hosp, Dept Lab Med, 99 West Huaihai Rd, Xuzhou 221006, Peoples R China
关键词
MALDI-TOF-MS; BLOOD CULTURE BOTTLES; BRUKER MICROFLEX LT; VITEK MS; DESORPTION/IONIZATION-TIME; ROUTINE IDENTIFICATION; SPECIES IDENTIFICATION; HEMOLYTIC STREPTOCOCCI; VIRIDANS STREPTOCOCCI; BACTERIA;
D O I
10.1007/s10096-016-2879-2
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been developed as a new type of soft ionization mass spectrometry in recent years. An increasing number of clinical microbiological laboratories consider it as an innovative approach for bacterial identification. This study was undertaken in order to evaluate the use of MALDI-TOF MS for rapid identification of the clinical streptococci. A systematic review was conducted based on a literature search of the Medline and Embase databases. Fixed-effects models based on the P-value and the I-square were used for meta-analysis while considering the possibility of heterogeneity between studies. Statistical analyses were performed by using STATA 11.0. Twenty-seven studies covering 3,540 streptococci were included in our meta-analysis. The MALDI-TOF MS correctly identified the species of 96% (I-2 = 92.8, P < 0.1) of the streptococci. The MALDI-TOF MS correctly identified the species of 99% of the Streptococcus pneumoniae (I-2 = 85.2%, P < 0.1), 100% of the Streptococcus pyogenes (I-2 = 32.8%, P > 0.1), and 100% of Streptococcus agalactiae (I-2 = 20.7%, P > 0.2). What's more, it also had high confidence in other Streptococcus. But the accuracy of bovis needs to be improved. The overall performance of both MALDI-MS systems was different. Notably, the identifying accuracy rate of streptococci by VITEK MS was 98%, compared to 94% by the MALDI biotyper system. Interestingly, when analyzing the incorrect identification of MALDI-TOF MS, 36 out of the 38 strains of Streptococcus mitis/oralis were inaccurately identified as Streptococcus pneumoniae by the MALDI biotyper system. In conclusion, the results of this review indicated that MALDI-TOF MS could be a reliable and rapid method for identification of the streptococci.
引用
收藏
页码:1005 / 1012
页数:8
相关论文
共 50 条
[1]   Rapid identification of bacteria from positive blood culture bottles by MALDI-TOF MS following short-term incubation on solid media [J].
Altun, Osman ;
Botero-Kleiven, Silvia ;
Carlsson, Sarah ;
Ullberg, Mans ;
Ozenci, Volkan .
JOURNAL OF MEDICAL MICROBIOLOGY, 2015, 64 :1346-1352
[2]   Mechanisms of genome evolution of Streptococcus [J].
Andam, Cheryl P. ;
Hanage, William P. .
INFECTION GENETICS AND EVOLUTION, 2015, 33 :334-342
[3]   Viridans Group Streptococci Clinical Isolates: MALDI-TOF Mass Spectrometry versus Gene Sequence-Based Identification [J].
Angeletti, Silvia ;
Dicuonzo, Giordano ;
Avola, Alessandra ;
Crea, Francesca ;
Dedej, Etleva ;
Vailati, Francesca ;
Farina, Claudio ;
De Florio, Lucia .
PLOS ONE, 2015, 10 (03)
[4]   EVALUATION OF THE RAPID STREP SYSTEM FOR SPECIES IDENTIFICATION OF STREPTOCOCCI [J].
APPELBAUM, PC ;
CHAURUSHIYA, PS ;
JACOBS, MR ;
DUFFETT, A .
JOURNAL OF CLINICAL MICROBIOLOGY, 1984, 19 (05) :588-591
[5]   Comparing Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry and Phenotypic and Molecular Methods for Identification of Species within the Streptococcus anginosus Group [J].
Arinto-Garcia, Raquel ;
Pinho, Marcos Daniel ;
Carrico, Joao Andre ;
Melo-Cristino, Jose ;
Ramirez, Mario .
JOURNAL OF CLINICAL MICROBIOLOGY, 2015, 53 (11) :3580-3588
[6]   Performances and Reliability of Bruker Microflex LT and VITEK MS MALDI-TOF Mass Spectrometry Systems for the Identification of Clinical Microorganisms [J].
Bilecen, Kivanc ;
Yaman, Gorkem ;
Ciftci, Ugur ;
Laleli, Yahya Rauf .
BIOMED RESEARCH INTERNATIONAL, 2015, 2015
[7]   Performance of the Vitek MS v2.0 System in Distinguishing Streptococcus pneumoniae from Nonpneumococcal Species of the Streptococcus mitis Group [J].
Branda, John A. ;
Markham, Rachelle P. ;
Garner, Cherilyn D. ;
Rychert, Jenna A. ;
Ferraro, Mary Jane .
JOURNAL OF CLINICAL MICROBIOLOGY, 2013, 51 (09) :3079-3082
[8]   Phoenix 100 versus Vitek 2 in the Identification of Gram-Positive and Gram-Negative Bacteria: a Comprehensive Meta-Analysis [J].
Chatzigeorgiou, Kalliopi-Stavroula ;
Sergentanis, Theodoros N. ;
Tsiodras, Sotirios ;
Hamodrakas, Stavros J. ;
Bagos, Pantelis G. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (09) :3284-3291
[9]   Evaluation of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Rapid Identification of Beta-Hemolytic Streptococci [J].
Cherkaoui, Abdessalam ;
Emonet, Stephane ;
Fernandez, Jose ;
Schorderet, Didier ;
Schrenzel, Jacques .
JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (08) :3004-3005
[10]   Comparison of Two Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Methods with Conventional Phenotypic Identification for Routine Identification of Bacteria to the Species Level [J].
Cherkaoui, Abdessalam ;
Hibbs, Jonathan ;
Emonet, Stephane ;
Tangomo, Manuela ;
Girard, Myriam ;
Francois, Patrice ;
Schrenzel, Jacques .
JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (04) :1169-1175