Methyl methacrylate in external fixation of supracondylar humerus fractures: An experimental study

被引:1
|
作者
Gulec, Ali [1 ]
Acar, Mehmet Ali [1 ]
Aydin, Bahattin Kerem [1 ]
Demir, Teyfik [2 ]
Ozkaya, Mustafa [3 ]
机构
[1] Selcuk Univ, Fac Med, Dept Orthopaed & Traumatol, TR-42030 Konya, Turkey
[2] TOBB Univ Econ & Technol, Fac Engn, Dept Mech Engn, Ankara, Turkey
[3] KTO Karatay Univ, Fac Engn, Dept Mech Engn, Konya, Turkey
关键词
Methyl methacrylate; external fixation; distal humerus fractures; DISTAL HUMERUS; CHILDREN; CONFIGURATIONS; EPIDEMIOLOGY; MANAGEMENT; ELBOW;
D O I
10.1177/0954411918796533
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Supracondylar humerus fractures are common fractures around the elbow. Open fractures, comminuted metaphyseal fractures and also fractures with bone loss may need to be treated with external fixators. The aim of this study is to compare two different external fixators, tubular external fixators and polymethyl methacrylate with K wires external fixators, with regard to stiffness and stability for metaphyseal-diaphyseal osteotomies of distal humerus close to the joint. Six matched pairs (24 specimens) of second-generation sawbone humerus were prepared in a standard fashion to create a metaphyseal fracture, 5cm proximal to the distal joint line of humerus and were randomly divided into two groups of 12 specimens each. Each sawbone humerus was osteotomized transversely at the mid-olecranon fossa with a 2-mm oscillating saw to simulate a Gartland type III fracture. The osteotomy was then reduced and stabilized using two different external fixation methods: carbon tubular external fixator with Schanz screws and methyl methacrylate with multiple K wires. Three-point bending and torsion tests were performed on the specimens. Bending and torsional stiffness of specimens were obtained for the fixation methods. According to the results of the study, the methyl methacrylate group has provided higher stiffness than classical tubular fixator with Schanz screws in three-point bending test (7.79 +/- 2.33N/mm vs 3.78 +/- 1.18N/mm, p=0.006). The methyl methacrylate group also showed better stiffness in torsion test (0.12 +/- 0.042Nm/degrees vs 0.067 +/- 0.013Nm/degrees, p=0.02). We determined for the first time in literature that external fixation with methyl methacrylate was significantly superior to the classical tubular external fixator with Schanz screws with regard to stiffness and stability under three-point bending and torsional loads. Moreover, methyl methacrylate is inexpensive and easily applied.
引用
收藏
页码:1025 / 1029
页数:5
相关论文
共 50 条
  • [1] Agreement on fixation of pediatric supracondylar humerus fractures
    Spierenburg, Willemijn
    Dekker, Anne Britt E.
    Doornberg, Job N.
    Krijnen, Pieta
    van den Bekerom, Michel P. J.
    Schipper, Inger B.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2022, 48 (05) : 4277 - 4282
  • [2] Supracondylar Humerus Fractures
    Clair, J. Benjamin St.
    Schreiber, Verena M.
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2019, 29 (01) : 11 - 16
  • [3] COMPARISON OF TWO METHODS OF FIXATION OF SUPRACONDYLAR FRACTURES OF THE HUMERUS IN CHILDREN
    Natalin, Henrique Melo
    da Silva, Jessica Colamarino Sessa
    Volpon, Jose Batista
    ACTA ORTOPEDICA BRASILEIRA, 2021, 29 (05): : 263 - 267
  • [4] Strategies in the Treatment of Supracondylar Fractures of the Humerus in Children - Proven and Controversial
    Lehner, M.
    Schuster, B.
    Dietz, H-G.
    ZENTRALBLATT FUR CHIRURGIE, 2014, 139 (06): : 613 - 620
  • [5] Standardizing a Postoperative Protocol for Supracondylar Humerus Fractures
    Heyer, Jessica H.
    Anari, Jason B.
    Baldwin, Keith D.
    Arkader, Alexandre
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2022, 42 (02) : E103 - E108
  • [6] External fixation in the treatment of supracondylar femoral fractures
    Galante, VN
    Moretti, B
    Conserva, V
    Battista, G
    Patella, V
    Simone, C
    KNEE, 1999, 6 (02) : 137 - 142
  • [7] Supracondylar fractures of the femur treated by external fixation
    Marsh, JL
    Jansen, H
    Yoong, HK
    Found, EM
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (06) : 405 - 410
  • [8] Pitfalls of lateral external fixation for supracondylar humeral fractures in children
    M. Horst
    S. Altermatt
    D. M. Weber
    R. Weil
    L. E. Ramseier
    European Journal of Trauma and Emergency Surgery, 2011, 37 : 405 - 410
  • [9] External fixation and Kirschner wires in the treatment of paediatric displaced supracondylar femur fractures
    Li, Jin
    Yue, Changjie
    Wang, Hai-Qiang
    Guo, Xikai
    Chen, Kailei
    Ma, Jiewen
    Wang, Jing
    Tang, Xin
    JOURNAL OF CHILDRENS ORTHOPAEDICS, 2020, 14 (04) : 293 - 298
  • [10] Pitfalls of lateral external fixation for supracondylar humeral fractures in children
    Horst, M.
    Altermatt, S.
    Weber, D. M.
    Weil, R.
    Ramseier, L. E.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2011, 37 (04) : 405 - 410