VALIDITY AND RELIABILITY OF A NEW TEST OF UPPER BODY POWER

被引:39
作者
Clemons, James M. [1 ]
Campbell, Brian [1 ]
Jeansonne, Chris [1 ]
机构
[1] Univ Louisiana Lafayette, Dept Kinesiol, Human Performance Lab, Lafayette, LA 70506 USA
关键词
bench press power; medicine ball put; upper body power; BENCH PRESS; GRIP WIDTH; STRENGTH; ACCELERATION; PERFORMANCE; PLAYERS; WOMEN;
D O I
10.1519/JSC.0b013e3181dad222
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Clemons, JM, Campbell, B, and Jeansonne, C. Validity and reliability of a new test of upper body power. J Strength Cond Res 24(6): 1559-1565, 2010-The purpose of this study was to determine the concurrent validity of a new bench press power (BPP) test using the medicine ball put (MBP) as the criterion measure. Forty-three college-age students (19 males and 24 females) participated in the study. Participants performed 1 repetition at maximum speed using 61.4 kg (males) and 25 kg (females), at a grip width of 130% of biacromial breadth. Timing was initiated manually at the moment of upward bar movement and stopped automatically as the bar broke an infrared beam 0.3 m above the chest. All tests were conducted within 2 weeks. There was 1 practice session for the BPP test and 2 separate testing sessions, one for BPP and the other for the MBP. Three BPP trials were separated by >= 2 minutes of passive recovery. Individual scores were the average of the second and third tests and were expressed in Watts: Power = Bar mass kg.9.81-0.3m/s. Medicine ball put scores were the average distance the ball was thrown on the second and third trials from a sitting position on a 45 degrees recumbent weight bench. Concurrent validity was determined by conducting a Pearson Correlation on BPP and MBP scores at an alpha level of 0.05: males, r = 0.861; females, r = 0.79, (p < 0.000). In addition, results of an Intraclass R indicated excellent test-retest reliability for both males and females for BPP and the MBP (p < 0.05). The conclusion was that the BPP test is a logically and concurrently valid method for coaches and trainers to use in assessing upper body power for both college-age males and females.
引用
收藏
页码:1559 / 1565
页数:7
相关论文
共 50 条
[41]   RELIABILITY AND VALIDITY OF A MEDICINE BALL-CONTAINED ACCELEROMETER FOR MEASURING UPPER-BODY NEUROMUSCULAR PERFORMANCE [J].
Roe, Gregory ;
Shaw, William ;
Darrall-Jones, Joshua ;
Phibbs, Padraic J. ;
Read, Dale ;
Weakley, Jonathon J. ;
Till, Kevin ;
Jones, Ben .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2018, 32 (07) :1915-1918
[42]   Reliability and Validity of the Polhemus Liberty System for Upper Body Segment and Joint Angular Kinematics of Elite Golfers [J].
Wheare, Matilda Jane ;
Nelson, Maximillian J. ;
Lumsden, Ryan ;
Buttfield, Alec ;
Crowther, Robert George .
SENSORS, 2021, 21 (13)
[43]   A new instrument to assess physical function in stroke patients: the Dubousset function test and its validity, reliability, responsiveness [J].
Bozkurt, Yusuf Emre ;
Kocaman, Ayse Abit ;
Cavdar, Merve Kasikci ;
Keskin, E. Dilek .
NEUROLOGICAL RESEARCH, 2023, 45 (12) :1127-1135
[44]   Reliability and Validity of the Inline Skating Skill Test [J].
Radman, Ivan ;
Ruzic, Lana ;
Padovan, Viktoria ;
Cigrovski, Vjekoslav ;
Podnar, Hrvoje .
JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2016, 15 (03) :390-396
[45]   Reliability and Validity of the Kickboxing Anaerobic Speed Test [J].
Gencoglu, Cebrail ;
Ulupinar, Suleyman ;
ozbay, Serhat ;
Ouergui, Ibrahim ;
Franchini, Emerson .
RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2023, 94 (03) :715-724
[46]   Revision of the Osteoporosis Knowledge Test: Reliability and Validity [J].
Gendler, Phyllis Ellen ;
Coviak, Cynthia Peltier ;
Martin, Jean Thomas ;
Kim, Katherine K. ;
Dankers, Jennifer K. ;
Barclay, Julieanne Marie ;
Sanchez, Thomas A. .
WESTERN JOURNAL OF NURSING RESEARCH, 2015, 37 (12) :1623-1643
[47]   The Reliability and Validity of the Modified Butterfly Agility Test [J].
Cahanin, Richard ;
Burley, Troy ;
Waldhelm, Andy .
INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2025, 20 (05) :666-675
[48]   Validity and Reliability of the Hawaii Anaerobic Run Test [J].
Kimura, Iris F. ;
Stickley, Christopher D. ;
Lentz, Melissa A. ;
Wages, Jennifer J. ;
Yanagi, Kazuhiko ;
Hetzler, Ronald K. .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2014, 28 (05) :1386-1393
[49]   Validity and reliability of the Functional Dexterity Test in children [J].
Tissue, Camden M. ;
Velleman, Paul F. ;
Stegink-Jansen, Caroline W. ;
Aaron, Dorit Haenosh ;
Winthrop, Barbara G. ;
Gogola, Gloria R. .
JOURNAL OF HAND THERAPY, 2017, 30 (04) :500-506
[50]   Validity and reliability of the single-trial line drill test of anaerobic power in basketball players [J].
Fatouros, I. G. ;
Laparidis, K. ;
Kambas, A. ;
Chatzinikolaou, A. ;
Techlikidou, E. ;
Katrabasas, I. ;
Douroudos, I. ;
Leontsini, D. ;
Berberidou, F. ;
Draganidis, D. ;
Christoforidis, C. ;
Tsoukas, D. ;
Kelis, S. ;
Taxildaris, K. .
JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2011, 51 (01) :33-41