Root Canal Area Increase Promoted by the EndoSequence and ProTaper Systems: Comparison by Computed Tomography

被引:12
作者
Bernardes, Ricardo Affonso [1 ]
Rocha, Emerson Antunes [1 ]
Hungaro Duarte, Marco Antonio [2 ]
Vivan, Rodrigo Ricci [3 ]
de Moraes, Ivaldo Gomes [2 ]
Bramante, Alexandre S. [1 ]
de Azevedo, Jose Ribamar [4 ]
机构
[1] CPO SL Mand Brasiliense Dent Sch, Brasilia, DF, Brazil
[2] Univ Sao Paulo, Bauru Sch Dent, Dept Dent Dent Mat & Endodont, Bauru, SP, Brazil
[3] Sao Paulo State Univ, Dent Sch Araraquara, Dept Restorat Dent, Araraquara, SP, Brazil
[4] Inst Odonto Radiol Brasilia, Brasilia, DF, Brazil
关键词
Cone beam CT; EndoSequence; ProTaper; rotary systems; INSTRUMENTATION; ABILITY; DIAGNOSIS; FORCE; MOLAR; FILES;
D O I
10.1016/j.joen.2009.12.033
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The aim of this study was to compare the increase of the root canal area after instrumentation with EndoSequence or ProTaper rotary systems. Methods: Twenty-two mesial root canals from mandibular molars were instrumented. Teeth were mounted on a base, numbered, and divided into 2 groups; teeth from 1-11 (PT group) were instrumented by using the ProTaper system, and teeth from 12-22 (ES group) were instrumented by using the EndoSequence system. Cone beam computed tomography was performed on all teeth before and after instrumentation. Measurements at 3,5, and 7 mm as well as differences in instrument performance were statistically compared by the Student t test at 5% significance level. Results: Both systems increased significantly the root canal area (P < .05) at all levels. Comparison between the rotary systems showed significantly greater increase (P < .05) for EndoSequence at 3 mm, with no statistically significant difference (P < .05) at the other levels. Conclusions: Both rotary systems increased significantly the root canal area. (J Endod 2010;36:1179-1182)
引用
收藏
页码:1179 / 1182
页数:4
相关论文
共 26 条
[1]  
Arnheiter C., 2006, ORAL RADIOL, V22, P80, DOI DOI 10.1007/S11282-006-0055-6
[2]   Use of cone-beam volumetric tomography in the diagnosis of root fractures [J].
Bernardes, Ricardo Affonso ;
de Moraes, Ivaldo Gomes ;
Hungaro Duarte, Marco Antonio ;
Azevedo, Bruno C. ;
de Azevedo, Jose Ribamar ;
Bramante, Clovis Monteiro .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (02) :270-277
[3]   The Effect of Electropolishing on Torque and Force During Simulated Root Canal Preparation with ProTaper Shaping Files [J].
Boessler, Claudia ;
Paque, Frank ;
Peters, Ove A. .
JOURNAL OF ENDODONTICS, 2009, 35 (01) :102-106
[4]   Shaping ability of ProTaper nickel-titanium files in simulated resin root canals [J].
Calberson, FLG ;
Deroose, CAJG ;
Hommez, GMG ;
De Moor, RJG .
INTERNATIONAL ENDODONTIC JOURNAL, 2004, 37 (09) :613-623
[5]   Influence of the NiTi rotary system on the debridement quality of the root canal space [J].
De-Deus, Gustavo ;
Garcia-Filho, Paulo .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (04) :E71-E76
[6]   A New Periapical Index Based on Cone Beam Computed Tomography [J].
Estrela, Carlos ;
Bueno, Mike Reis ;
Azevedo, Bruno Correa ;
Azevedo, Jose Ribamar ;
Pecora, Jesus Djalma .
JOURNAL OF ENDODONTICS, 2008, 34 (11) :1325-1331
[7]   Comparative study of six rotary nickel-titanium systems and hand instrumentation for root canal preparation [J].
Guelzow, A ;
Stamm, O ;
Martus, P ;
Kielbassa, AM .
INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (10) :743-752
[8]   A scanning electron microscopy evaluation of microfractures, deformation and separation in EndoSequence and profile nickel-titanium rotary files using an extracted molar tooth model [J].
Herold, Keven S. ;
Johnson, Bradford R. ;
Wenckus, Christopher S. .
JOURNAL OF ENDODONTICS, 2007, 33 (06) :712-714
[9]   A Comparison of Apical Transportation and Length Control between EndoSequence and Guidance Rotary Instruments [J].
Karabucak, Bekir ;
Gatan, Adam Joseph ;
Hsiao, Chinchai ;
Iqbal, Mian Khalid .
JOURNAL OF ENDODONTICS, 2010, 36 (01) :123-125
[10]  
Kurtzman Gregori M, 2006, N Y State Dent J, V72, P56