Refractive Power and Biometric Properties of the Nonhuman Primate Isolated Crystalline Lens

被引:18
|
作者
Borja, David [1 ,2 ]
Manns, Fabrice [1 ,2 ]
Ho, Arthur [3 ,4 ,5 ]
Ziebarth, Noel M. [1 ,2 ]
Acosta, Ana Carolina [1 ]
Arrieta-Quintera, Esdras [1 ]
Augusteyn, Robert C. [3 ,4 ,5 ]
Parel, Jean-Marie [1 ,2 ,5 ,6 ]
机构
[1] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, Ophthalm Biophys Ctr, Miami, FL 33136 USA
[2] Univ Miami, Biomed Opt & Laser Lab, Dept Biomed Engn, Coral Gables, FL 33124 USA
[3] Eye Res Inst, Sydney, NSW, Australia
[4] Univ New S Wales, Sch Optometry & Vis Sci, Sydney, NSW, Australia
[5] Vis Cooperat Res Ctr, Sydney, NSW, Australia
[6] Univ Liege, CHU Sart Tillmann, CHU Dept Ophthalmol, Liege, Belgium
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
RHESUS-MONKEY EYE; SLIT-LAMP; PHACO-ERSATZ; ACCOMMODATION; AGE; ANTERIOR; SILICONE; SHAPE; CURVATURE; THICKNESS;
D O I
10.1167/iovs.09-3905
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To characterize the age dependence of shape, refractive power, and refractive index of isolated lenses from nonhuman primates. METHODS. Measurements were performed on ex vivo lenses from cynomolgus monkeys (cyno: n = 120; age, 2.7-14.3 years), rhesus monkeys (n = 61; age, 0.7-13.3 years), and hamadryas baboons (baboon: n = 16; age, 1.7-27.3 years). Lens thickness, diameter, and surface curvatures were measured with an optical comparator. Lens refractive power was measured with a custom optical system based on the Scheiner principle. The refractive contributions of the gradient, the surfaces, and the equivalent refractive index were calculated with optical ray-tracing software. The age dependence of the optical and biometric parameters was assessed. RESULTS. Over the measured age range isolated lens thickness decreased (baboon: -0.04, cyno: -0.05, and rhesus: -0.06 mm/y) and equatorial diameter increased (logarithmically for the baboon and rhesus, and linearly for cyno: 0.07 mm/y). The isolated lens surfaces flattened and the corresponding refractive power from the surfaces decreased with age (-0.33, -0.48, and -0.68 D/y). The isolated lens equivalent refractive index decreased (only significant for the baboon, -0.001 D/y), and as a result the total isolated lens refractive power decreased with age (baboon: -1.26, cyno: -0.97, and rhesus: -1.76 D/y). CONCLUSIONS. The age-dependent trends in the optical and biometric properties, growth, and aging, of nonhuman primate lenses are similar to those of the pre-presbyopic human lens. As the lens ages, the decrease in refractive contributions from the gradient refractive index causes a rapid age-dependent decrease in maximally accommodated lens refractive power. (Invest Ophthalmol Vis Sci. 2010; 51: 2118-2125) DOI:10.1167/iovs.09-3905
引用
收藏
页码:2118 / 2125
页数:8
相关论文
共 50 条
  • [1] Crystalline Lens Power and Refractive Error
    Iribarren, Rafael
    Morgan, Ian G.
    Nangia, Vinay
    Jonas, Jost B.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (02) : 543 - 550
  • [2] Influence of Shape and Gradient Refractive Index in the Accommodative Changes of Spherical Aberration in Nonhuman Primate Crystalline Lenses
    de Castro, Alberto
    Birkenfeld, Judith
    Maceo, Bianca
    Manns, Fabrice
    Arrieta, Esdras
    Parel, Jean-Marie
    Marcos, Susana
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (09) : 6197 - 6207
  • [3] Biometric, optical and physical changes in the isolated human crystalline lens with age in relation to presbyopia
    Glasser, A
    Campbell, MCW
    VISION RESEARCH, 1999, 39 (11) : 1991 - 2015
  • [4] In vivo measurement of the human crystalline lens equivalent refractive index using extended-depth OCT
    Chang, Yu-Cherng
    Mesquita, Gabrielle Monterano
    Williams, Siobhan
    Gregori, Giovanni
    Cabot, Florence
    Ho, Arthur
    Ruggeri, Marco
    Yoo, Sonia H.
    Parel, Jean-Marie
    Manns, Fabrice
    BIOMEDICAL OPTICS EXPRESS, 2019, 10 (02): : 411 - 422
  • [5] Biometric changes of the crystalline lens during accommodation
    Hirnschall, Nino
    Kiss, Barbara
    Guer, Ayfer
    Findl, Oliver
    SPEKTRUM DER AUGENHEILKUNDE, 2021, 35 (06) : 221 - 228
  • [6] The Relationship between Crystalline Lens Power and Refractive Error in Older Chinese Adults: The Shanghai Eye Study
    He, Jiangnan
    Lu, Lina
    He, Xiangui
    Xu, Xian
    Du, Xuan
    Zhang, Bo
    Zhao, Huijuan
    Sha, Jida
    Zhu, Jianfeng
    Zou, Haidong
    Xu, Xun
    PLOS ONE, 2017, 12 (01):
  • [7] Calculation of crystalline lens power using a modification of the Bennett method
    Hernandez, Victor M.
    Cabot, Florence
    Ruggeri, Marco
    de Freitas, Carolina
    Ho, Arthur
    Yoo, Sonia
    Parel, Jean-Marie
    Manns, Fabrice
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (11): : 4501 - 4515
  • [8] Age dependence of the average refractive index of the isolated human crystalline lens
    Natarajan, Ramya
    Heilman, Bianca Maceo
    Ruggeri, Marco
    Ho, Arthur
    Singh, Vivek M.
    Auguseyn, Robert
    Parel, Jean-Marie
    Vaddavalli, Pravin K.
    Manns, Fabrice
    BIOMEDICAL OPTICS EXPRESS, 2024, 15 (10): : 5901 - 5911
  • [9] Isolated human crystalline lens three-dimensional shape: A comparison between Indian and European populations
    Mohamed, Ashik
    Nandyala, Sushma
    Martinez-Enriquez, Eduardo
    Heilman, Bianca Maceo
    Augusteyn, Robert C.
    de Castro, Alberto
    Ruggeri, Marco
    Parel, Jean-Marie A.
    Marcos, Susana
    Manns, Fabrice
    EXPERIMENTAL EYE RESEARCH, 2021, 205
  • [10] Refractive Index Measurement of the Crystalline Lens in Vivo
    He, Ji C.
    OPTOMETRY AND VISION SCIENCE, 2023, 100 (12) : 823 - 832