Performance of the matrix-assisted laser desorption ionization time-of-flight mass spectrometry system for rapid identification of streptococci: a review

被引:27
|
作者
Fan, W. -T. [1 ]
Qin, T. -T. [1 ]
Bi, R. -R. [1 ]
Kang, H. -Q. [1 ,2 ]
Ma, P. [1 ,2 ]
Gu, B. [1 ,2 ]
机构
[1] Xuzhou Med Univ, Med Technol Inst, Xuzhou 221004, Peoples R China
[2] Xuzhou Med Univ, Affiliated Hosp, Dept Lab Med, 99 West Huaihai Rd, Xuzhou 221006, Peoples R China
关键词
MALDI-TOF-MS; BLOOD CULTURE BOTTLES; BRUKER MICROFLEX LT; VITEK MS; DESORPTION/IONIZATION-TIME; ROUTINE IDENTIFICATION; SPECIES IDENTIFICATION; HEMOLYTIC STREPTOCOCCI; VIRIDANS STREPTOCOCCI; BACTERIA;
D O I
10.1007/s10096-016-2879-2
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been developed as a new type of soft ionization mass spectrometry in recent years. An increasing number of clinical microbiological laboratories consider it as an innovative approach for bacterial identification. This study was undertaken in order to evaluate the use of MALDI-TOF MS for rapid identification of the clinical streptococci. A systematic review was conducted based on a literature search of the Medline and Embase databases. Fixed-effects models based on the P-value and the I-square were used for meta-analysis while considering the possibility of heterogeneity between studies. Statistical analyses were performed by using STATA 11.0. Twenty-seven studies covering 3,540 streptococci were included in our meta-analysis. The MALDI-TOF MS correctly identified the species of 96% (I-2 = 92.8, P < 0.1) of the streptococci. The MALDI-TOF MS correctly identified the species of 99% of the Streptococcus pneumoniae (I-2 = 85.2%, P < 0.1), 100% of the Streptococcus pyogenes (I-2 = 32.8%, P > 0.1), and 100% of Streptococcus agalactiae (I-2 = 20.7%, P > 0.2). What's more, it also had high confidence in other Streptococcus. But the accuracy of bovis needs to be improved. The overall performance of both MALDI-MS systems was different. Notably, the identifying accuracy rate of streptococci by VITEK MS was 98%, compared to 94% by the MALDI biotyper system. Interestingly, when analyzing the incorrect identification of MALDI-TOF MS, 36 out of the 38 strains of Streptococcus mitis/oralis were inaccurately identified as Streptococcus pneumoniae by the MALDI biotyper system. In conclusion, the results of this review indicated that MALDI-TOF MS could be a reliable and rapid method for identification of the streptococci.
引用
收藏
页码:1005 / 1012
页数:8
相关论文
共 50 条
  • [2] Identification of Aeromonas isolates by matrix-assisted laser desorption ionization time-of-flight mass spectrometry
    Lamy, Brigitte
    Kodjo, Angeli
    Laurent, Frederic
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2011, 71 (01) : 1 - 5
  • [3] Rapid identification of clinical isolates of Bacteroides species by matrix-assisted laser-desorption/ionization time-of-flight mass spectrometry
    Culebras, Esther
    Rodriguez-Avial, Iciar
    Betriu, Carmen
    Gomez, Maria
    Picazo, Juan J.
    ANAEROBE, 2012, 18 (01) : 163 - 165
  • [4] Matrix-Assisted Laser Desorption Ionization Time-of-Flight for Fungal Identification
    Lau, Anna F.
    CLINICS IN LABORATORY MEDICINE, 2021, 41 (02) : 267 - 283
  • [5] Rapid characterization of aquatic hyphomycetes by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
    Cornut, Julien
    De Respinis, Sophie
    Tonolla, Mauro
    Petrini, Orlando
    Barlocher, Felix
    Chauvet, Eric
    Bruder, Andreas
    MYCOLOGIA, 2019, 111 (01) : 177 - 189
  • [6] Matrix-assisted laser desorption ionization time-of-flight mass spectrometry for bacterial strain characterization
    Lartigue, Marie-Frederique
    INFECTION GENETICS AND EVOLUTION, 2013, 13 : 230 - 235
  • [7] Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for the identification of beta-hemolytic streptococci
    Zhou, Chunmei
    Tao, Lili
    Hu, Bijie
    Ma, Jian
    Ye, Xiangru
    Huang, Shenglei
    Ma, Yan
    Shan, Yuzhang
    JOURNAL OF THORACIC DISEASE, 2015, 7 (04) : 591 - 595
  • [8] Rapid identification of medically important mosquitoes by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
    Mewara, Abhishek
    Sharma, Megha
    Kaura, Taruna
    Zaman, Kamran
    Yadav, Rakesh
    Sehgal, Rakesh
    PARASITES & VECTORS, 2018, 11
  • [9] Matrix-assisted laser desorption ionization time-of-flight mass spectrometry and database for identification of Legionella species
    He, Ying
    Chang, Tsung C.
    Li, Haijing
    Shi, Gongyi
    Tang, Yi-Wei
    CANADIAN JOURNAL OF MICROBIOLOGY, 2011, 57 (07) : 533 - 538
  • [10] Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for rapid identification of fungal rhinosinusitis pathogens
    Huang, Yanfei
    Wang, Jinglin
    Zhang, Mingxin
    Zhu, Min
    Wang, Mei
    Sun, Yufeng
    Gu, Haitong
    Cao, Jingjing
    Li, Xue
    Zhang, Shaoya
    Lu, Xinxin
    JOURNAL OF MEDICAL MICROBIOLOGY, 2017, 66 (03) : 328 - 333