CFD simulation and second law analysis of weir-type cascade solar stills with different number and dimensions of steps

被引:30
作者
Alipanah, Fatemeh [1 ]
Rahbar, Nader [2 ,3 ]
机构
[1] Islamic Azad Univ, Dept Mech Engn, Semnan Branch, POB 35196-97951, Semnan, Iran
[2] Islamic Azad Univ, Semnan Branch, Young Researchers & Elite Clubs, Semnan, Iran
[3] Islamic Azad Univ, Semnan Branch, Energy & Sustainable Dev Res Ctr, POB 35196-97951, Semnan, Iran
关键词
CFD simulation; Weir-type cascade solar still; Double diffusive natural convection; Heat and mass transfer; Entropy generation; Second law analysis; DIFFUSIVE NATURAL-CONVECTION; HEAT-TRANSFER COEFFICIENT; MASS-TRANSFER; NUMERICAL-SIMULATION; EXERGETIC ANALYSIS; ECONOMIC-ANALYSIS; ENERGY; PRODUCTIVITY; PERFORMANCE; FLOW;
D O I
10.5004/dwt.2018.21925
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Computational fluid dynamics (CFD) simulation of fluid flow in weir-type cascade solar stills with different geometries has been presented in this paper. The results of CFD simulation were also used to estimate local entropy generation inside the weir-type solar stills. The results showed that maximum water production was achieved with 7, 8 and 10 steps when the step height was 2 cm. In addition, considering number of steps and various steps heights, the case with six steps of 3.5 cm height was found to be the best geometry for the investigated solar still. Moreover, the results of the simulation show that the number of recirculating zones and their regularity are the main parameters affecting the productivity of a weir-type cascade solar still. Contours of isotherms, vapor mass fraction, streamlines and local entropy generation have been presented in order to demonstrate their contribution to the behavior of the investigated solar still. Furthermore, the results of second law analysis showed that the most entropy generation occurred near the glass and the water surface, as well as at the tip of the stairs. This entropy generation was mainly due to the heat and mass transfer phenomena and the fluid friction.
引用
收藏
页码:15 / 27
页数:13
相关论文
共 60 条
[1]   On the characteristics of multistage evacuated solar distillation [J].
Ahmed, M. I. ;
Hrairi, M. ;
Ismail, A. F. .
RENEWABLE ENERGY, 2009, 34 (06) :1471-1478
[2]   Numerical study of heat and mass transfer in a solar still device: Effect of the glass cover [J].
Alvarado-Juarez, R. ;
Xaman, J. ;
Alvarez, G. ;
Hernandez-Lopez, I. .
DESALINATION, 2015, 359 :200-211
[3]   Numerical study of conjugate heat and mass transfer in a solar still device [J].
Alvarado-Juarez, R. ;
Alvarez, G. ;
Xaman, J. ;
Hernandez-Lopez, I. .
DESALINATION, 2013, 325 :84-94
[4]  
[Anonymous], 1982, Entropy Generation through heat and fluid flow
[5]  
[Anonymous], 1980, Numerical heat transfer and fluid flow
[6]  
[Anonymous], J MODEL ENG
[7]   Exergy analysis of solar desalination still combined with heat storage system using phase change material (PCM) [J].
Asbik, Mohamed ;
Ansari, Omar ;
Bah, Abdellah ;
Zari, Nadia ;
Mimet, Abdelaziz ;
El-Ghetany, Hamdy .
DESALINATION, 2016, 381 :26-37
[8]   NUMERICAL STUDY OF DOUBLE-DIFFUSIVE NATURAL-CONVECTION IN A SQUARE CAVITY [J].
BEGHEIN, C ;
HAGHIGHAT, F ;
ALLARD, F .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1992, 35 (04) :833-846
[10]  
Cengel Y.A., 2002, SEA, V1000, P8862